Jaipur
+918529833535

'special chemical'

Items tagged with 'special chemical'

product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Thermometers

Since our establishment, we have become the well-known manufacturer and supplier of Chemical Glass Thermometer Mercury Filled. The given product is available on numerous specifications in promised time-frame as per the customer’s demand. Offered product is manufactured as per industry standard by our workforce at our manufacturing unit using finest material. This product is checked on numerous parameters so as to deliver a flawless range. Features: Reliability Durability Fine finish Product Details: Usage/Application To Measure Body Temperature Temperature Range -20 to 150 Degree C Accuracy 1 Degree C Material Glass Theory Glass Thermometer Filling Mercury Filled

Send Message
product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Gluco + Test Strips (Pack of 50 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips require a sample volume of 0.5 μL and taking just 5 seconds to return a test result. XPRESSGLUCO+ strips make the testing experience superior. These Glucometer strips are for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh Accurex Blood Glucose test strips provide accurate results in just 5 seconds. XPRESSGLUCO+ Blood Glucose Test Strips are used with the XPRESSGLUCO+ Blood Glucose Meters. They are intended for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh. They are for testing outside the body (in vitro diagnostic use only). Donot use them for diagnosis of diabetes or testing on neonates. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Safety Information • Discard used test strips and lancets responsibly according to your local regulations. • Keep test strips vial away from children. A child could choke on the test strips. The test strips and their vial contain agents that may be harmful if swallowed. If they are swallowed, promptly see a doctor for immediate assistance. Do not change medication based on the test results without the advice of a physician or healthcare professional. Direction for Use • Prior to first use, ensure that the package is undamaged and closed. • Keep the test strip vial away from sunlight and in a cool, dry place between 5 – 40°C (41 – 104°F). Do not freeze it. • Store test strips in their original pack only. Do not put the test strips in any other container. • Use test strips immediately after removing from the package. • Do not use test strips after the expiration date. • Avoid getting dirt, food or water on the test strip. Do not handle test strips with wet hands. All parts of the test strip should be touched only with dry and clean fingers. • Do not perform blood glucose tests at a temperature below +10°C (50°F) or above +40°C (104°F), or above 85% relative humidity Other Info Each test strip is plasma-calibrated†, requiring a sample volume of 0.5 μL and taking just 5 seconds to return a test result. The test range is 20 to 600 mg/dL (or 1.1 to 33.3 mmol/L) with resolution at 1 mg/dL (0.1 mmol/L). †Plasma-calibrated: Test results produced on capillary whole blood samples by XPRESSGLUCO+ System are compared with the results of the corresponding plasma samples tested by the YSI 2300 Glucose Analyzer, calibrated by YSI 2747 Glucose Standard (a NIST traceable glucose standard). The margin of error of the YSI 2300 Glucose Analyzer measurement is 0.289 mg/dL when the blood glucose concentration is higher than 100 mg/dL, or 0.029 mg/dL when the blood glucose concentration is lower than 100 mg/dL. (1 mmol/L= 18 mg/dL).

Send Message
product image
Glycohemoglobin Analysis

XPRESSGLUCO+ strips make the testing experience superior. These Glucometer strips are for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco + Test Strips (Pack of 100 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips require a sample volume of 0.5 μL and taking just 5 seconds to return a test result. XPRESSGLUCO+ Blood Glucose Test Strips are used with the XPRESSGLUCO+ Blood Glucose Meters. They are intended for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh. They are for testing outside the body (in vitro diagnostic use only). Donot use them for diagnosis of diabetes or testing on neonates. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Safety Information • Discard used test strips and lancets responsibly according to your local regulations. • Keep test strips vial away from children. A child could choke on the test strips. The test strips and their vial contain agents that may be harmful if swallowed. If they are swallowed, promptly see a doctor for immediate assistance. Do not change medication based on the test results without the advice of a physician or healthcare professional. Other Info Each test strip is plasma-calibrated†, requiring a sample volume of 0.5 μL and taking just 5 seconds to return a test result. The test range is 20 to 600 mg/dL (or 1.1 to 33.3 mmol/L) with resolution at 1 mg/dL (0.1 mmol/L). †Plasma-calibrated: Test results produced on capillary whole blood samples by XPRESSGLUCO+ System are compared with the results of the corresponding plasma samples tested by the YSI 2300 Glucose Analyzer, calibrated by YSI 2747 Glucose Standard (a NIST traceable glucose standard). The margin of error of the YSI 2300 Glucose Analyzer measurement is 0.289 mg/dL when the blood glucose concentration is higher than 100 mg/dL, or 0.029 mg/dL when the blood glucose concentration is lower than 100 mg/dL. (1 mmol/L= 18 mg/dL).

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Glucometer Plus Kit Online, it’s a smart Glucometer Machine kit. This Digital Glucometer consists of 1 Blood Glucose Meter, 10 Test Strips, 1 Multilet Lancing Device, 10 Sterile Lancets, 1 Carry Pouch, 1 Warranty Card, Test Strip Insert Sheet, 1 Battery (3V) Gluco Plus Meter is intended for use in the home & in clinical settings. There are different types of Glucometers in Point of Care (POC). XPRESSGLUCO + meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). The system is intended for use outside the body (in vitro diagnostic use only). It should be used only for self-testing blood glucose (blood sugar) and only with fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh. The system is intended for use in the home and in clinical settings. The system should not be used for the diagnosis of diabetes or for the testing of newborns. Blood glucose is measured by an electrical current that is produced when a blood samples mixes with the reagent (special chemicals) of the test strip. The electrical current changes with the amount of glucose in the blood sample. The XPRESSGLUCO+ meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). Safety Information 1. The user should not take any decision of medical relevance without first consulting his or her medical practitioner. 2. Call your doctor immediately if you experience symptoms that are not consistent with your blood glucose test results. 3. High altitudes above than 3,402 meter (11,161 ft) may affect the test results. 4. Temperatures outside the range of 10°C to 40°C (50°F to 104°F) may affect the test results. Do not test beyond of temperature range. 5. Do not perform servicing and maintenance while the meter is in use. 6. No modification of this equipment is allowed. 7. Do not use this meter near cellular or cordless telephones in a call, walkie-talkies, garage door openers, radio transmitters, or other electrical or electronic equipment that are sources of electromagnetic, radiation, as these may interfere with the proper operation of the meter. Direction for Use 1. Wash you hands and puncture sit: Wash your hands in warm, soapy water. Rinse and dry completely . Warm your fingers to increase blood flow. 2. Insert Test Strip : Remove a new test strip from vial. Be sure to tightly replace vial cap after removing test strips. Insert a test strip with the contact bar end entering into the test strip slot first. Push the test strip as far as it will go without bending it. The meter turns on automatically. 3. Hold the prepared lancing device firmly against the side of your fingertip. Press the release button. (NOTE : If you want to do alternative site testing, please refer to the “About Alternative Site Testing (AST)” section. Please consult your healthcare professional before obtaining blood from site other than your fingertip.) 4. Obtain a Blood Sample : Gently massage your finger or puncture site to obtain the required blood volume. To perform the test, you need only 0.5 μL of blood sample. Do not smear the blood sample. To obtain best accurate result, wipe off the first drop of blood and gently squeeze another drop of blood. 5. Apply Blood Sample : When the meter shows the “ ” symbol, apply blood to the opening of the absorbent channel of the test strip where it meets the narrow channel. Blood will be drawn into the test strip. If the test strip confirmation window is full, you will hear a beep. 6. Read Your Result : After the meter counts down from 5 to 1, your blood glucose test result appears along with the unit of measure, date and time. Test result is lower than the target range Test result is within the target range. Test result is higher than the target range *The default target range is 70 mg/dl to 180 mg/dl. 7. Turn Off the Meter : This blood glucose result is automatically stored in the meter memory. Turn the meter off by removing the test strip. Discard the used test strip carefully to avoid contamination. 8. After use, twist off the Lancing Device Cap. Push the exposed tip of the lancet into its Protective Cap. 9. Slide the Lancet Ejector forward and disposing the used lancet in an approved container. Discard the used lancet according to your country’s safety regulations. Replace the Lancing Device Cap. Other Info •Use only XPRESSGLUCO+ Control Solution with your XPRESSGLUCO+ meter. •Check the expiration date on the bottle. Do not use if expired. •Use within a period of 90 days from the date that you first open it. Record the discard date on the control solution bottle when you first open it to serve as a reminder to discard after 90 days. •The control solution ranges are printed on the label of the XPRESSGLUCO+ Blood Glucose Test Strip vial. They are not recommended target ranges for your blood glucose. •For in vitro diagnostic use. •Do not add any liquid to the XPRESSGLUCO+ Control Solution. •Do not take internally or inject.

Send Message
product image
Hematology

Product Specification Instrument Name Haematology Analyzer Automation Fully Automatic Brand Dirui Usage/Application Hospital Differential Type 5-Part Instrument Type Hematology Analyzer Model Name/Number iCount 5TS User Input Touch Product Description Description • A true 5 Part system which has a separate reagents and channel for Basophil measurement. • Special cytochemical stain for bringing out nucleated cell abnormalities. • Semi conductor laser flow cytometry which is a gold standard technique for cell counting and for robustness of the system.

Send Message
product image
Biochemistry Analyzer

Yumizen CA40 Semi-automated Clinical Chemistry Analyzer: Yumizen CA40 is a semi-automated Clinical Chemistry analyzer with facility to perform Chemistry, Immunoturbidimetry and Coagulation Tests (PT & APTT). It is an ideal solution for small laboratories with the facility to perform a wide range of biochemical tests. Specification:- Semi-automated Clinical Chemistry analyzer with coagulation tests capacity (PT & APTT) 8 incubation positions for chemistry tests and 5 positions for coagulation tests 8-inch colored touch screen display Tri-level Quality Control with Levey-Jennings chart 6 filters with additional 2 open positions Show less

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message

Still searching for
special chemical?