Jaipur
+918529833535

'to 300 samples'

Items tagged with 'to 300 samples'

product image
Instruments

SV300 Pro is dedicated to simplifying the use of ventilator. With the design in line with clinical needs, SV300 Pro is able to improve the efficiency of clinical operations and maintenances. Frameless Capacitive Screen Frameless designed capacitive screen, more precise touch and easier to clean and disinfect. Comprehensive Comprehensive With comprehensive ventilation modes and decision-supporting tools like SBT, the SV300 Pro manages to fit for the most stringent ICU environment. Intelligent Ventilation Adaptive minute ventilation(AMV TM ) together with IntelliCycle TM enables the ventilator to automatically adjust ventilator settings to reduce the need of frequent ventilator settings adjustment and improve the patient-ventilator synchrony. p69-s3-1 CPRV Ventilation CPRV TM is specially developed for CPR procedure. Quickly access the mode with one-click start, allowing precision ventilation and CO2 monitoring. When used with Mindray unique Electronic Impendence Threshold Device(e-ITD TM ) technology, it can further improve the efficacy of CPR with increase venous return and perfusion. p69-s3-2 Adaptive With a weight no more than 10kg, equipped with powerful turbine and integrated CO₂/SpO₂ monitoring, the SV300 Pro is appropriate for all levels of patient acuity and in all care settings, from the patient's bedside to another point of care with its intra-hospital transport friendly designs.

Send Message
product image
Instruments

The SV300 is a state-of-the-art ventilator that's simple to configure, easy to operate, and versatile in use. It treats pediatric and adult patients with all acuity levels at ICUs and Intermediate Care. Adaptive With its comprehensive list of standard features, including the latest modes of ventilation, the SV300 is appropriate for all levels of patient acuity and in all care settings, from the patient's bedside to transport to another point of care. Comprehensive Equipped with functions that are usually found on intensive care ventilators, the SV300 comes with extensive ventilation modes and unique features that make it a top level ventilator. p84-s4-1 Volumetric CO₂ measurement p84-s4-2 Weaning indicators p84-s4-3 O₂ Therapy p84-s4-4 Intelli Cycle Thanks to the intuitive UI design of the SV300, each function is in logical order so that clinicians do not need to navigate a complex menu. In addition, both the valves and flow sensor support autoclaving. This safety concept is designed to meet the current clinical trends of protecting patients even under the most demanding conditions.

Send Message
product image
Laboratory Usage

Aided by a team of qualified and expert designers, we are involved in offering a wide gamut of Refractometer Manual. The offered product is appreciated among customers owing to its fine finish & optimum quality. This product is manufactured by our workforce utilizing excellent quality material and sophisticated techniques in accordance with the set quality standards. Our given product is accessible in assorted specifications as per the definite requirements of the customers. Features: Precisely designed Accurate testing Reliability ABBE Refractometers: Model NAR-1T LIQUID Range 1.3000 to 1.7000 with sugar scale 0-95% built in light fourth place by estimation 5 to 50ºC temperature Model NAR-2T for high temperature samples from 0 to 120ºC temperature Model NAR-3T for precision measurement of the fourth place 5-50ºC temperature Model NAR-4T for high refractive index measurement range 1.4700 to 1.8700 Abbe Refractometer Manual Model 2WAJ - R I- nD 1.3000 to 1.7000 & Sugar percentage (Brix) Product Details: Model 2WAJ-RI Application Industrial, Laboratory Display Digital Operation Manual Range 0-95%

Send Message
product image
Digital Spectrophotometer

Product Details: Brand Swastik Weight 3.5 Kg Material PVC Color White Display LED Display Type Digital Brix Range 0 to 95 % With the aid of our procuring agents, we are offering our clients a sustainable range of Abbe Refractometer Manual. The product we are offering determines Refractive Index & Dispersion Properties of Solids & Liquids. Details: R.I.Scale: 1.3000 1.7100 Accuracy: 0.001 or 0.0005 (direct Reading) Sugar Scale: 0.95% Accuracy:0.5%(Direct Reading). Features: Single Eye Piece for Reading Scale & Viewing the Demarcation Shadow Horizontal Prism for Easy application of Test Samples Water Jacketed Prism Box Established in the year 2015, appreciated for Manufacturer, Supplier, Trader and Service Provider a premium quality of Scientific Instruments, "Swastik Scientific Instruments Private Limited", Company has Experience of more than 3 decades. The product range provided by us is inclusive of Spectrophotometers, P H Meter Digital and Melting Point Apparatus Automatic. Our offered product ranges are made by the well qualified professionals by utilizing optimum quality basic inputs as per the set industry norms. We procure these products from the trustworthy vendors of the market; these vendors are widely popular for their qualitative product range. Apart from this, we are delivering the offered products safely within the requested period of time with the help of highly efficient distribution network. We are backed by a huge base of certified vendors of this domain. With the help of these vendors, we are able to cater the bulk requirement of the offered products. Our vendors are well versed with our quality centric approach and customer preferences; hence they are manufacturing the offered products accordingly. Our vendors are manufacturing all the offered products as per the industry defined norms and standards. To cater the client’s requirements, we are offering our products in different stipulations.

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180T is a fully automated Glycohemoglobin analyzer based on HPLC (High Performance Liquid Chromatography) and is highly effective for ß-thalassemia testing. Measurement speed: 3.5 minutes/test Measurement Item as below HbA2 HbF HbA1c (Stable HbA1c, S-A1c), HbS, HbC, HbE and HbD can be detected. Column design with no more pre-filter change. Color LCD with reagent level, graphs on screen. Samples Whole blood or hemolysis sample Measurement items HbA1c(Stable HbA1c, S-A1c), HbA2 and HbF (HbS, HbC, HbE and HbD can be detected.) Reagents *1 ELUENT 80A, ELUENT 80B, ELUENT 80CT and HEMOLYSIS WASHING SOLUTION 80H Column *2 COLUMN UNIT 80T Measurement principle Reversed-phase cation exchange chromatography Detection method Dual-wavelength colorimetry (wavelengths measured: 420nm/500nm) Resolution 0.1% Ratio, 1 mmol/mol Measurement range *3 HbA1c : 3-20%, 9-195 mmol/mol HbA2 : 2-10% HbF : 0-100% Guaranteed measurement range *4 HbA1c : 4.2-12.9%, 22-117 mmol/mol HbA2 : 2.4-6.3% HbF : 0.1-14.3% Processing speed 210 seconds per sample Sample consumption Approx.14μL(whole blood) Sample container Blood collection tube (12.3 to 15mm diameter) × ( 75 to 100mm length) Sample cup(500μL) Sampling method Cap-Piercing Rack type ARKRAY racks Number of measurement samples One-way transportation (factory set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approx. 39℃ Display Color graphic LCD with backlight Memory capacity 500 test results ( including calibration results ) Built-in Printer Termal printer, 58mm thermal paper External output Serial 1 port (Can be optionally used as an Ethernet port.) Measurement conditions Temperature : 15-30℃ Humidity : 20-80% relative humidity (non-condensing ) Required sample volume Blood collection tube : Minimum 10mm away from the bottom Sample cup : 400μL or more Warm-up time Maximum 30 min. Dimensions 530(W)×530(D)×530(H)mm (Not including the hemolysis washing solution bottle) Weight Analyzer: Approx. 39kg, Sampler: Approx. 4kg Power supply AC100V-240V ±10% 50/60Hz Power consumption Max. 300 VA *1, *2 Reagents and column are sold separately from HA-8180T analyzer. *3 Error-free measurement ranges. *4 Guaranteed ranges for obtaining results equivalent to those from HA-8160 TP mode measurement. ※Design and specications may be changed without prior notice

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message
product image
Hematology

Buy the Best 5 Parts Hematology Analyzer – ACCULAB CBC 560+. This Hematology Analyser Machine is an advanced and automatic hematology analyzer, comprising 5 parts, 29 parameters, and 3 histograms assay, offers throughput of 60 tests/hour. Features: Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting and Cyanide-free method for HGB test along with 3D holographic scattergram to display the accurate 5 part differentiation of WBC. Equipped with a 14 inch touch screen and large storage capacity for 100,000 results, this hematology analyzer has interface of 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader. With CBC mode, CBC+DIFF mode, Venous whole blood, Capillary whole blood and Prediluted test mode, this hematology analyzer is an ideal unit for white blood cell counts, complete blood Measuring principle Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test Sample volumes CBC+DIFF mode: ≤ 20 μl CBC mode: ≤ 10 μl Throughput 60 tests/hour Assay Items 29 parameters, 3 histograms Display 14 inch touch screen Storage 100,000 sample results, including histograms, scattergrams and patient information Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT,PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%,BAS%,NEU#, LYM#, MON#, EOS#, BAS# 4 Research parameter: ALY%, ALY#, LIC%, LIC# Performance Item Linearity range Carry Over CV WBC 0-300 × 109/L ≤ 0.5% ≤ 2.0 % RBC 0-8.00 ×1012/L ≤ 0.5% ≤ 1.5 % HGB 0-250 g/L ≤ 0.5% ≤ 1.5 % PLT 0-3000 × 109/L ≤ 1.0% ≤ 4.0 % Interface 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader Power Consumption 400 VA Power Supply AC 220V±10%, 50/60Hz, 110V±10%, 60Hz Packaging dimension (W×D×H) 670 × 590 × 790 mm Gross Weight 53 kg Safety Information All the samples, controls, calibrators, reagents, waste and areas contacted with them are potentially biohazardous. Wear proper personal protective equipment (e.g. gloves, lab coat, etc.) and follow safe laboratory procedures when handling them in the laboratory.

Send Message
product image
Clinical Chemistry

utozyme Albumin 300 Diagnostic Reagent from Accurex. Albumin 300 is used for determination of albumin in serum or plasma based on BCG method. Autozyme Albumin is a single reagent system which is ready to use, Albumin is linear up to 6 gm% & can be determined in 1 minute at room temperature. Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex. Albumin normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). About Autozyme Albumin is a reagent set for determination of albumin in serum or plasma based on BCG method Autozyme Albumin is a single reagent system, ready to use. Autozyme Albumin is linear up to 6 gm% Albumin can be determined in 1 minute at room temperature The shelf-life of Autozyme Albumin is 18 months Pack Size : 2 x 50 ml Principle Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex, The absorbance of this complex is proportional to the albumin concentration in serum or plasma. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and an abnormal commercial reference control serum,. it should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, cleanliness of glassware and accuracy of pipetting. Other Details The reagents are for in vitro diagnostic use. BCG reagent and standard should be stored at temperature indicated on the bottle label.

Send Message

Still searching for
to 300 samples?