Jaipur
+918529833535

'spectral range selection'

Items tagged with 'spectral range selection'

product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 190-1100 nm Optical System Double Beam Spectral Bandwidth 1 nm Wavelength Accuracy 0.1 nm Wavelength Repeatability 0.1 nm Photometric Accuracy 0.3 % T Photometric Range 0-200 % T, -0.3 - 3.0 A, 0-9999 C Photometric Repeatability 0.2 % T Stray Light Less than equal to 0.05%T Stability 0.001 A/h Detector Silicon Photodiode Lamp Type Deuterium Lamp, Tungsten Halogen Lamp Baseline Flatness 0.001 A Noise 0.001 A Data Output Port USB Port Display Graphic LCD (320*240 Dots) Dimensions 630 x 430 x 206 mm Printer Port Parallel Port Weight 26 kg We are the leading manufacturer of a wide range o These products are UV-VIS Spectrophotometer easy to operate and highly appreciated for its durability. Specifications: Wavelength Range 190-1100 nm Mode Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics Scanning Speed Fast / Medium / Slow Wavelength Accuracy 0.1 nm Bandwidth 1 nm Wavelength Reproducibility 0.1 nm Photometric Display Range 0-200 % T, -0.3 - 3.0 A, 0-9999 C Photometric Accuracy 0.3 % T Photometric Repeatability 0.2 % T Stability 0.001A/h @ 500 nm Baseline Flatness 0.001 A Noise 0.001A Stray Light < 0.05% T @ 220nm, 360 nm) Data Output Port USB Printer Port Parallel Port Display Graphic LCD (320*240 Dots) Lamps Deuterium Lamp & Tungsten Halogen Lamp Detector Silicon Photodiode Dimensions(L*W*H) 630 x 430 x 206 mm Net Weight 26 Kg

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range* <0.5%T over entire wavelength range* ,

Send Message
product image
Digital Spectrophotometer

Detector Silicon Photodiode Path Length 10 mm Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Specifications: Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Output % T: 0 to 100%, Abs:0 to 1.999 Conc: 0 to 1999 Detector Silicon Photodiode Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Path length 10 mm Spectral Bandwidth 10 nm Wavelength Resolution 1 nm on Display 2% digit LED Wavelength Accuracy 1 nm Repeatability ±1 nm Read out 3½ digit LED, 1 nm step Operating Temp 5 to 45°C Path length 10 & 50 mm in Model LT-38 Additional Information: Item Code: UV-Mini-1240 Yes! I am interested Spectrophotometer REQUEST CALLBACK Spectrophotometer Ask for Price Product Price :Get Latest Price Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range*

Send Message
product image
Immunology Analyzer

Product Description: The LisaScan EM Microplate Reader is an economical, compact and versatile 8 channel ELISA reader which can be adapted to various ELISA applications. It is India’s largest selling automated microplate ELISA reader Product Features: Wavelength Range: 400 to 750nm with a dynamic measurement range of 0.0 to 4.0 O.D 100 user-programmable test storage Inbuilt thermal printer for reports & graphs Auto self-check on start-up & external printer connectivity Compatible to various plate geometrics-96 well microplates ( Flat, U & V bottom) Wavelength selection: Monochromatic, bi-chromatic & multi-chromatic* Reading time 8 sec. for single wavelength using 8-channel optics User-friendly inbuilt operation software with 7000 sample test results storage User interface: High Resolution LCD display with 20 Keys Rugged waterproof & membrane panel Computer linked ELISA data management software - Eli-LIMS* CE marked Inbuilt shaking facility,Three Linear Speeds - Low, Medium and Fast Reports can be printed using internal thermal or external printer No need of manual calculations and documentation Documentation ease – Reports can even be stored using optional Eli-LIMS software Computer can be connected Extensive ELISA data management Product Applications: ELISA System type: Open System Plate types: 96 well plates Wells Type: U, V and Flat bottom wells Operating Modes: Absorbance Quantitative Qualitative Semi-Quantitative Kinetic Mode Measurement Modes: Continuous / Step Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set Wavelength Selection: Monochromatic Bi-Chromatic Multi-Chromatic* (Maximum 4) Calculation Modes: Non-linear Standard Cut-off Index Formula Column Subtraction Linear Regression Point to Point Cubic Spline Linear – Log Blank Options: Blank, Control, Assay Validation equations Against Air, Well Plate, Column, Column-mean Row, Row mean Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters Test Programs: 100 totally “open” Test Programs Photometer: Measuring system: 8-Channel optical system Lamp Source: Tungsten Halogen with Lamp saver function Wavelength Range: 400 to 750 nm Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass Dynamic Range: 0.0 ~4.0 OD Photometric accuracy: < 1% at 2.5 OD at 450 nm Photometric resolution: 0.001 OD Linearity: <1% at 2.5 OD at 450 nm Measurement Time: SPEED : 8 Seconds single wavelength NORMAL : 17 Seconds single wavelength Display: High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm Keyboard: Rugged waterproof & membrane panel PC Communication: USB Based Protocol compatible with Eli-LIMS and TNW Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor). Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves. Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored. Lab name in Print-out Lab name in Display Collated reports Print-out of Normal Range along with the result (on external printer only). Graphs can be printed on Thermal Printer Sorted by: Date I.D. Both by Date & I.D. Test Plate ID Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad. Operating Temperature: 20˚ C to 40˚ C Storage Temperature: -10˚ C to 50˚ C Humidity: Max. 80% RH, non- condensing Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter 115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified) Dimension: 502 mm X 369 mm X 216 mm Weight: 7 Kg

Send Message
product image
Clinical Chemistry

Product Description: An advanced & versatile semi automated analyzer for all Clinical chemistry, Electrolytes, Immunoturbidimetric assays and Coagulation test Product Features: Semi automated analyzer 56 direct access keys Temperature selection for 20oC - 40oC in steps of 1oC 5 reporting formats Online display of reaction curve Result recalculation Three levels of quality control with Levy Jennings plot 5 reporting formats USB port interface for PC & printer Product Applications: Entire range of Clinical chemistry, Electrolytes, Immunoturbidimetric assays and Coagulation Optical Module: Static photometer with photometric range (340-670) 8 Interference filters 340, 405, 450, 505, 546, 578, 600 and 670 n.m. Silicon photodiode detectors Photometric range from 0 to 3.0 OD Quartz Halogen lamp of 12V, 20W Measuring Module: Unique Triple cuvette system 18 µl Flow cell 10 mm Square cuvette 6 mm Round glass tube with adaptor Peltier temperature control: 20°C-40°C in steps of 1°C Peristaltic Pump Minimum aspiration volume 200 µl Analysis Modes 1-point linear Rate A non-linear 2-point linear 1-point sample blank linear 1-point non-linear 1-point sample blank non-linear 2-point non-linear Absorbance Rate A linear Coagulation Memory: 200 User defined test programs 1000 test result Reagent Blank 3 Levels of QC Result Recall: Collated Reports by Date, ID, Date & ID Test & Date wise Patient Demographics Built-in QC: Daily and monthly monitoring for 3 Levels Levy-Jenning QC graphs Display: High resolution graphics LCD with backlight. View Area: 120 x 92 mm Keyboard: 41 Multifunction Keys and 6 dynamic keys Printer: In built high resolution graphic thermal printer Interface: USB connectivity to PC Direct printer connectivity through USB port Port for External keyboard Power: External Universal SMPS adapter 18V DC, 70W, 115/230V AC (± 10%), 50/60 Hz Size: (mm): 205 (H) x 450 (W) x 300(D) Weight: Approx. 7 Kgs. Optional Accessories: External 16 Position Dry Block Incubator

Send Message
product image
Biochemistry Analyzer

Yumizen CA40 Semi-automated Clinical Chemistry Analyzer: Yumizen CA40 is a semi-automated Clinical Chemistry analyzer with facility to perform Chemistry, Immunoturbidimetry and Coagulation Tests (PT & APTT). It is an ideal solution for small laboratories with the facility to perform a wide range of biochemical tests. Specification:- Semi-automated Clinical Chemistry analyzer with coagulation tests capacity (PT & APTT) 8 incubation positions for chemistry tests and 5 positions for coagulation tests 8-inch colored touch screen display Tri-level Quality Control with Levey-Jennings chart 6 filters with additional 2 open positions Show less

Send Message
product image
Instruments

The NB350 neonatal noninvasive ventilator is specially designed for neonatal ventilation, equipped with comprehensive NIV modes to provide reliable non-invasive respiratory support to meet the various needs of neonatal respiratory management. EasySync™ Technology The patented EasySync™ technology analyzes multi-channel parameters including gas flow and pressure without additional sensors, enabling accurate detection of spontaneous breath and improving synchrony in SNIPPV. The EasySync™ technology leads to a good synchronization performance comparable to electrical activity of the diaphragm (Edi). IOC (Intelligent Oxygen Control) The oxygen saturation of neonates tends to fluctuate, requiring caregivers to frequently adjust ventilator’s FiO2 settings. IOC (Intelligent Oxygen Control) achieves a closed-loop FiO2-SpO2 control by maintaining the patient’s SpO2 within the predetermined range, which reduces the workload of caregivers and improves patient safety. Integrated SpO2 monitoring for neonates in real time.1 Automatically adjust FiO2 setting by adaptive algorithm.2 Steadily maintain the SpO2 of neonates within the preset target range. Comfortable and Reliable Patient-interface The specialized patient-interface for the NB350 comes with a variety of sizes to fit for different clinical applications and patients. The ergonomic design with soft, skin-friendly material fully enhances the comfort of neonates throughout therapies. Bonnet/Headgear The bonnet/headgear integrate a fixings lot (seat) for pressure generator to avoid misposition and disconnection of patient-interface. Skin-friendly and breathable bonnet/headgear. Durable headgear hook-and-loop fastener allows easy and quick re-adjustment of the patient-interface. Infant Jet™ Pressure Generator Adjustable nasal prong/nasal mask positioning to adapt different facial orientations. Specifically designed to facilitate Coanda effect, significantly reducing respiratory resistance. Related Articles

Send Message

Still searching for