Jaipur
+918529833535

'statistical calculations'

Items tagged with 'statistical calculations'

product image
Diabetes

Product Features: Better precision, CV < 2.5 % Patented CLE technology enables complete elimination of labile glycohemoglobin ensuring accurate HbA1c results. HbA1c test results in 3.5 minutes with HbA2/HbF flagging. Separation of hemoglobin fractions Complete removal of labile fraction up to 10% No interference of HbF up to 10% No interference of lipemia or icterus, can run on non-fasting patient samples HbA1c reportability presence of HbS, HbC, HbD and HbE Compact bench top model User friendly touch screen operation Sampling from multiple sized primary tubes, including microcapillary collection tubes On board QC functions with Levey-Jennings and statistical calculations Unlimited storage of calibration, QC data and chromatograms No sample preparation required Simple reagent and column replacement Automated maintenance RFID reagent identification and tracking Automatic barcode identification of samples NGSP certified Calibrators and Controls IFCC traceable Complete kit with buffers, calibrator and column Product Application: Hba1c Testing Sampler Handler: 10 Position Rack Loader, positive identification by internal barcode reader Sample Type: Whole blood on EDTA K3 or K2 anticoagulant Haemolysate from EDTA whole blood samples Time for Analysis: Throughput approximately 3.5 minutes between samples Interferences: Complete removal (not separation) of labile up to 10% Sampling System: Sample Aspiration Probe coupled with a high precision, Sample Aspiration Volume: 14.5 µl in whole blood, 670 µl in lysate mode. Pump: 2 high pressure syringe pumps Detector Type: UV-Vis Reagent Traceability: RFID Printer: Built- in thermal printer with possibility to connect to external printer

Send Message
product image
Immunology Analyzer

Product Description: The LisaScan EM Microplate Reader is an economical, compact and versatile 8 channel ELISA reader which can be adapted to various ELISA applications. It is India’s largest selling automated microplate ELISA reader Product Features: Wavelength Range: 400 to 750nm with a dynamic measurement range of 0.0 to 4.0 O.D 100 user-programmable test storage Inbuilt thermal printer for reports & graphs Auto self-check on start-up & external printer connectivity Compatible to various plate geometrics-96 well microplates ( Flat, U & V bottom) Wavelength selection: Monochromatic, bi-chromatic & multi-chromatic* Reading time 8 sec. for single wavelength using 8-channel optics User-friendly inbuilt operation software with 7000 sample test results storage User interface: High Resolution LCD display with 20 Keys Rugged waterproof & membrane panel Computer linked ELISA data management software - Eli-LIMS* CE marked Inbuilt shaking facility,Three Linear Speeds - Low, Medium and Fast Reports can be printed using internal thermal or external printer No need of manual calculations and documentation Documentation ease – Reports can even be stored using optional Eli-LIMS software Computer can be connected Extensive ELISA data management Product Applications: ELISA System type: Open System Plate types: 96 well plates Wells Type: U, V and Flat bottom wells Operating Modes: Absorbance Quantitative Qualitative Semi-Quantitative Kinetic Mode Measurement Modes: Continuous / Step Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set Wavelength Selection: Monochromatic Bi-Chromatic Multi-Chromatic* (Maximum 4) Calculation Modes: Non-linear Standard Cut-off Index Formula Column Subtraction Linear Regression Point to Point Cubic Spline Linear – Log Blank Options: Blank, Control, Assay Validation equations Against Air, Well Plate, Column, Column-mean Row, Row mean Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters Test Programs: 100 totally “open” Test Programs Photometer: Measuring system: 8-Channel optical system Lamp Source: Tungsten Halogen with Lamp saver function Wavelength Range: 400 to 750 nm Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass Dynamic Range: 0.0 ~4.0 OD Photometric accuracy: < 1% at 2.5 OD at 450 nm Photometric resolution: 0.001 OD Linearity: <1% at 2.5 OD at 450 nm Measurement Time: SPEED : 8 Seconds single wavelength NORMAL : 17 Seconds single wavelength Display: High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm Keyboard: Rugged waterproof & membrane panel PC Communication: USB Based Protocol compatible with Eli-LIMS and TNW Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor). Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves. Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored. Lab name in Print-out Lab name in Display Collated reports Print-out of Normal Range along with the result (on external printer only). Graphs can be printed on Thermal Printer Sorted by: Date I.D. Both by Date & I.D. Test Plate ID Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad. Operating Temperature: 20˚ C to 40˚ C Storage Temperature: -10˚ C to 50˚ C Humidity: Max. 80% RH, non- condensing Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter 115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified) Dimension: 502 mm X 369 mm X 216 mm Weight: 7 Kg

Send Message
product image
Clinical Chemistry

XL 1000 with the throughput of upto 1040 tests per hour is the ideal instrument for centralizing the complete biochemistry testing load on a single fully automated platform. Increased walk away productivity and less human intervention make it an ideal analyzer for large laboratories. Equipped with all necessary advanced features that one expects from a high end fully automated chemistry analyzer; sample loading through rack system, cooled calibrator and control carousel, low reading volume of 150 µL, diffraction grating with 15 wavelengths from 340 nm to 800 nm and user-friendly software, to optimize and reliably run the daily lab workload. XL 1000 is a "dream come true" workhorse for laboratories with increased workload and the perfect solution. Fully Automatic, Discrete, Patient prioritized, Random Access Clinical Chemistry Analyzer with throughput of 1040 tests/hour 3 Reagent capabilities 147 long life Hard Glass cuvettes Separate Carousel for STAT samples Onboard refrigeration for reagents Extensive database for storing patient data and Q.C. results Primary tube sampling with bar code identification 9 stage laundry for cuvettes wash 150 samples can be loaded at a time through rack system System Discrete, open, automated, random access, patient prioritized, 1/2/3 reagent system DISPENSING OF SAMPLES AND REAGENTS Sample volume: 2-60 µl (0.1 µl step), 70 µl with ISE Reagent volume: 120 µl – 550 µl 3 dispensing probes ( R1, R2/R3) equipped with liquid -level sensor and crash detector Auto-dilution of samples and calibrators Clot detection Samples Serum, urine, plasma, CSF and other Economy Minimum reaction volume: 180 µl Reusable reaction cuvettes Mixing System 2 independent stirrers 3 user selectable mixing speeds Quality Control 4 levels of control material can be used Levey-Jennigs graphs Twin Plot diagrams for monitoring of systematic and random error Reaction unit with wash station 147 reusable hard glass cuvettes Possibility of replacement of individual cuvette Wash station – cuvette rinsing and drying in nine-step procedure Automatic cuvette blank measurement before analysis Sample Autoloader 23 racks 115 sample positions on automatic autoloader Primary tubes 5, 7 and 10 ml, vacuum system tubes Barcode reader for sample identification 2 Reagent trays With 43 cooled position each Barcode reader for reagent identification 20 ml, 50 ml reagent containers, 5 ml tube with adaptor Option to use one reagent for several test simultaneously Stat Tray 45 positions Can be used for blank, controls, STAT samples Software Convenient user interface Connection to LIS Programmable auto-start from sleep mode including automatic daily maintenance Statistical methods of processing results Data export in selected format Measurement Monitoring Colour indication of sample analysis Possibility of monitoring the reaction in real time Reagent volume monitoring Informative reports on ongoing analyzer status

Send Message

Still searching for
statistical calculations?