Jaipur
+918529833535

'symptoms'

Items tagged with 'symptoms'

product image
Rapid Test

Intended Use Scrub Typhus (Tsutsugamushi) IgM & IgG Card is a rapid solid phase immuno-chromatographic assay for the qualitative and differential detection of IgM and IgG antibodies to Scrub Typhus antibodies in human serum / plasma. This test is for in vitro diagnostic use only and is intended as an aid to early diagnosis of Scrub Typhus infection in patient with clinical symptoms. Salient Features Rapid ,visual and qualitative Immunoassay. Differential detection of IgM & IgG antiobodies to Scrub Typhus (Tsutsugamushi) in Human Serum / Plasma. Based on Immunochromatography Technique. See through device for easy interpretation of results. Results with in 20 minutes Shelf life 30 months at 2-30°C Convenient pack size: 20T & 50T. Sensitivity & Specificity: 100% (In house Evaluation)

Send Message
product image
Rapid Test

Intended Use Covid 19 Ag Card Test is designed for in vitro qualitative detection of Covid 19 antigen in human nasopharyngeal, nasal swab specimens. The kit is intended for professional use and as a screening test and is an aid in early diagnosis of SARS COV-2 infection in patients with clinical symptoms. Salient Features Rapid Visual Test for the Qualitative Detection of Covid-19 (SARS-COV-2) antigen in Human nasopharyngeal and nasal swab specimens. Based on Sandwich Immunoassay principle. Results within 20 minutes. Single step test procedure. Evaluated & Validated by ICMR Centre ; Sensitivity -91.5% (<30 CT) & Specificity -100% against RT-PCR. Long Shelf life:30 months at 2-30° C. No Instruments required. Convenient pack sizes . 10T,25T,50T,100T & 200T.

Send Message
product image
Rapid Test

Intended Use Dengue NS1 Antigen self-test is a rapid solid phase immune-chromatographic test for the qualitative detection of Dengue NS1 Ag in human whole blood/serum/plasma. This test is intended to be for home use with self-collected whole blood specimens from individuals aged 18 years or above( or collected by adults for individuals below 18 years of age) as well as for professional use with venous Whole blood/Serum/Plasma samples. This test is for in-vitro diagnostic use only & is designed as an aid in the early diagnosis of dengue infection patients with clinical symptoms. Salient Features Rapid, Visual, Home test for qualitative detection of Dengue NS1 antigen detection in human whole blood/serum/plasma. Finger prick sample can be used. Single test pack. All material to perform the test & its disposal are provided with the kit. Based on Sandwich principle.\ Detection of Dengue in Seronegative stage i.e. from Day 1 of fever. Detection of all 4 serotypes of dengue virus. Reliable diagnosis of both primary and secondary infection. 100% Sensitivity & 100 % Specificity. Shelf life: 30 month at 2-30 °C.

Send Message
product image
Rapid Test

Intended Use Scrub Typhus IgM/IgG/IgA Card is a rapid solid phase immuno-chromatographic assay for the qualitative detection of IgM, IgG& IgA antibodies to Scrub Typhus in human serum / plasma / whole blood. This test is for in vitro diagnostic use only and is intended as an aid to early diagnosis of Scrub Typhus infection in patient with clinical symptoms. Salient Features Finger prick, rapid, visual and qualitative Immunoassay. Detection of all antibodies (IgM, IgG, IgA) to Scrub Typhus (Tsutsugamushi) in Whole blood/serum / plasma. Based on Immunochromatography Technique. See through device for easy interpretation of results. Results within 20 minutes Shelf life 30 months at 2-30°C Convenient pack size: 25 T. Sensitivity & Specificity: 100%

Send Message
product image
Rapid Test

STANDARD Q Ultra Dot HCV Standard Q HCV Ab Test is a rapid chromatographic immunoassay for the qualitative detection of specific antibodies to HCV present in human serum,plasma or whole blood.This test is for in vitro professional diagnostic use and intended as an aid to early diagnosis of HCV infection in patient with clinical symptoms with HCV infection.It provides an initial screening test result.More specific alternative diagnosis methods should be performed in order to obtain the confirmation of HCV infection.

Send Message
product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message
product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message

Still searching for
symptoms?