Hemostasis Analyzer
Product Description:
It’s an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer.
Product Features:
Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S performed using Light scatter principle.
Protein C, Antithrombin III done by Chromogenic Principle
Tests like D Dimer performed using Immuno-turbidimetry principle
Interactive touch screen interface
Clotting Graph provides details of the clotting test
Cuvette and reagent management software
Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors
Temperature stability at 37 degree C to perform the tests
Low Reagent Consumption
USB Connectivity
CE mark
Product Applications:
ECL 412 has uses in various routine IVD labs for doing routine PT and aPTT
It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII
It is used as Standby to bigger systems, in accredited centers
It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc
General Specifications:
4 channel semi-automated hemostasis instrument
It can perform 4 simultaneous tests of the same parameter
Sample id can be 14 digits alphanumeric, with progressive id or custom id options
It is also possible to have a second row of assay preparation/incubation during the analysis of the current line, using preparation line option
It can run assays in single or duplicate (programmable per assay)
Optically detects and automatically moves to the next assay steps and auto starts the measurements
Tests principles:
Clotting (scattered light at 640nm)
Chromogenic (colorimetry at 405nm)
Immuno-turbidimetric (turbidimetry at 800nm)
Dimensions / Weight:
Dimension : 300 x 290 x 90 mm
Weight : 3 kgs
Environmental requirements:
Operating Temperature : 17-32°C
Humidity: Max. 80% Relative Humidity, non-condensing
Power:
Power Supply: 100-240 VAC and 50/60 Hz
Power Consumption: 45 Watts
In-Rush Power: 150VA or less
Calibrations:
Up to 6 calibration levels per assay
Storage of the active calibration curve
Quality Controls:
Up to 12 different control names total can be assigned to any given assay
Automatic Levey-Jennings plotting
Automatic statistics calculation
Storage of Quality Control results
Stored results:
Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations
Up to 600 results for QC determinations (run in duplicate)
Up to 900 results for patients (run in duplicate)
New results automatically replace the oldest results of the appropriate category past the maximum storage allowance
Reaction curves are exclusively stored on the external USB pendrive.
Regular backup and file purging is recommended from the USB pendrive to insure rapid operations. (We recommend at least a monthly purge from a computer to back up and remove CH files)
USB pendrive , FAT32 formatted
Send Message