Jaipur
+918529833535

'smart maintenance bidirectional lis connectivity hematology analyzer'

Items tagged with 'smart maintenance bidirectional lis connectivity hematology analyzer'

product image
Hematology

The BC-3600 Hematology analyzer features closed tube sampling via a single push button. A built-in large 10.4 inch color touchscreen allows maximum visibility. Hemoglobin analysis is performed using cyanide-free reagent. The analyzer processes up to 60 samples per hour and stores up to 40,000 results with histograms. The barcode reader and optional LIS connectivity enable seamless sample data transmission. Nearly all scheduled maintenance procedures are automated by touch buttons. The intuitive software enhances workflow efficiency and provides operators with a pleasant user experience. Key Features CBC plus 3-part differential, 16 parameters + 3 histograms 60 samples per hour, 1 min per CBC Closed tube sampling, minimize operational biohazard Built In diluent dispenser for predilution mode All-in-one CBC result screen display; results at a glance Touch button maintenance procedures One maintenance reagent only – probe cleaner Storage capacity of 40,000 results with histograms Uploadable QC files; ensure accuracy and time efficiency Parameters WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT,MCV, MCH, MCHC, RDW,PLT, MPV and histograms for WBC, RBC, PLT Principles Electrical impedance method for cell counting and Cyanide - free for hemoglobin Sample Volume Prediluted 20µL Whole Blood 21µL Carryover WBC/RBC/HGB≤0.5% PLT≤1.0% Connectivity 4 USB ports (for external printer, software upgrade, barcode reader,keyboard and mouse), LAN port (1), RS232 (1) Printout Thermal recorder, 50mm width paper, various printout formats, external printer (optional) Product Specification Brand Mindray Differential Type 3-Part Model Name/Number BC 3600 Display Type Large color touch screen Resolution 800x600 Usage/Application Hospital Throughput 60 samples per hour Power Supply AC 100-240V,50/60 +-1Hz Weight 62 lbs Dimension 16 in(W) x 18 in(H) x 18 in(D) Humidity 30%-85% Temperature 15 ~30 Deg C Minimum Order Quantity 1

Send Message
product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Hematology

Direct testing with EDTA tubes Quick Infra Red scanning Results in 10 mins Dynamic sedimentation curve available Internal barcode reader and thermal printer Bidirectional LIS Categories: Hematology Analyzer , Hematology Analyzer Instrument Description Technical specifications Product Specification Automation Automatic Brand CPC Model Name/Number YHLO Vision Pro Sample Mode Whole Blood Operating Voltage 240 V Weight 10.5 Kg Dimension 352mmx365mmx325mm Printer Built-In Thermal Printer Test Speed 20 min/cycle Mode Cycle and Random Test Tube Requirement EDTA tube with a diameter of 12/1 3mm Display Type LCD Touch Screen Display Size 7 inch Barcode Reader Internal barcode reader LIS Bidirectional Connect Frequency 50 Hz Product Description Key Facts Direct testing with EDTA tubes Quick Infra Red scanning Results in 10 mins Dynamic sedimentation curve available Internal barcode reader and thermal printer Bidirectional LIS

Send Message
product image
Clinical Chemistry

TURBOCHEM MAGNA Constant throughput of 300 Tests/hour Discrete random access Bench Top Biochemistry analyzer Independent Probe for Reagents and Sample. Dedicated mixer which enhances faster mixing of reagents and sample High precision results with Low CV% Probe crash prevention with high sensitive liquid level detection of sample/reagents On board laundry with 5 stages of washing Intelligent QC management Bidirectional LIS connectivity Minimal consumable cost for instrument maintenance Remote maintenance, interactive trouble shooting with online application support Constant Throughput of 300 Test/Hour: Guarantees output in any combination Reagent and Sample Tray: Loading more reagent and sample at same time. Intelligent QC Management: Enable QC rules that suit you. Bi-Directional LIS Connectivity: Ensures superior lab process. Specially Designed Mixer: Ensure Homogeneous mixing of reagent and sample.

Send Message
product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Clinical Chemistry

MACHINE-TURBOCHEM PRIME Constant throughput of 180 Tests/hour Discrete random access Bench Top Biochemistry analyzer Probe crash prevention with high sensitive liquid level detection of sample/reagents High precision results with Low CV% Constant throughput of 180 T / Hr Consistently delivering high precision results with low CV% Performs wide range of biochemistry & immunoturbidimetry assays Robust performance with interchangeable reagent position Lowest reaction volume that saves samples and reagents for more number of tests Probe crash prevention with high sensitive liquid level detection of sample/reagents Online condition monitoring, real time fault detection and interactive troubleshooting with i-track QC rules that suits any laboratory requirements Bidirectional LIS connectivity 60 Reagent position assures that the more assays could be performed On board laundry with 5 stages of washing Intelligent QC management 60 Reagent position assures that the more assays could be performed Bidirectional LIS connectivity Minimal consumable cost for instrument maintenance Remote maintenance, interactive trouble shooting with online application support

Send Message
product image
Clinical Chemistry

Product Description: Fully Automated 5 Part Differential Analyser with continuous loading Product Features: Tri angle laser-based flow cytometry for WBC and differentials enumeration 33 reportable parameters including NLR, P-LCC, P-LCR, Mentzer index and RDWI 20 µl sample volume Throughput 80 samples/ hr Large storage capacity of 100000 samples Bidirectional Interfacing Large coloured LCD touch screen of 22 inch Product Application: CBC + Diff Analysis Mode Type: Whole Blood, Predilute, Capillary Autoloader: 60 Tubes; Continuous Loading with Auto-Mixing 33 Parameters: CBC: WBC, RBC, Hb, HCT, MCV MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-SD, PDW-CV, P-LCR, P-LCC, DIFF: Neutrophils % & #, Lymphocytes % & #, Monocytes % & #, Eosinophils % & #, Basophils % & # *ALY % & #, *LIC % & #, *NLR, *Mentzer index and *RDWI *Research use only Principle of Measurement: RBC/PLT/WBC : Electrical Impedance WBC DIFF: Tri-angle Laser Flowcytometry Hb: Cyanide Free Colorimetry MCV: Measured HCT: Calculated Histograms : 3 (RBC/WBC/PLT) Scattergrams : 3 (2D Scattergram), 1 (3D Scattergram) QR Code Reader: For reading sample bar codes & direct input of QC values Sample Volume: Whole Blood: 20 µL Pre- diluted: 20 µL Capillary: 20 µL CBC Mode : 13 µL Linearity Range: WBC : 0 - 300 ( x 103/µL) RBC : 0 - 300 ( x 103/µL) Hb: 0 - 25.0 (g/dL) HCT: 0 - 67 (%) PLT : 0 - 3000 (x 103/µL) Calibrator: ELite H Cal Tri-level Controls: Erba H5 CON L, N, H Open Vial Stability at 2 - 8˚C: 16 Days Throughput: 80 Tests/Hr Quality Control: 500 files with L-J Graph X- Bar Analysis Data Storage: 1,00,000 Results with Graphs Dimension (mm): 650x550x610 Weight (kgs): 59 Reagents: ELite 580 Dil ELite H580Lyse1 ELite H580Lyse2 ELite H580Lyse3 Elite H Clean Interfaces: 4 USB ports ( for connecting external devices including external printers) + 1 LAN Port (HL 7, TCP/IP; LIS connectivity) Operating Environment Temperature: 15-40˚C Humidity: 30-90% Power Requirement: A.C. 100 - 240 V with built-in voltage stabiliser 50/60Hz, 200 VA

Send Message
product image
HEMOGLOBIN METER

Mispa HbX Portable Haemoglobin Analyzer Overview Mispa HbX , Smart Haemoglobin analyzer is a symbol of advanced point of care equipment with modern technology and convenience, designed to deliver high accuracy, quality results with least turnaround time and low maintenance. Best in Class Hemoglobin Meter Mispa HbX, the Smart Haemoglobin Analyzer, is the best example of an advanced point-of-care hemoglobin reader with modern technology. It is easy to use and designed to deliver accurate, high-quality results with the shortest turnaround time and minimal maintenance. This digital Hb meter is one of the best hemoglobin meters available. Working of A Hemoglobin Meter or a hemoglobin reader A hemoglobin meter or a hemoglobin reader measures the amounts of hemoglobin and hematocrit in whole blood. Hemoglobin tests are typically performed to determine the RBC count, the severity of anemia, hematocrit, and other haematological factors. It is widely utilized during blood donations and key decisions such as blood transfusions. HbX works with Spectrophotometry Scattered compensation Technology for accurate and quick results Results will be retrieved with in less than 3 seconds after sample reading starts Sample Required: 7ul Capillary or Venous blood Three Step procedure makes HbX more convenient to use CV value will be less than 1.5 % 6 Hours Battery Backup makes it a hand equipment 2000 Data storage capacity Micro Fluidic cuvettes with 2 year Shelf life

Send Message
product image
Clinical Chemistry

The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins such as cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers: Throughput of up to 1,800 tests per hour to keep pace with workload peaks 200 basic metabolic panels per hour to meet turnaround-time demands Large onboard reagent capacity and optional concentrated reagents to reduce interruptions Optimal standardization of reagents and systems for efficient consumable usage Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 1800® Clinical Chemistry System pushes the limit of productivity in the core lab and meets the turnaround-time (TAT) goals of today’s laboratories. Its extensive menu allows integration of general clinical chemistry testing with testing for drugs-of-abuse, TDM, special chemistry, and specific proteins such as cystatin C and CardioPhase® hsCRP. Automation-ready design Point-in-space aspiration enables connectivity to a track, VersaCell® System. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Peak productivity Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks. Throughput of 200 basic metabolic panels per hour helps to meet turnaround-time demands. Automatic Sample Retain technology lets you perform reruns and dilutions without the need to retrieve primary tubes. Consolidate chemistry testing on one system with a comprehensive menu, consistent cycle times, speed, and open application capability. Total system reliability Minimal-maintenance ISEs Robust hardware and simplified software design, with automatic calibration validation and tracking Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion Direct water connection Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Easy efficiency Large onboard reagent capacity and optional concentrated reagents reduce interruptions. High-resolution touchscreen delivers push-button operation. Reagent pause capability and onboard Sample Pause button make loading easy. Minimal maintenance requirements, including no-maintenance oil bath, reduce hands-on time. Sample integrity checking, include serum indices reporting, short-sample flagging, and clot detection, reducing the need for manual intervention.

Send Message

Still searching for