product image
Immunology Analyzer

Product Description: The LisaScan EM Microplate Reader is an economical, compact and versatile 8 channel ELISA reader which can be adapted to various ELISA applications. It is India’s largest selling automated microplate ELISA reader Product Features: Wavelength Range: 400 to 750nm with a dynamic measurement range of 0.0 to 4.0 O.D 100 user-programmable test storage Inbuilt thermal printer for reports & graphs Auto self-check on start-up & external printer connectivity Compatible to various plate geometrics-96 well microplates ( Flat, U & V bottom) Wavelength selection: Monochromatic, bi-chromatic & multi-chromatic* Reading time 8 sec. for single wavelength using 8-channel optics User-friendly inbuilt operation software with 7000 sample test results storage User interface: High Resolution LCD display with 20 Keys Rugged waterproof & membrane panel Computer linked ELISA data management software - Eli-LIMS* CE marked Inbuilt shaking facility,Three Linear Speeds - Low, Medium and Fast Reports can be printed using internal thermal or external printer No need of manual calculations and documentation Documentation ease – Reports can even be stored using optional Eli-LIMS software Computer can be connected Extensive ELISA data management Product Applications: ELISA System type: Open System Plate types: 96 well plates Wells Type: U, V and Flat bottom wells Operating Modes: Absorbance Quantitative Qualitative Semi-Quantitative Kinetic Mode Measurement Modes: Continuous / Step Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set Wavelength Selection: Monochromatic Bi-Chromatic Multi-Chromatic* (Maximum 4) Calculation Modes: Non-linear Standard Cut-off Index Formula Column Subtraction Linear Regression Point to Point Cubic Spline Linear – Log Blank Options: Blank, Control, Assay Validation equations Against Air, Well Plate, Column, Column-mean Row, Row mean Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters Test Programs: 100 totally “open” Test Programs Photometer: Measuring system: 8-Channel optical system Lamp Source: Tungsten Halogen with Lamp saver function Wavelength Range: 400 to 750 nm Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass Dynamic Range: 0.0 ~4.0 OD Photometric accuracy: < 1% at 2.5 OD at 450 nm Photometric resolution: 0.001 OD Linearity: <1% at 2.5 OD at 450 nm Measurement Time: SPEED : 8 Seconds single wavelength NORMAL : 17 Seconds single wavelength Display: High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm Keyboard: Rugged waterproof & membrane panel PC Communication: USB Based Protocol compatible with Eli-LIMS and TNW Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor). Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves. Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored. Lab name in Print-out Lab name in Display Collated reports Print-out of Normal Range along with the result (on external printer only). Graphs can be printed on Thermal Printer Sorted by: Date I.D. Both by Date & I.D. Test Plate ID Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad. Operating Temperature: 20˚ C to 40˚ C Storage Temperature: -10˚ C to 50˚ C Humidity: Max. 80% RH, non- condensing Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter 115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified) Dimension: 502 mm X 369 mm X 216 mm Weight: 7 Kg

Send Message
product image
Clinical Chemistry

The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 9000 Assays Clinical Chemistry Power Supply 230 V Reaction Cuvette Reusable Cuvette Storage 300000 Samples Features Seamless Integration Usage/Application Lab Wavelength 5000nm Number Of Reagent Positions 4 Weight 130kg Frequency 50 Hertz Power 45 Watt Product Description The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Features Maximize laboratory efficiency Integration: Optimize your lab’s customized arrangement with better automation system Efficiency: High-throughput chemistry and immunology modules for longer walk-away time Reliability: Ingenious and comprehensive analytic system provides reliable and accurate results Easy operation: Fully automated design,user-friendly operation interface and intelligent software function

Send Message
product image
Laboratory Usage

We are the Leading Supplier of Abbe Refractometer Rajdhani. In the Abbe'' refractometer the liquid sample is sandwiched into a thin layer between an illuminating prism and a refracting prism. The refracting prism is made of a glass with a high refractive index (e.g., 1.75) and the refractometer is designed to be used with samples having a refractive index smaller than that of the refracting prism. A light source is projected through the illuminating prism, the bottom surface of which is ground (i.e., roughened like a ground-glass joint), so each point on this surface can be thought of as generating light rays traveling in all directions. A detector placed on the back side of the refracting prism would show a light and a dark region. Over a century after Abbe''s work, the usefulness and precision of refractometers has improved, although their principle of operation has changed very little. They are also possibly the easiest device to use for measuring the refractive index of solid samples, such as glass, plastics, and polymer films. Some modern Abbe refractometers use a digital display for measurement, eliminating the need for discerning between small graduations. However, the user still has to adjust the view to get a final reading. The first truly digital laboratory refractometers began appearing in the late 1970s and early 1980s, and no longer depended on the user''s eye to determine the reading. They still required the use of circulating water baths to control instrument and fluid temperature. They did, however, have the ability to electronically compensate for the temperature differences of many fluids where there is a known concentration-to-refractive-index conversion. Most digital laboratory refractometers, while much more accurate and versatile than their analog Abbe counterparts, are incapable of readings on solid samples. In the late 1990s, Abbe refractometers became available with the capability of measurements at wavelengths other than the standard 589 nanometers. These instruments use special filters to reach the desired wavelength, and can extend measurements well into the near infrared (though a special viewer is required to see the infrared rays). Multi-wavelength Abbe refractometers can be used to easily determine a sample''s Abbe number.

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 190-1100 nm Mobility Portable Brand Swastik Color Black, White, Yellow Material PVC Wavelength Accuracy +/- 0.5 Nm Display LED As an esteemed company, we are providing our clients an exclusive spectrum of Spectrophometer. An offered spectrophotometer is developed utilizing supreme class components and leading technology in adherence with the set norms of the industry. This spectrophotometer is well tested on diverse aspects so as to supply a flawless range to customers. We offer this spectrophotometer in various specifications to choose from. Our spectrophotometer is acknowledged among customers for its optimum quality. Features: Precisely engineered Easy to handle Enhanced durability

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 190-1100 nm Optical System Double Beam Spectral Bandwidth 1 nm Wavelength Accuracy 0.1 nm Wavelength Repeatability 0.1 nm Photometric Accuracy 0.3 % T Photometric Range 0-200 % T, -0.3 - 3.0 A, 0-9999 C Photometric Repeatability 0.2 % T Stray Light Less than equal to 0.05%T Stability 0.001 A/h Detector Silicon Photodiode Lamp Type Deuterium Lamp, Tungsten Halogen Lamp Baseline Flatness 0.001 A Noise 0.001 A Data Output Port USB Port Display Graphic LCD (320*240 Dots) Dimensions 630 x 430 x 206 mm Printer Port Parallel Port Weight 26 kg We are the leading manufacturer of a wide range o These products are UV-VIS Spectrophotometer easy to operate and highly appreciated for its durability. Specifications: Wavelength Range 190-1100 nm Mode Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics Scanning Speed Fast / Medium / Slow Wavelength Accuracy 0.1 nm Bandwidth 1 nm Wavelength Reproducibility 0.1 nm Photometric Display Range 0-200 % T, -0.3 - 3.0 A, 0-9999 C Photometric Accuracy 0.3 % T Photometric Repeatability 0.2 % T Stability 0.001A/h @ 500 nm Baseline Flatness 0.001 A Noise 0.001A Stray Light < 0.05% T @ 220nm, 360 nm) Data Output Port USB Printer Port Parallel Port Display Graphic LCD (320*240 Dots) Lamps Deuterium Lamp & Tungsten Halogen Lamp Detector Silicon Photodiode Dimensions(L*W*H) 630 x 430 x 206 mm Net Weight 26 Kg

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 195-1000 nm Display Digital Brand Thermo Sample Compartment 4 Position Cuvette Holder Interface RS-232C Packaging Type Carton Box We are the leading manufacturer of a wide range o These products are UV-VIS Spectrophotometer easy to operate and highly appreciated for its durability. Applications: Microprocessor based UVVIS Spectrophotometer is an analytical instrument that is commonly used in various physics & chemical laboratories to make qualitative and quantitative analysis of under focus materials in the presence of ultraviolet and visible spectrum range. It is widely used in fields such as clinical examination, medicine, petro-chemical industry, biochemistry, bio technology, quality control and environmental protection. It is also used in study at molecular level in of DNA and Proteins. It is non-destructive and easy to use in nature. Salient Attributes of the product: Cover 195 to 1000 nm 4 Position Cuvette Holder RS-232C Computer Interface High wavelength Precision Compact & Good Looking Shape Highly Accurate & Stable

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range* <0.5%T over entire wavelength range* ,

Send Message