Jaipur
+918529833535

'users'

Items tagged with 'users'

product image
Instruments

Operate with Ease In the modern busy clinical environment, ease of use is a fundamental requirement for all medical devices. With this in mind, the new SV600 ventilators enable clinicians to set and deliver ventilation therapies quickly and easily via the intelligent ergonomic design and flat user interface. PulmoSight TM Utilizes numerical and graphical displays to show real time resistance, compliance and the spontaneous breathing status. Combined with the dynamic short trend display clinicians are able to monitor and evaluate changes in the patient's pulmonary ventilation and initiate the appropriate therapies. User configurable UI The SV600 ventilators offer exceptional user flexibility. Users are able to configure frequently used parameter controls by making them quick access shortcut keys in the UI. Also the ventilation mode keys can be arranged in order of frequency of use. This enables you to customize device in your way making parameter adjustment easier and quicker. Graphic guidelines The new intuitive graphical display enables users to learn quickly how to navigate and locate mode and parameter controls, thereby reducing errors and improving efficiency. Minimal Maintenance Routine maintenance requires no tools. The new 'door design' means that no tools are required to perform regular routine maintenance of the oxygen sensors, water trap, fan dust filter, HEPA air intake dust filter, etc. This ensures your new device always remains clean and clutter free. Intelligent Decision Making Ventilation modes and decision-supporting tools like Intelligent Assistant are developed on the basis of clinical needs and professional guidelines to help medical personnel calmly make clinical decisions. An extensive range of ventilation modes Smart ventilation solution: AMV TM + IntelliCycle TM Emergency solution: CPRVTM Sequential treatment regimen: Non-invasive ventilation & high flow oxygen therapy Dual channel auxiliary pressure measurements Lung protection kit Expandable Capabilities Securing your devices future is reliant on being able to expand your devices capabilities by interacting or integrating new concepts and technologies. The new SV800 / SV600 ventilators allow just this. Continue the latest electronic software and hardware, your new device is ready to embrace new technological advancement with ease. Integrated neonatal module with tidal volumes as low as 2 ml Plug & Play modules , including SpO2, mainstream or sidestream CO2 Backup air supply in case of air supply failure Seamlessly connected to the hospitals clinical information system via the Mindray BeneLink solution or eGateway solution Brand Mindray Model Name/Number SV600 Patient Age Group Neonatal, Adult, Paediatric Mounting Type ICU Operating Type Automatic Display Full color 15.6 inch Resolution 1920x1080 pixel Compliance IEC 60601-1-2 for EMC

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Hematology

n large laboratories, rows of instruments are seen working tirelessly like miniature factories – only they produce not commodities but medical test results. Mindray CAL 8000 new-generation cellular automation line is one of them, but unlike a typical workhorse, it is intelligent. It is a highly automated workstation for smarter, faster, and more accurate cellular analysis. It can perform competently in the face of these challenges. The workstation can hold up to four units of BC-6800 automated hematology analyzer, which utilizes the advanced SF Cube technology and 3-D scatter grams to help doctors better differentiate blood cell populations and reveal abnormal cells undetectable by conventional techniques. With 125 CBC tests per hour per unit, BC-6800 brings the process rate of the workstation to 20–30 percent higher than other similar models, effectively alleviating laboratory's stress during the peak processing hours. On CAL 8000, the hematology analyzer, slide maker and stainer, CRP analyzer, and HbA1c analyzer are all integrated into one seamless production line through automated track modules and trolley. Simply by loading a single tube of blood sample onto the automation system, one can get all the test results. This innovative walk-away automation functionality has made possible the CBC+CRP+HbA1c testing all in one streamlined workstation for the first time in the industry. It offers a smart solution, or rather, a smart expert – the labX pert 2.0. It is a software that can automatically sort out the suspected samples for manual validation. The pathologist then decides if rerun or microscopic review is warranted based on their clinical experience. It avoids wasting slides and reduces extra work. Moreover, the onboard automated re-exam functionality also helps enhance work efficiency. The CMU software The touch screen is the “brain” of CAL 8000. It optimizes the distribution of workload between each analyzer unit and decides which sample requires a blood smear. It displays the status of each analyzer or SC-120 installed on CAL 8000 as well as the volume of balance reagent. This intuitive software can tell the users all necessary information of CAL 8000 at any given time. Consequently, the users spend less time operating CAL 8000 and can arrange their working schedule better. Multi “R” tests The CAL 8000 can automatically distribute the samples with “Repeat”, “Rerun” and “Reflex” criteria which are pre-defined by users.The re-exam criteria on CAL 8000 can be defined by many conditions, such as time, patient’s age, gender, department, etc. This helps minimize the number of blood smears. Special tube racks The special tube racks utilize different barcodes to differentiate specific testing purposes, such as “QC”, “Slide making & staining only” and “RET test only”. The special tube racks can carry the tubes to perform these specific functions in the simplest way.

Send Message
product image
Medical Equipment

With state-of-the-art screen technology, BeneVision N Series patient monitors deliver clear, multi-color, wide-format displays for users to capture and review information at a glance. With multi-touch operation, users can control the monitor and review patient data quickly and easily. BeneVision N Series provides the world's best monitoring technologies for you, with new applications being developed. Perfect hemodynamic monitoring solution, not only provides a variety of measurement methods, ICG, PiCCO, ScvO2, C.O., but also provides comprehensive analysis tool – HemoSight™. HemoSight™ focuses on hemodynamic treatment process, and provides appropriate tools for each stage. Advanced modular regional tissue oxygenation measurement -- INVOS rSO2. Volumetric capnography & metabolic measurement help to evaluate the adequacy of ventilation and determine the ventilator setting effectively, and improve the safety of weaning and extubation. Powerful Clinical Assistive Applications (CAAs) to support efficient decision making when time is critical. Each CAA focuses on major clinical workflow challenges that individual departments face. Solutions optimized for each point of care At every point of care, such as ICU, CCU, NICU, OR, PACU, ER, BeneVision N Series patient monitors always provide a suitable solution to meet your clinical needs for monitoring your patient's status anywhere, anytime, even on your way through mobile devices. With excellent transport solution, BeneVision N Series patient monitor brings a smooth workflow and safe data management through the entire care process. BeneVision takes less time to operate, and helps you understand the patient's variables quickly. With HL7,BeneVision N Series patient monitors can directly connect to the hospital clinical network.BeneVision N12 is capable of monitoring multiple parameters simultaneously both at bedside and during transport. IT structure designed for seamless connectivity Mindray patient monitoring system incorporates extensive network adaptability to integrate with the hospital's current network infrastructure, ensuring that critical data is on hand for clinical decision making - and is integrated with the patient record. Mindray's central station and eGateway further enhances the connectivity of BeneVision to your clinical world. Bedside devices data and other clinical systems data are shared to support your diagnosis and clinical decisions.

Send Message
product image
Laboratory Testing Analyzer

For smaller Laboratories Smaller, but with full functionality Compact size Full functions and performance in a compact size. *Size comparison with HA-8180V Accuracy HPLC technology provides accurate results-inluding detailed chromatogram. it will be shown in both IFCC and NGSP units. Cap-piercing method ADAMS Lite uses a cap-piercing method which enables the placement of capped blood samples. This not only reduces the workload but also helps protect lab technicians from infection. Easy-to-maintain No special tools are required for daily maintenance. Exchanged parts are hand-tightened, minimizing the workload of users. Specifications Measurement objects Whole blood or hemolysis sample Measured items Fast Mode: HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode: HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed). Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm/500 nm (Dual-wavelength colorimetry) Resolution 0.1% Ratio, 1 mmol/mol Measurement range HbA1c: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Processing speed Variant mode: 160 seconds/test Fast mode: 100 seconds/test Sample consumption Whole blood sample: Approximately 4µL Anemia sample: Approximately 8 µL Hemolysis sample: Approximately 350 µL Sample container Sample tube: (12.3 or 15 mm in outer diameter) × (75 to 100 mm in height) Sample cup: 500 µL Sample supply Piercing sampling Compatible rack type ARKRAY racks (for 5 samples) Operating environment Temperature: 10 - 30°C; Humidity: 20 - 80% RH (No condensation) Display 20 digits × 2 lines LCD Printer For use with 58-mm width thermal printer paper Number of measurement samples Maximum 10 samples Power requirements AC 100 - 240 V±10%, 50/60 Hz Dimensions 330 (W) × 515 (D) × 485 (H) mm (Not including protrusions, eluent packs and hemolysis washing solution bottle)

Send Message
product image
Rapid Test

Buy AccuTest Typhoid IgG/IgM Rapid Card Test (5 Tests) Online from Accurex. The Typhoid IgG/IgM Rapid Test is used for detection & differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood / serum / plasma. This Typhoid test is used as a screening test and as an aid in the diagnosis of infection with S. typhi. Salmonella typhi bacteria causes typhoid Typhoid fever, typhoid symptoms symptoms are likely to develop gradually – appearing one to three weeks after exposure to the disease. There are various typhoid treatment & typhoid vaccine which can be opted after the detetction of Typhoid. Typhoid fever is caused by S. typhi, a Gram-negative bacterium. Worldwide an estimated 17 million cases and 600,000 associated deaths occur annually. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi. Evidence of H. pylori infection also presents an increased risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gall bladder. The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test. In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen thus to aid in the determination of current or previous exposure to the S. typhi. PRINCIPLE The Typhoid IgG/IgM Rapid Test is a lateral flow immunochromatographic assay. The test cassette consists of: 1) a pink-purple colored conjugate pad containing recombinant S. typhi H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test region (Test line M and G) and a control region (control line). The test line ‘M’ is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, test line ‘G’ is pre-coated with monoclonal anti-human IgG for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody at test region ‘M’, forming a pink-purple line at ‘M’ region, indicating a S. typhi IgM positive test result. Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a pink-purple line at test region ‘G’, indicating a S. typhi IgG positive test result. Absence of any pink-purple line at test region (M and G) suggests a negative result. The test contains an internal control (control line) which should exhibit a pink-purple line of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test region. Otherwise, the test result is invalid and the specimen must be retested with another device. PRECAUTION 1. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results. 2. Do not open the sealed pouch, unless ready to conduct the assay. 3. Do not use expired devices. 4. Bring all reagents to room temperature (15°C-30°C) before use. 5. Do not use the components in any other type of test kit as a substitute for the components in this kit. 6. Do not use hemolized blood specimen for testing. Wear protective clothing and disposable gloves while handling the kit reagents and clinical specimens. Wash hands thoroughly after performing the test. 7. Users of this test should follow the US CDC Universal Precautions for prevention of transmission of HIV, HBV and other blood-borne pathogens. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents are being handled. 9. Dispose of all specimens and materials used to perform the test as biohazardous waste. 10. Handle the Negative and Positive Control in the same manner as patient specimens. 11. The testing results should be read within 15 minutes after a specimen is applied to the sample well or sample pad of the device. Read result after 15 minutes may give erroneous results. 12. Do not perform the test in a room with strong air flow, ie. an electric fan or strong air-conditioning. Other Info STORAGE AND STABILITY Typhoid IgG/IgM test card should be stored at 4-40°C. The card may be stored at room temperature but not exceeding 40°C in the original sealed pouch. The shelf life or expiry of the card is printed on Pouch as well as carton label. The test kit should be kept away from direct sunlight, moisture and heat.

Send Message
product image
Glycohemoglobin Analysis

Xpress A1c strips are used for a testing of quantitative determination of glycated hemoglobin(HBA1c) in human whole blood. It is used to monitor metabolic control in diabetic patients. it helps in diagnosis of the diabetes or pre-diabetes in adults. Buy Xpress A1c strips online (Pack of 25 Strips) – the best a1c test strips from Point of Care (POC) Range of Accurex HbA1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. The Xpress A1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. The Xpress A1c strips then needs to be inserted into Xpress A1c meter for hemoglobin measurement, The Xpress A1c meter measures the absorbance of whole blood at Hb isosbestic point. Xpress A1c meter uses two wavelengths of light to calculate Hemoglobin level, user level calibration is not required. How to use: Step 1: Wash hands using soap and warm water. Rinse and dry thoroughly. Step 2: Turn on the meter by pressing-releasing the power button. Step 3: Remove an Xpress A1c strip from the vial. Step 4: Prick a finger to obtain a blood sample. Step 5: Touch and hold the drop of blood to the pointed edge of the Xpress A1c strip. The blood is drawn into the Xpress A1c strip by capillary action Step 6: Once the blood fills the Xpress A1c strip chamber. Insert the Xpress A1c strip into the Xpress A1c meter. Step 7: Your Hemoglobin result will appear on the display window. Step 8: Remove the Xpress A1c strip from the meter and discard it. The meter will automatically turn off or long-press the power button to turn off. The Xpress A1c strips are used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. is used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes.Features: Sample Type: Whole Blood/EDTA Blood/Capillary Blood Measuring Range: 0 to 25 g/dl Temperature: 0°C-50°C Storage Temperature: Room Temperature Expiry: Long Expiry(min 02 yrs) Pack Size: 25 Test/Vial LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message

Still searching for
users?