Jaipur
+918529833535

'u s cdc'

Items tagged with 'u s cdc'

product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Dengue IgG/IgM 3.0 Combo Rapid Test is a lateral flow immunoassay for the simultaneous detection and differentiation of IgG and IgM anti–dengue virus (DEN1, 2, 3 and 4) in human serum, plasma or whole blood. Utilizes recombinant chimeric dengue virus licensed from the US CDC Detects all four dengue serotypes IgM detection indicates recent infection IgG detection indicates recent or previous infections Individually sealed foil pouches containing: One cassette device One desiccant 5 µL capillary tubes Sample diluent (REF SB-R0061, 5 mL/bottle) One package insert (instruction for use)Individually sealed foil pouches containing: One cassette device One desiccant 5 µL capillary tubes Sample diluent (REF SB-R0061, 5 mL/bottle) One package insert (instruction for use)Individually sealed foil pouches containing: One cassette device One desiccant 5 µL capillary tubes Sample diluent (REF SB-R0061, 5 mL/bottle) One package insert (instruction for use)Individually sealed foil pouches containing: One cassette device One desiccant 5 µL capillary tubes Sample diluent (REF SB-R0061, 5 mL/bottle) One package insert (instruction for use)Individually sealed foil pouches containing: One cassette device One desiccant 5 µL capillary tubes Sample diluent (REF SB-R0061, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Dengue Case Report Dengue Info for Health Care Practitioners Dengue Training Presentation Flyer Insert Poster U.S. CDC Dengue Homepage : (Clinical Guidelines, Clinical Management Tools, etc) WHO: Health Topic for Dengue

Send Message
product image
Rapid Test

The OnSite HIV 1/2 Ab Plus Combo Rapid Test is a lateral flow immunoassay for the simultaneous detection and differentiation of HIV-1 and HIV-2 antibodies (IgG, IgM, IgA) in human serum, plasma or whole blood. 3rd Generation, double-antigen based test to increase the sensitivity in early detection Requires only 20 µL of specimen Use serum, plasma or whole blood Results available within 15 minutes to allow prompt action to be taken at the point of care Performance validated with BBI low titre panel and Chinese FDA HIV Ab panel Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (20 uL) Sample diluent (REF SB-R0011, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance Flyer Inserts TB-HIV Rapid Test Presentation U.S. CDC HIV Homepage: About HIV WHO: Health Topic for HIV U.S. CDC HIV Testing 101

Send Message
product image
Rapid Test

Buy AccuTest Typhoid IgG/IgM Rapid Card Test (5 Tests) Online from Accurex. The Typhoid IgG/IgM Rapid Test is used for detection & differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood / serum / plasma. This Typhoid test is used as a screening test and as an aid in the diagnosis of infection with S. typhi. Salmonella typhi bacteria causes typhoid Typhoid fever, typhoid symptoms symptoms are likely to develop gradually – appearing one to three weeks after exposure to the disease. There are various typhoid treatment & typhoid vaccine which can be opted after the detetction of Typhoid. Typhoid fever is caused by S. typhi, a Gram-negative bacterium. Worldwide an estimated 17 million cases and 600,000 associated deaths occur annually. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi. Evidence of H. pylori infection also presents an increased risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gall bladder. The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test. In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen thus to aid in the determination of current or previous exposure to the S. typhi. PRINCIPLE The Typhoid IgG/IgM Rapid Test is a lateral flow immunochromatographic assay. The test cassette consists of: 1) a pink-purple colored conjugate pad containing recombinant S. typhi H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test region (Test line M and G) and a control region (control line). The test line ‘M’ is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, test line ‘G’ is pre-coated with monoclonal anti-human IgG for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody at test region ‘M’, forming a pink-purple line at ‘M’ region, indicating a S. typhi IgM positive test result. Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a pink-purple line at test region ‘G’, indicating a S. typhi IgG positive test result. Absence of any pink-purple line at test region (M and G) suggests a negative result. The test contains an internal control (control line) which should exhibit a pink-purple line of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test region. Otherwise, the test result is invalid and the specimen must be retested with another device. PRECAUTION 1. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results. 2. Do not open the sealed pouch, unless ready to conduct the assay. 3. Do not use expired devices. 4. Bring all reagents to room temperature (15°C-30°C) before use. 5. Do not use the components in any other type of test kit as a substitute for the components in this kit. 6. Do not use hemolized blood specimen for testing. Wear protective clothing and disposable gloves while handling the kit reagents and clinical specimens. Wash hands thoroughly after performing the test. 7. Users of this test should follow the US CDC Universal Precautions for prevention of transmission of HIV, HBV and other blood-borne pathogens. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents are being handled. 9. Dispose of all specimens and materials used to perform the test as biohazardous waste. 10. Handle the Negative and Positive Control in the same manner as patient specimens. 11. The testing results should be read within 15 minutes after a specimen is applied to the sample well or sample pad of the device. Read result after 15 minutes may give erroneous results. 12. Do not perform the test in a room with strong air flow, ie. an electric fan or strong air-conditioning. Other Info STORAGE AND STABILITY Typhoid IgG/IgM test card should be stored at 4-40°C. The card may be stored at room temperature but not exceeding 40°C in the original sealed pouch. The shelf life or expiry of the card is printed on Pouch as well as carton label. The test kit should be kept away from direct sunlight, moisture and heat.

Send Message
product image
Biochemistry Analyzer

Yumizen CA40 Semi-automated Clinical Chemistry Analyzer: Yumizen CA40 is a semi-automated Clinical Chemistry analyzer with facility to perform Chemistry, Immunoturbidimetry and Coagulation Tests (PT & APTT). It is an ideal solution for small laboratories with the facility to perform a wide range of biochemical tests. Specification:- Semi-automated Clinical Chemistry analyzer with coagulation tests capacity (PT & APTT) 8 incubation positions for chemistry tests and 5 positions for coagulation tests 8-inch colored touch screen display Tri-level Quality Control with Levey-Jennings chart 6 filters with additional 2 open positions Show less

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Vitamin D Rapid Quantitative Test along with Finecare™ FIA Meter is a fluorescence immunoassay quantitative determination of total 25(OH) D2/D3 level in human serum or plasma. Results are to be used in conjunction with other clinical and laboratory data to assist the clinician in the assessment of vitamin D sufficiency. STORAGE AND STABILITY 1. Store at 4°C~30°C up to the expiration date. 2. The solid marker bottle can be stored at 2°C~8°C for 28 days after being reconstituted. 3. Do not remove the device from the pouch until ready to use. The Test Cartridges should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

Cortisol Rapid Quantitative Test The Finecare™ Cortisol Rapid Quantitative Test is a fluorescence immunoassay for quantitative determination of Cortisol in human serum, plasma or whole blood. The test is used as an aid to the screening of adrenal dysfunction and assessment of the treatment effect. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the test cartridge from the pouch until use. The test cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Ferritin Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of Ferritin in human whole blood, serum or plasma. The test is used as an aid to the assessment of iron deficiency anemia. STORAGE AND STABILITY 1. Store the test kit at 4 ~30℃ up to the expiration date printed on the package. 2. Do not remove the Test Cartridge from the pouch until ready to use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for
u s cdc?