Jaipur
+918529833535

'vitamin c'

Items tagged with 'vitamin c'

product image
immunoassayReagents

INTENDED USE The Finecare™ Vitamin D Rapid Quantitative Test along with Finecare™ FIA Meter is a fluorescence immunoassay quantitative determination of total 25(OH) D2/D3 level in human serum or plasma. Results are to be used in conjunction with other clinical and laboratory data to assist the clinician in the assessment of vitamin D sufficiency. STORAGE AND STABILITY 1. Store at 4°C~30°C up to the expiration date. 2. The solid marker bottle can be stored at 2°C~8°C for 28 days after being reconstituted. 3. Do not remove the device from the pouch until ready to use. The Test Cartridges should be used within 1 hour once opened.

Send Message
product image
Rapid Test

Buy AccuTest Vitamin D Rapid Card Test (10 Tests) Online from Accurex. The Vitamin D test kit consists of 25 AccuTest Vitamin D individually packed test, devices in foil pouches, 25 pipettes for collecting 10 ul of whole blood, 25 lancets, 1 Buffer Vial (Buffer 5 mL) with stabilizers and, thimerosal, 1 Package Insert. Vitamin D Fast test kit is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This Vitamin D test provides a preliminary screening test result. INTENDED USE AccuTest Vitamin D is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This assay provides only a preliminary screening test result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. The performance characteristics of this assay have not been established in a pediatric population. PRINCIPLE AccuTest Vitamin D is based on the principle of a competitive enzyme immunoassay. The assay is based on the competition for 25-OH Vitamin D present in blood/serum sample and Vitamin D present on the test line for fixed number of antibody-gold conjugate. Depending upon the concentration of Vitamin D in blood/serum, there will be free antibody-gold conjugate molecules that will bind to Vitamin D on the test strip and will show a colored line in the test line zone. A control line is present in the test window to work as procedural control. PRECAUTIONS 1. For in vitro diagnostic use only. 2. The test is designed for use with human blood/serum only. 3. Reagents must be at room temperature (8⁰C – 30 ⁰C). 4. Do not use if test device packaging is open or damaged. 5. Do not use the product beyond expiration date. 6. Handle all specimens as potentially infectious. Proper handling and disposal methods should be used according to good laboratory practices. 7. Read test results for 10 minutes as required. Results may deteriorate and may not be consistent after 10 minutes. 8. In order to avoid variable results, mix the blood sample thoroughly. 9. A serum sample subjected to repeated freeze thaw cycles may give variable results Direction for Use PROCEDURE 1. Remove the cassette from the sealed pouch and place it on a hard flat surface with the view window facing up (use the cassette as soon as possible). 2. Using a micropipette, add 10 µl of whole blood or 5ul of serum sample directly into the rectangular specimen well (marked with Red drop) of the cassette. 3. Add 3 full drops of Buffer into the square buffer well of the cassette (Do not move the cassette after addition of buffer). 4. Let the cassette sit for 10 minutes and read your results immediately. Results may deteriorate after the 10 minute mark. Other Info STORAGE AND STABILITY The test device should be stored at 8 ⁰C – 30 ⁰C and will be stable until the expiration date stated on the package. The product is humidity sensitive and should be used immediately after being open. INTERPRETATION OF RESULTS Match the color of the test line with the chart provided.

Send Message
product image
Biochemistry Analyzer

Yumizen CA40 Semi-automated Clinical Chemistry Analyzer: Yumizen CA40 is a semi-automated Clinical Chemistry analyzer with facility to perform Chemistry, Immunoturbidimetry and Coagulation Tests (PT & APTT). It is an ideal solution for small laboratories with the facility to perform a wide range of biochemical tests. Specification:- Semi-automated Clinical Chemistry analyzer with coagulation tests capacity (PT & APTT) 8 incubation positions for chemistry tests and 5 positions for coagulation tests 8-inch colored touch screen display Tri-level Quality Control with Levey-Jennings chart 6 filters with additional 2 open positions Show less

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
immunoassayReagents

Cortisol Rapid Quantitative Test The Finecare™ Cortisol Rapid Quantitative Test is a fluorescence immunoassay for quantitative determination of Cortisol in human serum, plasma or whole blood. The test is used as an aid to the screening of adrenal dysfunction and assessment of the treatment effect. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the test cartridge from the pouch until use. The test cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Ferritin Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of Ferritin in human whole blood, serum or plasma. The test is used as an aid to the assessment of iron deficiency anemia. STORAGE AND STABILITY 1. Store the test kit at 4 ~30℃ up to the expiration date printed on the package. 2. Do not remove the Test Cartridge from the pouch until ready to use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ S100β Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of S100β in human serum, plasma or whole blood. The test is used as an aid to the assessment of the level of cerebral injury. STORAGE AND STABILITY 1. Store the test kit at 4 ~ 30 ℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for