Jaipur
+918529833535

'test 20 items'

Items tagged with 'test 20 items'

product image
immunoassayReagents

INTENDED USE The Finecare™ 2019-nCoV RBD Antibody Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for qualitative and semi-quantitative detection of spike receptor-binding domain (RBD) antibodies of novel coronaviruses (2019-nCoV) in human fingerstick whole blood, venipuncture whole blood, serum or plasma specimen. The 2019-nCoV RBD antibodies are protective antibody produced by the human body after inoculation with 2019-nCoV vaccine or infection with 2019-nCoV. The test is intended as an aid to assess the adaptive humoral immune response to the 2019-nCoV RBD protein. STORAGE AND STABILITY 1. Store at 4~30°C in the sealed pouch up to the expiration date printed on the package. Do not freeze. 2. The test device should be used within 1 hour after taking out from the foil envelope. 3. Keep away from sunlight, moisture and heat. 4. Kit contents are stable until the expiration date printed on the outer box.

Send Message
product image
Immunoassay Reagents

INTENDED USE The Finecare™ 2019-nCoV lgM/lgG Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for qualitative detection of IgG and IgM antibodies of novel coronaviruses (2019-nCoV) in human whole blood, serum and plasma specimen. Clinically, the test is to be used as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by 2019-nCoV. The test provides preliminary test results. Negative results cannot exclude the possibility of 2019-nCoV infection and they cannot be used as the sole basis for treatment or other management decision. STORAGE AND STABILITY 1. Store at 4-30°C in the sealed pouch up to the expiration date printed on the package. Do not freeze. 2. The test device should be used within 1 hour after taking out from the foil envelope. 3. Keep away from sunlight, moisture and heat. 4. Kit contents are stable until the expiration date printed on the outer box.

Send Message
product image
Clinical Chemistry

The SAL 6000 modular system delivers fast throughput and powerful integration across immunoassay and chemistry systems. Broad assays can be tested with one sample tube, which can maximize operation efficiency and increase lab productivity. Product Description SAL 6000 Modular System delivers fast throughput and seamless integration of CL-2000i Chemiluminescence Immunoassay System and BS-800 Modular System. In conjunction with the SPL 1000 Sample Processing System, this scalable platform not only provides optimized workflow, it also offers satisfactory operator experience. Features · Seamless integration, workflow optimization · Uniform software interface, easy of operation · One tube sampling, flexible to test · Technology and quality heritage · Flexible scalability, on-site upgrading · Comprehensive test menu Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 6000 Assays Clinical Chemistry Power Supply 220 V Usage/Application Hospital Frequency 50 Hz

Send Message
product image
Rapid Test

The OnSite HSV-1 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) in human serum, plasma or whole blood. Type-specific detection by utilizing glycoprotein G1. Single test that detects and differentiates IgG and IgM anti-HSV-1. High confidence as test is in agreement with market leading ELISA test: 90.7% IgG; 85.0% IgM. Flexible specimen types including serum, plasma, or whole blood which allows testing at any time without special specimen preparation. Small sample volume (10 µL) enables multiple testing on the same specimen without having to re-draw the patient. Initial treatment action can begin during the patient’s visit as test results are available in 10 minutes. Easily transported, and can be stored for 24 months, 2-30oC. Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance HSV-1 & HSV-2 Flyer Insert U.S. CDC HSV Homepage: Genital Herpes Fact Sheets WHO: Herpes Simplex Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message
product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message
product image
Rapid Test

The OnSite Malaria Pf/Pv Ab Combo Rapid Test is a lateral flow chromatographic immunoassay for the simultaneous detection and differentiation of antibodies including IgG, IgM and IgA to Plasmodium falciparum (Pf) and Plasmodium vivax (Pv) in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimens Utilizes highly purified antigen to ensure test sensitivity and specificity Detects total antibodies to Pf and Pv Ease of use, requires minimal training of personnel Quick turnaround time to results Individually sealed foil pouches containing: One cassette device One desiccant Two-mark capillary tubes (10/20 µL) Sample diluent (REF SB-R0111, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Flyer Inserts Malaria Pf/Pv Ag Rapid Test Presentation Malaria Pf/Pan Ag Rapid Test Presentation Poster U.S. CDC Malaria Homepage: About Malaria WHO: Malaria Fact Sheets

Send Message

Still searching for
test 20 items?