Jaipur
+918529833535

'vacuum'

Items tagged with 'vacuum'

product image
Immunology Analyzer

Product Description: Erba Lisa Wash II is a simple easy to Operate and use ELISA Plate Washer, Suitable for all ELISA applications. Programmable features like, dispense pressure, Single/double aspiration, Horizontal & Vertical adjustments ensures complete control on washing efficiency Product Features: Fully automated, easy operating system and friendly software with large-screen display 50 user programmable protocols to customize washing Easily removable 8- or 12-way manifolds Liquid level detection and alert function Low residual volume: <3 µl Soak time programmable up to 24 hrs. Compatible for flat-bottom, U and V bottom type microplates or microstrip High-efficiency ELISA washing with automated monitoring of Vacuum. Choice of 2 wash buffer bottles, 1 distilled water & 1 waste container with sensor Dispense pressure and the volume adjustable, so as to reduce the air bubbles and ensure thorough Washing Waste-bottle sensor to detect high-waste liquid levels Standard aerosol protection cover Easy maintenance CE marked Product Applications: ELISA Wash Head: 8 and 12 head manifold compatible Wash Mode: Row and Plate Wash Row: 1-12 rows Flat Bottom Plate Type: 96 or 48 well plate or strip (Flat, U & V - bottom) Wash Programs: 50 Moving Cycle: up to 12 cycles Dispensing Volume: 50 - 3000μl in 50μl increments Dispensing Precision: < 2% at 350μl Prime Volume: 50 - 1000μl Aspiration Pressure: Automatic Soak Time: 0 – 24 Hrs Residual Volume: ≤ 2μl for V/ U bottom plates, and ≤ 3μl for per well Flat bottom plates Nos. of Bottles: 2 wash, 1 Rinse/DI, 1 waste with level sensor, 2L each User Interface: 5 Inch LCD (90 x 53 mm), with Keypad Bottle Capacity: > 2 L Operating Environment Power Supply: AC 220 V/ 110 V, 50/60 Hz Input Power : < 80VA Operating Temperature: 10°C - 30°C Relative Humidity: Up to 95% relative humidity without condensation Storage Temperature: -10°C - 40°C Weight: 9.5 Kg Dimension: 710 mm x 530 mm x 380 mm

Send Message
product image
Clinical Chemistry

XL 1000 with the throughput of upto 1040 tests per hour is the ideal instrument for centralizing the complete biochemistry testing load on a single fully automated platform. Increased walk away productivity and less human intervention make it an ideal analyzer for large laboratories. Equipped with all necessary advanced features that one expects from a high end fully automated chemistry analyzer; sample loading through rack system, cooled calibrator and control carousel, low reading volume of 150 µL, diffraction grating with 15 wavelengths from 340 nm to 800 nm and user-friendly software, to optimize and reliably run the daily lab workload. XL 1000 is a "dream come true" workhorse for laboratories with increased workload and the perfect solution. Fully Automatic, Discrete, Patient prioritized, Random Access Clinical Chemistry Analyzer with throughput of 1040 tests/hour 3 Reagent capabilities 147 long life Hard Glass cuvettes Separate Carousel for STAT samples Onboard refrigeration for reagents Extensive database for storing patient data and Q.C. results Primary tube sampling with bar code identification 9 stage laundry for cuvettes wash 150 samples can be loaded at a time through rack system System Discrete, open, automated, random access, patient prioritized, 1/2/3 reagent system DISPENSING OF SAMPLES AND REAGENTS Sample volume: 2-60 µl (0.1 µl step), 70 µl with ISE Reagent volume: 120 µl – 550 µl 3 dispensing probes ( R1, R2/R3) equipped with liquid -level sensor and crash detector Auto-dilution of samples and calibrators Clot detection Samples Serum, urine, plasma, CSF and other Economy Minimum reaction volume: 180 µl Reusable reaction cuvettes Mixing System 2 independent stirrers 3 user selectable mixing speeds Quality Control 4 levels of control material can be used Levey-Jennigs graphs Twin Plot diagrams for monitoring of systematic and random error Reaction unit with wash station 147 reusable hard glass cuvettes Possibility of replacement of individual cuvette Wash station – cuvette rinsing and drying in nine-step procedure Automatic cuvette blank measurement before analysis Sample Autoloader 23 racks 115 sample positions on automatic autoloader Primary tubes 5, 7 and 10 ml, vacuum system tubes Barcode reader for sample identification 2 Reagent trays With 43 cooled position each Barcode reader for reagent identification 20 ml, 50 ml reagent containers, 5 ml tube with adaptor Option to use one reagent for several test simultaneously Stat Tray 45 positions Can be used for blank, controls, STAT samples Software Convenient user interface Connection to LIS Programmable auto-start from sleep mode including automatic daily maintenance Statistical methods of processing results Data export in selected format Measurement Monitoring Colour indication of sample analysis Possibility of monitoring the reaction in real time Reagent volume monitoring Informative reports on ongoing analyzer status

Send Message

Still searching for
vacuum?