product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message
product image
Immunology Analyzer

Product Description: Erba Lisa Wash II is a simple easy to Operate and use ELISA Plate Washer, Suitable for all ELISA applications. Programmable features like, dispense pressure, Single/double aspiration, Horizontal & Vertical adjustments ensures complete control on washing efficiency Product Features: Fully automated, easy operating system and friendly software with large-screen display 50 user programmable protocols to customize washing Easily removable 8- or 12-way manifolds Liquid level detection and alert function Low residual volume: <3 µl Soak time programmable up to 24 hrs. Compatible for flat-bottom, U and V bottom type microplates or microstrip High-efficiency ELISA washing with automated monitoring of Vacuum. Choice of 2 wash buffer bottles, 1 distilled water & 1 waste container with sensor Dispense pressure and the volume adjustable, so as to reduce the air bubbles and ensure thorough Washing Waste-bottle sensor to detect high-waste liquid levels Standard aerosol protection cover Easy maintenance CE marked Product Applications: ELISA Wash Head: 8 and 12 head manifold compatible Wash Mode: Row and Plate Wash Row: 1-12 rows Flat Bottom Plate Type: 96 or 48 well plate or strip (Flat, U & V - bottom) Wash Programs: 50 Moving Cycle: up to 12 cycles Dispensing Volume: 50 - 3000μl in 50μl increments Dispensing Precision: < 2% at 350μl Prime Volume: 50 - 1000μl Aspiration Pressure: Automatic Soak Time: 0 – 24 Hrs Residual Volume: ≤ 2μl for V/ U bottom plates, and ≤ 3μl for per well Flat bottom plates Nos. of Bottles: 2 wash, 1 Rinse/DI, 1 waste with level sensor, 2L each User Interface: 5 Inch LCD (90 x 53 mm), with Keypad Bottle Capacity: > 2 L Operating Environment Power Supply: AC 220 V/ 110 V, 50/60 Hz Input Power : < 80VA Operating Temperature: 10°C - 30°C Relative Humidity: Up to 95% relative humidity without condensation Storage Temperature: -10°C - 40°C Weight: 9.5 Kg Dimension: 710 mm x 530 mm x 380 mm

Send Message
product image
Immunology Analyzer

Product Description: The LisaScan EM Microplate Reader is an economical, compact and versatile 8 channel ELISA reader which can be adapted to various ELISA applications. It is India’s largest selling automated microplate ELISA reader Product Features: Wavelength Range: 400 to 750nm with a dynamic measurement range of 0.0 to 4.0 O.D 100 user-programmable test storage Inbuilt thermal printer for reports & graphs Auto self-check on start-up & external printer connectivity Compatible to various plate geometrics-96 well microplates ( Flat, U & V bottom) Wavelength selection: Monochromatic, bi-chromatic & multi-chromatic* Reading time 8 sec. for single wavelength using 8-channel optics User-friendly inbuilt operation software with 7000 sample test results storage User interface: High Resolution LCD display with 20 Keys Rugged waterproof & membrane panel Computer linked ELISA data management software - Eli-LIMS* CE marked Inbuilt shaking facility,Three Linear Speeds - Low, Medium and Fast Reports can be printed using internal thermal or external printer No need of manual calculations and documentation Documentation ease – Reports can even be stored using optional Eli-LIMS software Computer can be connected Extensive ELISA data management Product Applications: ELISA System type: Open System Plate types: 96 well plates Wells Type: U, V and Flat bottom wells Operating Modes: Absorbance Quantitative Qualitative Semi-Quantitative Kinetic Mode Measurement Modes: Continuous / Step Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set Wavelength Selection: Monochromatic Bi-Chromatic Multi-Chromatic* (Maximum 4) Calculation Modes: Non-linear Standard Cut-off Index Formula Column Subtraction Linear Regression Point to Point Cubic Spline Linear – Log Blank Options: Blank, Control, Assay Validation equations Against Air, Well Plate, Column, Column-mean Row, Row mean Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters Test Programs: 100 totally “open” Test Programs Photometer: Measuring system: 8-Channel optical system Lamp Source: Tungsten Halogen with Lamp saver function Wavelength Range: 400 to 750 nm Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass Dynamic Range: 0.0 ~4.0 OD Photometric accuracy: < 1% at 2.5 OD at 450 nm Photometric resolution: 0.001 OD Linearity: <1% at 2.5 OD at 450 nm Measurement Time: SPEED : 8 Seconds single wavelength NORMAL : 17 Seconds single wavelength Display: High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm Keyboard: Rugged waterproof & membrane panel PC Communication: USB Based Protocol compatible with Eli-LIMS and TNW Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor). Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves. Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored. Lab name in Print-out Lab name in Display Collated reports Print-out of Normal Range along with the result (on external printer only). Graphs can be printed on Thermal Printer Sorted by: Date I.D. Both by Date & I.D. Test Plate ID Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad. Operating Temperature: 20˚ C to 40˚ C Storage Temperature: -10˚ C to 50˚ C Humidity: Max. 80% RH, non- condensing Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter 115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified) Dimension: 502 mm X 369 mm X 216 mm Weight: 7 Kg

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Vitamin D Rapid Quantitative Test along with Finecare™ FIA Meter is a fluorescence immunoassay quantitative determination of total 25(OH) D2/D3 level in human serum or plasma. Results are to be used in conjunction with other clinical and laboratory data to assist the clinician in the assessment of vitamin D sufficiency. STORAGE AND STABILITY 1. Store at 4°C~30°C up to the expiration date. 2. The solid marker bottle can be stored at 2°C~8°C for 28 days after being reconstituted. 3. Do not remove the device from the pouch until ready to use. The Test Cartridges should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

Cortisol Rapid Quantitative Test The Finecare™ Cortisol Rapid Quantitative Test is a fluorescence immunoassay for quantitative determination of Cortisol in human serum, plasma or whole blood. The test is used as an aid to the screening of adrenal dysfunction and assessment of the treatment effect. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the test cartridge from the pouch until use. The test cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Ferritin Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of Ferritin in human whole blood, serum or plasma. The test is used as an aid to the assessment of iron deficiency anemia. STORAGE AND STABILITY 1. Store the test kit at 4 ~30℃ up to the expiration date printed on the package. 2. Do not remove the Test Cartridge from the pouch until ready to use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ S100β Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of S100β in human serum, plasma or whole blood. The test is used as an aid to the assessment of the level of cerebral injury. STORAGE AND STABILITY 1. Store the test kit at 4 ~ 30 ℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.