Jaipur
+918529833535

'tray'

Items tagged with 'tray'

product image
Fluorescence Immunoassay Analyzer

The FineCare FIA Meter II plus SE is a top-class fluorescence immunoassay analyzer with a built-in thermal printer, Wifi, internet connectivity, large LCD display for testing common clinical diseases. Description The FineCare FIA Meter II plus is a top-class fluorescence immunoassay analyzer with a built-in thermal printer, Wifi, and internet connectivity, large LCD display for testing common clinical diseases. Technical Specifications Analyses common clinical diseases such as Diabetic & Renal injury Markers, Thyroid function, Fertility, Cardiac Markers, Inflammation Markers, Tumour Markers Built-in Thermal Printer Real-time auto printing Support for external printer Dimension :- 239mm x 278mm x 148mm Weight : 3.3kg Large Display 8” LCD Capacitive touch screen Intuitive user interface Specially designed sampler for a small volume of the specimen. Test Reagent Suitable for whole blood, serum, plasma, and urine Room temperature storage Get results in 3 -15 minutes Test Device Tray Multiple testing modes available Unique quick mode for a large number of samples Keywords large number fluorescence small volume Cardiac Markers Thyroid function large LCD display Inflammation Markers Renal injury Markers internet connectivity common clinical diseases LCD Capacitive touch screen Intuitive user Built-in Thermal Printer Immunoassay Analyzer, Finecare Analyzer, TSH, HbA1c, Point of care , immunoassay, Clia Analyses common clinical diseases such as Diabetic & Renal injury Markers, Thyroid function, Fertility, Cardiac Markers, Inflammation Markers, Tumour Markers

Send Message
product image
Laboratory Usage

Product Details: Packaging Type Box Usage/Application Industrial Color Semi-transparent Make Parafilm Thickness 0.127mm Stretching 200 % According to the increasing demands of the customers, we are involved in offering best quality of Parafilm M. this Parafilm M is known for its unmatchable quality and reasonable rates. The offered Parafilm M is available in the market in wide range and extensively used as a tray and shelf liner to prevent slippage and breakage of bottles, containers, and instruments. Features: Superior quality Reasonable prices Smoothly finished

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 190-1100 nm Optical System Double Beam Spectral Bandwidth 1 nm Wavelength Accuracy 0.1 nm Wavelength Repeatability 0.1 nm Photometric Accuracy 0.3 % T Photometric Range 0-200 % T, -0.3 - 3.0 A, 0-9999 C Photometric Repeatability 0.2 % T Stray Light Less than equal to 0.05%T Stability 0.001 A/h Detector Silicon Photodiode Lamp Type Deuterium Lamp, Tungsten Halogen Lamp Baseline Flatness 0.001 A Noise 0.001 A Data Output Port USB Port Display Graphic LCD (320*240 Dots) Dimensions 630 x 430 x 206 mm Printer Port Parallel Port Weight 26 kg We are the leading manufacturer of a wide range o These products are UV-VIS Spectrophotometer easy to operate and highly appreciated for its durability. Specifications: Wavelength Range 190-1100 nm Mode Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics Scanning Speed Fast / Medium / Slow Wavelength Accuracy 0.1 nm Bandwidth 1 nm Wavelength Reproducibility 0.1 nm Photometric Display Range 0-200 % T, -0.3 - 3.0 A, 0-9999 C Photometric Accuracy 0.3 % T Photometric Repeatability 0.2 % T Stability 0.001A/h @ 500 nm Baseline Flatness 0.001 A Noise 0.001A Stray Light < 0.05% T @ 220nm, 360 nm) Data Output Port USB Printer Port Parallel Port Display Graphic LCD (320*240 Dots) Lamps Deuterium Lamp & Tungsten Halogen Lamp Detector Silicon Photodiode Dimensions(L*W*H) 630 x 430 x 206 mm Net Weight 26 Kg

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range* <0.5%T over entire wavelength range* ,

Send Message
product image
Digital Spectrophotometer

Detector Silicon Photodiode Path Length 10 mm Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Specifications: Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Output % T: 0 to 100%, Abs:0 to 1.999 Conc: 0 to 1999 Detector Silicon Photodiode Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Path length 10 mm Spectral Bandwidth 10 nm Wavelength Resolution 1 nm on Display 2% digit LED Wavelength Accuracy 1 nm Repeatability ±1 nm Read out 3½ digit LED, 1 nm step Operating Temp 5 to 45°C Path length 10 & 50 mm in Model LT-38 Additional Information: Item Code: UV-Mini-1240 Yes! I am interested Spectrophotometer REQUEST CALLBACK Spectrophotometer Ask for Price Product Price :Get Latest Price Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range*

Send Message
product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Urinalysis Analyzer

The Orinalyser U500 Urine Analyser is a Multi Strip Urine Reagent Strip Analyser. It is a reflectance photometer that analyzes the intensity and color of light reflected from the reagent areas of a urinalysis reagent strip. The analyser throughput is 500 tests per hour and the measuring cycle is 7 seconds per test. •500 tests/hour throughput •Large LCD touch screen offers simple menu navigation •Auto strip detection and alignment for better efficiency •Uniquely designed strip platform and waste tray unit for easy one-step cleaning •Autocalibration and waste disposal. •Auto flag for abnormal results •RS232C & USB port for data transfer

Send Message
product image
Clinical Chemistry

The Autochem Xact Pro is a Fully Automatic Random Access Clinical Chemistry Analyzer. It is a compact, benchtop analyser with throughput up to 200 tests per hour. First-in-Class On-board Warm-water Laundry System Probe with Collision-Protection System Multi function Probe which works as mixer also Probe with Capacitance based liquid level sensor Robust Multi-functional Software Intelligent" Mixing Arm Removable & flexible Sample - Reagent Disc with 40 Open position for reagent & samples respectively. DESIGNED FOR UNINTERRUPTED WORK FLOW OTHER FEATURES ROBUST MULTI-FUNCTIONAL SOFTWARE Probe with Collision-Protection System Both horizontal and vertical collision protection ensures that system re-starts testing after any unwanted physical intervention. This prevents wastage of reagents, saves test time and increases life of probe Multi functional Probe Probe has flexibility to work even as a mixer in case in-built mixer does not work Probe with Capacitance based liquid level sensor Probe with liquid level sensor checks and indicates the presence of adequate sample or reagent in the container before starting testing process. Thus prevents unwanted interruptions in testing process “Intelligent” Mixing Arm User defined, variable three level mixing speed ensure thorough mixing Accurate performance of regular and immunoturbidimetric assays Independent cleaning station for mixer which prevents carry-over ensuring high precision Removable & flexible Sample – Reagent Disc 40 Open position for reagent & samples respectively Facility to use primary & variable sample cup as well as non fixed position for Sample, Control, Calibrator & STAT samples Two bottle sizes of 18 mL or 5 mL with unique design to reduce reagent dead volume Optional internal Reagent & Sample barcode reader makes the operation user friendly & ensure correct result reporting Reaction tray 60 reusable plastic reaction cuvettes which is also scanned before performing the test which means less recurring cost without compromising on quality. To assure precise results Individual replacement of cuvette offer lower consumable cost REFLEX Testing Functionality Allows user to program Low & High panic value for a particular test which triggers auto-testing of assigned tests which ensures faster and comprehensive reporting Dynamic & Real-time display of Test Running Status for quicker decision making Running status of reagent tray, Sample tray & reaction tray Real-time monitoring of Reaction curve On board inventory management Real-time monitoring of reagent residual volume saves reagent cost & time In-built full QC Program Provision to run 3 levels of control with Levey Jennings graph which gives confidence in reporting with multiple rules (1SD, 2SD and 3SD) Reagent, Calibrator & Control lot monitoring User friendly Bi-Directional LIS Interface

Send Message
product image
Clinical Chemistry

TURBOCHEM MAGNA Constant throughput of 300 Tests/hour Discrete random access Bench Top Biochemistry analyzer Independent Probe for Reagents and Sample. Dedicated mixer which enhances faster mixing of reagents and sample High precision results with Low CV% Probe crash prevention with high sensitive liquid level detection of sample/reagents On board laundry with 5 stages of washing Intelligent QC management Bidirectional LIS connectivity Minimal consumable cost for instrument maintenance Remote maintenance, interactive trouble shooting with online application support Constant Throughput of 300 Test/Hour: Guarantees output in any combination Reagent and Sample Tray: Loading more reagent and sample at same time. Intelligent QC Management: Enable QC rules that suit you. Bi-Directional LIS Connectivity: Ensures superior lab process. Specially Designed Mixer: Ensure Homogeneous mixing of reagent and sample.