Jaipur
+918529833535

'two aa alkaline batteries'

Items tagged with 'two aa alkaline batteries'

product image
Urinalysis Analyzer

Palm-sized, fitting easily into a doctor's bag or uniform pocket. The printer can be separated from the "PocketChem" analyzer, leaving it with a weight of just 180g. Corrective features for obtaining accurate test results Accurate readings can be obtained by eliminating the effects of chromaturia using the color correction test pad, by compensating measurements for the temperature of the surrounding environment using a built-in temperature sensor and by correcting specific gravity based on pH readings. Palm-sized analyzer driven by two batteries The analyzer is detachable from the printer. The analyzer is really portable and mobile. Simple operation. Just press the start button Measurement is performed by simply pressing the start button and placing a test strip. Test results can be simultaneously viewed on the display and printed out from the printer. Reliable test results with Creatinine correction Even with the use of spot urine, test results are reliable and are not affected by urine dilutions or concentrations. The P/C ration or A/C ratio is effective for the screening of renal diseases. Sample Urine Test strips AUTION Sticks/ Uriflet S (9UB)* / AUTION SCREEN * Except devices with 10V specifications Measurement items GLU (glucose), PRO (protein), BIL (bilirubin), URO (urobilinogen), S.G. (specific gravity), BLD (blood), PH (pH), KET (ketones), NIT (nitrite), LEU (leukocytes), CRE (creatinine) and ALB (albumin). Measurement principle Test strip: Dual wavelength reflectance method. (one wavelength for BLD measurement) Measurement wavelengths 3 wavelengths LED (565, 635, 760 nm) Sample supply method Manual dipping Measurement capacity 50 tests per hour Test strip reaction time About 60 seconds per test Measurement types Normal measurement and check measurement Display Custom LCD that displays information including type of test strip, measurement number (up to 4 digits), patient ID (up to 13 digits) and test results. Operator panel Panel sheet that provides 14 buttons including numeric buttons and start button. Memory capacity Test results for 100 samples External output Compliant with RS-232 C Measurement environment Temperature: 10 to 30 °C; Humidity: 30 to 60 % R.H. (non-condensing) *Temperature correction function used Dimensions 124 (W) x 81 (D) x 36 (H) mm Weight 180 g (without batteries) Power supply Instrument only: Two AA alkaline batteries or AC adapter Instrument with printer: AC adapter 7.5 V 3 A Power consumption 3 W Printer specifications Printer Thermal recording printer Printer paper High color development thermal paper (W 58 mm x φ26 mm) Dimensions 125 (W) x 133 (D) x 36 (H) mm Weight 180 g (without printer paper) Power supply AC adapter 7.5 V 3 A Power consumption 20 W

Send Message
product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 300 Diagnostic Reagent from Accurex (Pack Size : 30 x 10 ml). Alkaline Phosphatase reagent is used for determination of Alkaline Phosphate activity based on kinetic method using p-nitrophenyl phosphate (p-NPP). Alkaline Phosphatase is a single reagent system using one step procedure & Alkaline Phosphatase activity can be determined in just 2.5 minutes & is is a Highly stable reagent. Alkaline Phosphatase cleaves p-nitrophenyl phosphate p- NPP in the presence of magnesium ions to form p nitrophenol & phosphate. About Method – p-NPP-DEA Buffer – Kinetic reaction with 60 seconds lag phase – Easy reconstitution : Tablet + Diluent – High liquid stability : 21 days Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphate activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Principle Alkaline Phosphatase cleaves p-nitrophenyl phosphate p- NPP) in the presence of magnesium ions to form p nitrophenol and phosphate. The intensity of the yellow color formed is directly proportional to the Application alkaline phosphatase activity in the specimen and measured kinetically. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details Two liquid reagent systems. Stable till the expiry date indicated on the label when stored in 2-8°C.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ SAA Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of serum amyloid A (SAA) in human whole blood, serum or plasma. This test is used as an aid to assist in the diagnosis of infection and inflammation. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Medical Equipment

With state-of-the-art screen technology, BeneVision N Series patient monitors deliver clear, multi-color, wide-format displays for users to capture and review information at a glance. With multi-touch operation, users can control the monitor and review patient data quickly and easily. BeneVision N Series provides the world's best monitoring technologies for you, with new applications being developed. Perfect hemodynamic monitoring solution, not only provides a variety of measurement methods, ICG, PiCCO, ScvO2, C.O., but also provides comprehensive analysis tool – HemoSight™. HemoSight™ focuses on hemodynamic treatment process, and provides appropriate tools for each stage. Advanced modular regional tissue oxygenation measurement -- INVOS rSO2. Volumetric capnography & metabolic measurement help to evaluate the adequacy of ventilation and determine the ventilator setting effectively, and improve the safety of weaning and extubation. Powerful Clinical Assistive Applications (CAAs) to support efficient decision making when time is critical. Each CAA focuses on major clinical workflow challenges that individual departments face. Solutions optimized for each point of care At every point of care, such as ICU, CCU, NICU, OR, PACU, ER, BeneVision N Series patient monitors always provide a suitable solution to meet your clinical needs for monitoring your patient's status anywhere, anytime, even on your way through mobile devices. With excellent transport solution, BeneVision N Series patient monitor brings a smooth workflow and safe data management through the entire care process. BeneVision takes less time to operate, and helps you understand the patient's variables quickly. With HL7,BeneVision N Series patient monitors can directly connect to the hospital clinical network.BeneVision N12 is capable of monitoring multiple parameters simultaneously both at bedside and during transport. IT structure designed for seamless connectivity Mindray patient monitoring system incorporates extensive network adaptability to integrate with the hospital's current network infrastructure, ensuring that critical data is on hand for clinical decision making - and is integrated with the patient record. Mindray's central station and eGateway further enhances the connectivity of BeneVision to your clinical world. Bedside devices data and other clinical systems data are shared to support your diagnosis and clinical decisions.

Send Message
product image
Laboratory Usage

Soil moisture meter TDR 150 Portable soil moisture meter allows you to obtain readings on the go at the press of a button. Variable rod length options provide soil moisture measurements at your ideal root zone. With new enhancements, the TDR 150 provides significant improvements in performance and measurement accuracy for optimal turf and soil environments. Increased accuracy of soil moisture (Volumetric Water Content) Measures EC (Electrical Conductivity) Measures Turf Surface Temperature Option to add on Bluetooth and GPS Data logger records approximately 50,000 measurements Industry exclusive backlit display Ergonomic handle Data collected with USB flash drive No PC interface needed Powered by AA lithium batteries Ideal for measuring containers on benches Optional IR Temp sensor to measure canopy TDR 150 SPECIFICATIONS Measurement Principle: Time - domain measurement methods Measurement Units: Percent Volumetric Water Content (VWC) Resolution: 0.1% VWC Accuracy: +- 3.0% VWC with Electrical Conductivity (EC) < 2 mS/cm Range: 0% to saturation (Saturation up to about 50% volumetric water depending on soil type) Battery/Life: 4 AA lithium batteries; approximately 100,000 readings without backlight Data Logger: 50,000 measurements EC Range: 0 to 5 mS/cm, Resolution: 0.01 mS/cm, Accuracy: +/- 0.1 mS/cm Temperature Range: -30°C to 60°C, Resolution: 0.1°, Accuracy: +/- 1°C

Send Message
product image
Laboratory Usage

TACHOMETER/STROBOSCOPE, Model : BP-2259 ( 2 in 1, DIGITAL PHOTO TACHOMETER with DIGITAL STROBOSCOPE ) FEATURES* Intelligent, microprocessor circuit design, high accuracy, wide range, digital readout.* One instrument include two functions of " Digital Photo Tachometer " & " Digital Stroboscope "* Digital Stroboscope :Wide setting range from 100 RPM to 100,000 RPM, digital display with high accuracy. Modern solid state high visible orange light, long life, almost maintenance free. It is ideal for inspectingand measuring the speed of moving gears, fans, centrifuges, pumps, motors and other equipment used in general industrial maintenance, production, quality control, laboratories and as well as for schools and colleges for demonstrating strobe action.* Digital Photo Tachometer :No contact RPM measurement, wide measuring range from 0.5 to 100,000 RPM. 0.1 RPM resolution for the measured value < 1000 RPM. The last value, max., value, min. value can be stored into the memory automatically & be obtained by pressing " Memory Call Button ". High visible LCD display gives RPM reading exactly with no guessing or errors.* The use of durable, long lasting components, including a strong, light weight ABS plastic housing.Cabinet has been carefully shaped to fit comfortable in either hand. GENERAL SPECIFICATIONS Display 5 digits, 10 mm ( 0.4" ) LCD Operation 0 - 50 (32 - 122 ). ( Liquid Crystal display ) with Temperature function annunciation. Operating Less than 80% RH.Accuracy ± ( 0.1 % + 2 digit ). Humidity Sampling Time 1 second ( 60 RPM ). Size 215 x 65 x 38 mm.Time base:Quartz crystal. (8.5 x 2.6 x 1.5 inch). Circuit Exclusive one-chip design Weight 300g(0.66 LB)/including battery.microprocessor LSI circuit. Accessories : Carrying case ................... 1 PC.Battery 4 x 1.5V AA ( UM-3 ) battery. Operation manual ..............1 PC.ELECTRICAL SPECIFICATIONS ( PHOTO TACHOMETER )Measurement Range 5 to 99,999 RPM Resolution 0.1 RPM ( < 1,000 RPM ) 1 RPM ( 1,000 RPM )Photo Tach. detecting distance 50 to 150 mm/2 to 6 inch. * Typical max. 300 mm/12 inch depending upon ambient light.ELECTRICAL SPECIFICATIONS ( STROBOSCOPE )Stroboscopic 100 to 100,000 FPM/RPM Flash tube High efficiency orange LED Flash Rate FPM: flash per minute lamp.RPM : round per minute Flash Duration Approximately 60 to 1,000Flash Adjust 3 ranges : microseconds. Range Range A: 100-1,000 FPM Flash color Orange Range B: 1,000-10,000 FPM Flash Duration Approx. 16% of period time. Range C: 10,000-100,000 FPM Flash Adjust Coarse adjust knob and Resolution 0.1 FPM/RPM. Knob Fine adjust knob.(Less than 1,000 FPM/RPM) Calibration Crystal time base and1 FPM/RPM microprocessor circuit, don't(Over 1,000 FPM/RPM) necessary take any external calibration process. OPERATIONS PROCEDURES ( STROBOSCOPE )Preparation Determine the range switch to " 1000 RPM " ," 10,000 RPM " or" 100,000 RPM " position.Checking When checking speed, care must be taken to insure that the strobe is flashing in Speed unison (one to one) with the object being monitored. A Stroboscope will also stop motion at 2:1, 3:1, 4:1 et., this is normally referred to as harmonies. To be sure of unison, turn the dial until two images appear - this will double the actual speed. Then lower the flashing rate until a single and stationary image appears -this is the actual true speed.Checking For motion analysis, simply locate the actual speed as mentioned above and then Motion turn the dial slowly up or down. This will give a slow motion effect allowing complete inspection.

Send Message
product image
Hemoglobin Meter

Get the fastest hemoglobin and HCT test within 10 seconds, Buy Accurex URIT-12 Hemoglobin Meter Online. This Hemoglobin tester gives Accurate & Reliable Result. The Urit 12 hemoglobin machine is the best digital hemoglobin Meter with easy 3-step operation. The hb meter is is perfectly fit for the filtration of the numbers of blood donors, POCT, and hemoglobin testing in medical examination center. etc. It works on the prinicple of Optical reflectance. Sample: Capillary or venous whole blood (13~15 ul) & Strips: Accurex H12 Hemoglobin Test Strip URIT-12 is an easy-operation, fast-testing and portable hemoglobin testing Meter, which is perfectly fit for the filtration of the numbers of blood donors, POCT, and hemoglobin testing in medical examination center (MEC) etc. Compared to HiCN-HB method, the results are satisfactory. • Fast hemoglobin and HCT test within 10 seconds • Accurate & Reliable Result • Easy 3-step operation Parameter: Hemoglobin, HCT (Hematocrit) Principle: Optical reflectance Strip: H12 Hemoglobin Test Strip Speed: 10 seconds Sample: Capillary or venous whole blood (13~15 ul) Memory: 250 test results Measuring Range: 4.0g/dL 24.0g/dL(g/L optional) Quality Control: HQ-A Hemoglonbin control solution Calibration: Factory calibrated according to ICSH Power: DC 6V (Two CR2032 Batteries) Automatization: Self-checking, auto-judging and displaying malfunction Dimension: 102mm 50mm 19mm Accuracy: accuracy ≥ 96%,the correlation is very good in the comparison between URIT-12 and ICSH method. Precision: CV < 5%,testing samples including high, medium & low concentration, the CV of 10 repeated test results is 1.8% 2.2% 2.7% respectively. Hematology analyzer is not suitable for the fast and single hemoglobin testing out of the laboratory and the fast hemoglobin filtration for numbers of blood donors, therefore, it’s very necessary to find a kind of method for fast and accurate hemoglobin testing. When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors automatically measure the change of reflectance in membrane. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Other Info Hemoglobin testing is one of the important clinical hemanalysis items. It is useful for the diagnosis of all kinds of anemia. In clinical laboratory, many test items including hemoglobin can be gotten from hematology analyzer.

Send Message
product image
Glycohemoglobin Analysis

Accurex Xpress A1c Glycohemoglobin Analysis System Kit . The Kit contains HbA1c Meter, 1 Sampler, 1 box of 25 test strips, Buffer A, Buffer B. Glycohemoglobin Analyzer It is used for testing glycohemoglobin concentration as an aid to monitor the risk of developing diabetes & control the status of diabetes. Buy Xpress A1c Meter Kit Online from Accurex Point of Care (POC ) Range – The HbA1c analyzer is specifically designed to be used with the corresponding test strip. HbA1c analyzer Hemoglobin A1C is a common blood test that measures blood glucose levels over the past two to three months. •Glycohemoglobin Analyzer •Handheld HbA1c Meter •Battery Operated •No Pipetting, No Lysing •Lab like Accuracy •Battery Operated •Truly Portable •Voice prompt for •User Guidance • Accurate result with cv <3% •Lab like accuracy with 95% •No interference of HB Variant •No pipetting •No lysing •Reagent: Suitable to store at room temperature (upto 30º C) The Power of HbA1c in your Hand esting Principle: Boronate Affinity Chromatography Testing Parameter: Glycohemoglobin (HbA1c) Measuring Range: 4.0% – 14.0% Precision: CV <3% (HbA1c: 4.0% – 6.5%) Blood Sample: Finger Prick or Venous Blood ( EDTA Anticoagulant) Blood Volume: About 3ul Testing Time: About 5 minutes Data Unit: Set in Advance the Data Unit • NGSP%; IFCC mmol/mol; eAG* mmol/l Voice Prompt: Voice Prompt to Guide the user Data Storage: 1000 Testing Data Data Port: Mini USB data interface can be connected with HIS/LIS; System Thermal Printer Power Required: AAA Battery x 4 Analyzer Dimension: 61.6 x 122.9 x 24.5 mm Screen Size: 47 x 32 mm” Safety Information LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Other Info Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message
product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 60 Diagnostic Reagent (Pack Size : 12 x 5 ml) from Accurex. Alkaline Phosphatase 60 are used in the diagnosis of hepatobiliary disorders and bone disease associated with increased osteoblastic activity. Alkaline Phosphatase high levels may be a sign of a liver problem or a bone disorder Alkaline Phosphatase 60 reagent is set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP), the reagent is a Highly stable reagent & its activity can be determined in just 2.5 minutes. About Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Pack Size : 12 x 5 ml Principle The working solution is stablə for 21 days at 2- 8°C. The working solution should be prepared and stored in the dark (working solution bottle) provided.This is critical because the reagent is light sensitive. It should therefore be kept away from direct light. Alkaline Phosphatase cleaves p-nitrophenyl phosphate (p-NPP) into p-nitrophenol and phosphate. p-nitrophenol is a yellow color compound in alkaline medium and absorbs light at 405 nm. The rate of increase in absorbance at 405 nm. is proportional to Alkaline phosphatase activity in specimen. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label. The working solutions of Non Prostatic Acid Phosphatase & Total Acid Phosphatases are stable for 7 days at 2-8°C.

Send Message

Still searching for
two aa alkaline batteries?