Jaipur
+918529833535

'weekly hi lo summaries'

Items tagged with 'weekly hi lo summaries'

product image
Glucometer

The CONTOUR®PLUS system helps you test with ease and uses remarkably accurate CONTOUR®PLUS test strips Accurate — Delivers closer to lab results, so you can test with confidence No Coding™ and no setup requirements — ready to test right out of the box Second-Chance™ sampling — tells you when to apply more blood if the first sample was not enough Simple and customisable features to meet your testing needs, from basic to more in-depth. For any question related to Ascensia Diabetes Care products, please contact the distributor in your country listed under Contacts Personalized HI/LO target ranges Weekly HI/LO summaries to give a snapshot of your current blood glucose status 7-, 14-, and 30-day averages Meal markers to help you understand how food impacts your blood glucose Audible reminders to help you remember to test after eating 480 test memory

Send Message
product image
BP Apparatus

Our company is widely appreciated for providing Halogen Lamps to clients. Halogen Lamps is ideal for various industrial, commercial sectors and many more places. Accessible with us in numerous specifications, this offered product range is broadly in demand. To add, our ability to customize these as per the specialized desires of our patrons has gifted us massive appreciation in this country. Because of the flexibility, exactness, reliability, and timeliness of our team members, these are immensely in demand and applauded all over the country. Features: Finely finished Precisely designed Fully checked Product Details: Brand Swastik IP Rating IP66 Lighting Color Warm White Type Halogen lamp Color Transparent White Voltage 220 V

Send Message
product image
Glucometer

SD CodeFree A representative model of of SD BIOSENSOR which is easy to use and provides accurate results without the need for coding. The SD Codefree Blood Glucose Meter is a compact, hand-held, and easy-to-read monitor that stores up to 500 test results. It provides an accurate picture of your blood glucose level at the time of the test from a small droplet of blood. Specification Enzyme Glucose Oxidase biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Specimen volume 5 sec Sample Volume 0.9 µl Hematocrit 20 - 60% Unit mg/dL Memory Up to 500 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC110 SD CodeFree™ Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS11 SD CodeFree™ Blood Glucose Test Strip SD CodeFree™ Test Strip (25EA x 2 bottle)

Send Message
product image
Urinalysis

Product Description: This is a continuous loading system for automatic movement, timing, measurement & evaluation of urine test strips. Product Features: High Throughput - High Memory Capacity Easy operation via touchscreen Product Application: Automated reading of Urine test strips that avoids subjective errors in visual reading Technical Specifications: System: Continuous loading Semi-automated Urine test strip analyzer Type: Reflectance photometer Measuring System: Wavelengths – 460 nm, 530 nm, 610 nm Memory: 1000 results Throughput: 400 tests /hr User interface: LCD touchscreen (800 x 480 pixel) Printer: Built-in Thermal Printer Certificates: CE Physical Dimensions: 300 x 287 x 148 mm Weight : 3.2 Kg Test Strips: DekaPHAN Laura & MicroalbuPHAN Laura Parameters: Specific Gravity, Leucocytes, Nitrite, pH, Protein, Glucose, Ketone, Urobilinogen, Bilirubin, Blood & Microalbumin, Creatinine Optical QC: Grey QC strip System Interface: Communication via RS232 & USB port Host Protocol: Uni-directional Sample Identification: Sample ID via keyboard entry, barcode reader Power source: AC 100-240V/50-60 Hz Power consumption: ≤45 W

Send Message
product image
HEMOGLOBIN METER

Mispa HbX Portable Haemoglobin Analyzer Overview Mispa HbX , Smart Haemoglobin analyzer is a symbol of advanced point of care equipment with modern technology and convenience, designed to deliver high accuracy, quality results with least turnaround time and low maintenance. Best in Class Hemoglobin Meter Mispa HbX, the Smart Haemoglobin Analyzer, is the best example of an advanced point-of-care hemoglobin reader with modern technology. It is easy to use and designed to deliver accurate, high-quality results with the shortest turnaround time and minimal maintenance. This digital Hb meter is one of the best hemoglobin meters available. Working of A Hemoglobin Meter or a hemoglobin reader A hemoglobin meter or a hemoglobin reader measures the amounts of hemoglobin and hematocrit in whole blood. Hemoglobin tests are typically performed to determine the RBC count, the severity of anemia, hematocrit, and other haematological factors. It is widely utilized during blood donations and key decisions such as blood transfusions. HbX works with Spectrophotometry Scattered compensation Technology for accurate and quick results Results will be retrieved with in less than 3 seconds after sample reading starts Sample Required: 7ul Capillary or Venous blood Three Step procedure makes HbX more convenient to use CV value will be less than 1.5 % 6 Hours Battery Backup makes it a hand equipment 2000 Data storage capacity Micro Fluidic cuvettes with 2 year Shelf life

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ SAA Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of serum amyloid A (SAA) in human whole blood, serum or plasma. This test is used as an aid to assist in the diagnosis of infection and inflammation. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ NGAL Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Neutrophil Gelatinase-Associated Lipocalin (NGAL) concentration in human urine. The test is used as an aid for the diagnosis of kidney injuries. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ β2-MG Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of β2-MG (Beta-2-Microglobulin) concentration in human plasma, serum or whole blood. The test is used as an aid for the diagnosis of renal disease. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Myo Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Myoglobin in human whole blood, serum or plasma. This test is used as an aid to assist in the diagnosis of acute myocardial infarction (AMI). STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for
weekly hi lo summaries?