product image
Laboratory Usage

Backed by a team of experienced professionals, we are offering Water & Soil Analysis Kits Digital with 7 Parameters. The given product is available on numerous specifications in promised time-frame as per the customer’s demand. Offered product is manufactured as per industry standard by our workforce at our manufacturing unit using finest material. This product is checked on numerous parameters so as to deliver a flawless range. Features: Precisely designed Easy to use Durability Product Details: Application Laboratory Use Brand Swastik Type Soil Analyzer Kit No of Parameter 7 Display Digital Usage To Analyze Water and Soil

Send Message
product image
Laboratory Usage

Soil moisture meter TDR 150 Portable soil moisture meter allows you to obtain readings on the go at the press of a button. Variable rod length options provide soil moisture measurements at your ideal root zone. With new enhancements, the TDR 150 provides significant improvements in performance and measurement accuracy for optimal turf and soil environments. Increased accuracy of soil moisture (Volumetric Water Content) Measures EC (Electrical Conductivity) Measures Turf Surface Temperature Option to add on Bluetooth and GPS Data logger records approximately 50,000 measurements Industry exclusive backlit display Ergonomic handle Data collected with USB flash drive No PC interface needed Powered by AA lithium batteries Ideal for measuring containers on benches Optional IR Temp sensor to measure canopy TDR 150 SPECIFICATIONS Measurement Principle: Time - domain measurement methods Measurement Units: Percent Volumetric Water Content (VWC) Resolution: 0.1% VWC Accuracy: +- 3.0% VWC with Electrical Conductivity (EC) < 2 mS/cm Range: 0% to saturation (Saturation up to about 50% volumetric water depending on soil type) Battery/Life: 4 AA lithium batteries; approximately 100,000 readings without backlight Data Logger: 50,000 measurements EC Range: 0 to 5 mS/cm, Resolution: 0.01 mS/cm, Accuracy: +/- 0.1 mS/cm Temperature Range: -30°C to 60°C, Resolution: 0.1°, Accuracy: +/- 1°C

Send Message
product image
Instruments

We are the Leading Supplier of Colorimeter Bel-ART Klett Summerson Type. Being a quality oriented organization; we offer our wide range of Colorimeter Bel-ART Klett Summerson type, which is finely processed using high grade techniques. We assure that our clients remain satisfied from our qualitative product range. Our offered ranges of Colorimeter Bel-ART Klett Summerson type are precisely designed and engineered by the team of experts. We have a proven track record of never disappointing our customers on the quality front. Our entire product ranges have a long service life and increase satisfaction level of the user. They are sturdy in construction, require less maintenance and give the constant performance to the user with any problem. Usage/Application Industrial Display Digital Automation Type Automatic Material Steel Type Bel-ART Klett Summerson

Send Message
product image
BP Apparatus

Product Details: Material Plastic Automation Type Semi-Automatic Color White Usage/Application Industrial Range 0/20 A 0/20 20/40 40/60 60/80 80/100 Type Hydrometers We are engaged in manufacturing and supplying of Sikes Hydrometers of superior quality range. Hydrometers is a device to measure relative density of liquids such as Grease, oil etc. Components used in a hydrometer are glass frame, cylindrical stem and bulb floating in the mercury fluid.To test the density of a liquid, we use a long glass jar.The jar is filled with liquid and hydrometer is floated inside the fluid.The liquid surface touches the stem of hydrometer at specific point, which indicates specific gravity of that fluid. Features: Alcohol meter (V / V, Volume By Volume) Zeal U.K. at 15.6ºC Range: 0-20, 20-40, 40-60, 60-80, & 80-100 JAWA (Brix) Hydrometers with work Certificate Germany Range: No.1 - 2 to 13 No.2 - 13 to 21 No.3 - 19 to 27 Heavy Liquid Hydrometers, Germany Sp.Gr.1000/2000 & BE 0/70 Light Liquid Hydrometers, Germany Sp.Gr. 700/1000 & BE 10/70 Heavy Liquid Hydrometers, 305 mm Long, Range - 1.000 / 2.000 & 0/70 Baume Light Liquid Hydrometers, 230 mm Long, Range : 700 / 1.000 Baume Hydrometers, Germany at 20ºC Range: 0/10, 10/20, 20/30, 0/20, 0/30, 0/40, 0/50, 30/40 & 40/50 Baume Hydrometers, Digital, Atago, Japan Model PAL-84S, Range : 0.0 - 210 Twaddle Hydrometers German at 60ºF, No. 1, 2, 3, 4, 5, & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 1, 2, 3 & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 4 & 5 Brix Hydrometer w/o Thermometer Germany at 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer w/o Thermometer Germany at 27.5ºC Range: 0/10, 10/20, 20/30, 30/40, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany at 27.5ºC & 20ºC Range: 0/10, 10/20, 20/30, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany GDR, German at 27.5ºC & 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer with Thermometer German with NPL Certificate Brix Hydrometer, Sugar Percent Temp. 27.5ºC Made in West Germany Specific Gravity Hydrometers, Germany at 20ºC 600/700, 700/800, 800/900 & 900/1000 & 800/10001000/1100, 1100/1200, 1200/1300, 1300/14001400/1500, 1500/1600, 1600/1700, 1700/18001000/1200, 1200/1400, 1400/1600, 1600/1800, 1800/2000 800/1000 GDR German Make Sikes Table Book Indian Soil Hydrometer, Zeal England, ASTM 152 H Range: 5 to 60 gm / ltr, Temp: 68ºF Yes! I am interested

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
immunoassayReagents

H-FABP Rapid Quantitative Test Finecare™ H-FABP Rapid Quantitative Test is a fluorescence immunoassay for quantitative measurement of Heart-type Fatty Acid Binding Protein (H-FABP) in human whole blood, serum or plasma. It is used for diagnosis of myocardial infarction.With original qualify control. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ BNP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Brain Natriuretic Peptides (BNP) in human whole blood or plasma. This test is used as an aid to predict the risk of heart failure. STORAGE AND STABILITY 1. Store the test kit at 4 ℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for