Jaipur
+918529833535

'skin'

Items tagged with 'skin'

product image
Instruments

The NB350 neonatal noninvasive ventilator is specially designed for neonatal ventilation, equipped with comprehensive NIV modes to provide reliable non-invasive respiratory support to meet the various needs of neonatal respiratory management. EasySync™ Technology The patented EasySync™ technology analyzes multi-channel parameters including gas flow and pressure without additional sensors, enabling accurate detection of spontaneous breath and improving synchrony in SNIPPV. The EasySync™ technology leads to a good synchronization performance comparable to electrical activity of the diaphragm (Edi). IOC (Intelligent Oxygen Control) The oxygen saturation of neonates tends to fluctuate, requiring caregivers to frequently adjust ventilator’s FiO2 settings. IOC (Intelligent Oxygen Control) achieves a closed-loop FiO2-SpO2 control by maintaining the patient’s SpO2 within the predetermined range, which reduces the workload of caregivers and improves patient safety. Integrated SpO2 monitoring for neonates in real time.1 Automatically adjust FiO2 setting by adaptive algorithm.2 Steadily maintain the SpO2 of neonates within the preset target range. Comfortable and Reliable Patient-interface The specialized patient-interface for the NB350 comes with a variety of sizes to fit for different clinical applications and patients. The ergonomic design with soft, skin-friendly material fully enhances the comfort of neonates throughout therapies. Bonnet/Headgear The bonnet/headgear integrate a fixings lot (seat) for pressure generator to avoid misposition and disconnection of patient-interface. Skin-friendly and breathable bonnet/headgear. Durable headgear hook-and-loop fastener allows easy and quick re-adjustment of the patient-interface. Infant Jet™ Pressure Generator Adjustable nasal prong/nasal mask positioning to adapt different facial orientations. Specifically designed to facilitate Coanda effect, significantly reducing respiratory resistance. Related Articles

Send Message
product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message
product image
Glucometer

Item Description The Accu-Chek Softclix lancing device can help make lancing easy. Its rotatable cap offers 11 fixed depth settings for different skin types. Clixmotion technology minimizes any painful side-to-side motion of the lancet, which is why this lancing device is virtually pain-free to use. Benefits and features Virtually pain-free lancing Clixmotion technology controls the lancet’s movement Less side-to-side motion of the lancet means less skin damage Turn the rotatable cap for 11 penetration depth settings for different skin types The Accu-Chek Softclix lancets are precisely manufactured for precise entry Additional specifications Penetration Depth: 11 fixed-depth options, set with the rotatable cap Penetration Range: 0.8 to 2.3 mm Lancing Technology: Clixmotion Technology Weight: 21 g Alternative Site Testing: AST cap provided Needle Diameter: 0.4 mm Gauge: 28 Coating: Silicon How to use the Accu-Chek Softclix lancing device The Accu-Chek Softclix lancing device is small and easy to operate, with one-hand priming and lancing. Pull off the cap. Insert a new lancet into the lancet holder and push it in until it clicks. Press the cap on again until it clicks. Rotate the cap until the desired penetration depth is set. Press the priming button down until it clicks. Press the lancing device firmly against the side of the fingertip. Press the yellow release button. After measuring your blood glucose, pull off the cap and slide the ejector forwards to remove the lancet.

Send Message
product image
Glucometer

FREESTYLE LIBRE PRO Flash Glucose Monitoring System Product Description FreeStyle Libre Pro is clinician's glucose assessment tool that redefines easy. FreeStyle Libre Pro is for the use by Healthcare Professionals only. Easy for patients. Convenient and scalable for clinic. FreeStyle Libre Pro Sensor Small and discreet The FreeStyle Libre Pro sensor is applied on the back of the upper arm. The sensor is water resistant1. Very thin filament Filament is <0.4 mm thick and inserted 5 mm beneath the skin surface to measure glucose levels. Up to 14 days of data Automatically records glucose level every 15 minutes to provide more insightful patterns. Data is blinded from the patient No patient interaction with the sensor is required — designed to integrate with patients' daily lives. FreeStyle Libre Pro Reader The reader stays in the clinic No need to worry about patients losing or damaging components. One reader device starts multiple patients Multiple patients per reader minimizes waiting time and scheduling issues. Lower costs for the clinic The need for only one reader device can help lower your clinic expenses. FreeStyle Libre Pro is an innovative sensor-based ‘Flash Glucose Monitoring’ device that captures glucose readings every 15 minutes for up to 14 days, and gives complete glucose profile report in the form of 'Ambulatory Glucose Profile'. Daily Patterns with Ambulatory Glucose Profile AGP offers a standardized visualization of glucose data that is reliable, predictive, and actionable. The glucose data, generated by Flash Glucose Monitoring over several days or weeks, are collapsed into a single 24-hour period, creating a view of a modal day. This view reveals underlying patterns in glucose variability to a greater extent than using HbA1c by itself. AGP allows healthcare professionals to more effectively visualize and utilize glucose data in the clinical management of diabetes. AGP identifies areas of hyperglycemia, hypoglycemia and glucose variability. Daily Glucose Summary With ‘Daily Glucose Summary’ report, it is easier to know patient’s ‘Time in Target’ Product Specification Model Name/Number Freestyle Libre Pro Averages 14 Days Result Time 3 sec Display LCD Memory Capacity 500 test results Power Supply 1 battery (type CR2032) Sample Type Peripheral Capillary Whole Blood/Venous Whole Blood Weight 45g Including Battery Hematocrit Range 50% Minimum Order Quantity 5 Piece

Send Message
product image
Glucometer

The FreeStyle Libre 2 System is a continuous glucose monitoring system which consists of a reader and a disposable sensor worn on the back side of the arm. This discreet sensor, which is about the thickness of two stacked quarters, is easily applied and stays on the body for up to 14 days. Make sure to check your blood glucose levels by scanning the sensor, it even works through clothing. The FreeStyle Libre 2 System is for adults and children of 4 years and older with diabetes. FreeStyle Libre 2 Sensor Features: Small size and comfortable to wear - About the size of two stacked US quarters, the sensor can be scanned through clothing. Painless & simple application - A very thin filament sits just under the skin to measure interstitial fluid. Accurate sensor readings - No finger-stick calibrations required, and the system has no interference with medications containing acetaminophen. Water resistant - Stays on the body for up to 14 days, and can be worn while swimming, showering, or exercising. Continuous glucose monitoring - Continuously measures the glucose concentration in your interstitial fluid, and stores data for up to 8 hours.

Send Message
product image
Glucometer

MICROLET®NEXT Lancing Device NEW SIMPLY IMPROVED The easy-to-use MICROLET®NEXT lancing device is designed to help minimize pain so you can test with confidence. New and Improved Features to Love: Locking endcap helps prevent accidental lancing 5 clearly visible depth settings Smooth-gliding mechanism to minimize noise Easy-to-use lancet ejector Uses silicone-coated MICROLET®lancets for smooth gliding into the skin Uses MICROLET®Lancets Silicone coated for easier, gentler testing Available in Seven (7) vibrant colours to allow colour coded testing Coloured lancets give you visual feedback to remind you to change your lancets more often

Send Message
product image
Glucometer

Microlet Colored Lancet (Only Lancets) Product highlights Virtually pain-free Can be self-administered Helps to draw a small amount of blood One-time use only Compatible with Microlet 2 and Microlet Next lancing device Information about Microlet Colored Lancet (Only Lancets) Microlet Colored Lancets are used to draw blood for samples. These are small needles that are used to prick the skin to obtain blood. They are virtually pain-free and help to draw just the right amount of blood and not too much Uses Help to draw a small amount of blood (one drop) for testing blood glucose levels Product Specifications and Features: Designed with silicon coating to glide smoothly into the skin Silicone-coated lancets enable piercing with less pain They have easy twist-off caps for simple and smooth testing Sterile tip single-use lancets, lightweight and easy to use Available in different colors Compatible with: Microlet 2 lancing device Microlet Next lancing device Directions For Use: Puncture the finger with a lancet Carefully squeeze out just enough blood Apply on the test strip Safety Information: Discard after use Puncture the finger carefully Store with care Keep out of the reach of children Quick Tips: Puncture the finger quickly in one go Frequently Asked Questions: Can the lancet be used on self? Yes. The lancets are virtually pain-free and can be self-administered Can we change the lancet pin to ensure safety and hygiene? The lancet is for one-time use only. It is to be discarded, and a new lancet will be used every time

Send Message
product image
Hemoglobin Meter

Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Operation Principle: The test strip utilizes Dry Chemistry Colorimeter Method (Azido methaemoglobin Method). When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors avtomatically measure the change in membrane reflectance. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Blood Sample Collection: Fresh or EDTA-anticoagulated capillary or venous whole blood may be used. If an EDTA – treated sample is refrigeratted to come to the room temperature before testing. EDTA treated blood samples should be mixed using end to and inversions at least 8 times prior to use, and should be tested within 24nours Do not use the haemolytic sample anticogulants other than EDTA are not recommended for use. Caution: 1. Same as all diagnostic tests, hemoglobin test results should be evaluated with the specific patient’s condition. Any results demonstrating the inconsistency with the patient’s clinical status should be repeated or supplemented with additional test data. 2. Do not touch the test membrane by hand 3. H12 Hemoglobin Test Strips are one-off product, do not use again Storage & Preparation: 1.H12 Hemoglobin Test Strips should be stored at O C-30 C dry and dark places, 2 C – B C is the best storage environment emperatures recommended. Keep away from direct sunlight and heat, must not be frozen, If the container was stored in refrigerated before first use, please don’t take it back into the refrigerator again after first use. 2. H12 Hemoglobin Test Strips are ready to use. No additional preparation is required 3. Enclosed desiccants with lest strip. Remove only those strips needed for testing. The remaining lest strips should be resealed in their onginal container and used up in 3 months after first use. Do not use lest strips and throw away alter expiry date. 4. Use the strip immediately once taking it out af the container, otherwise the result will be incorrect 5. Do not fold or cut the test strip. 6. Used lest strips cannot be used again, dispose them as normal medical waste Direction for Use Operating Instructions: 1. URIT Hemoglobin Meter, H12 Hemoglobin Test Strip, Lancing Device, and disposable blood taking needle. 2. Test steps: 1) Turn the meter on and input the Code Card. Check the Code Card displaying on the meter to ensure it to match the Code Card printed on the lest strip container. Otherwise, the result is incorrect. 2) Massage the patient’s finger from the knuckle up to the tip to stimulate blood flow. Clean the sample area with alcohol and wipe it dry with a sterile gauze pad. 3) Insert the lest strip into the strip holder with the notched end in first and the hole facing up. 4) Puncture the skin on the lower side of fingertip with blood collection needle, and remove 13-15 TIL of whole biood with capillary or other micro blood collection apparatus. While waiting for the instrument to display the blood drop symbol, quickly add the drops to the test hole on the reagent sheet. Please make sure that the blood drop volume can completely cover the test hole but not overflow the test hole. 5) The meter starts the test automatically after the blood sample disperses Once the lest is in process do nol disturb or move the meter or test strip, or press any key. The test result will display within 12 seconds. Qualtiy Control Procedure: Use only H12 Hemoglobin Test Strip with QC substance to perform QC. The range of QC substance is the numerical range indicated on the label of the QCsubstance or test strips. When to do a QCtest: 1. Whenever you suspect that the meter or test strips are not working properly. 2. If your hemoglobin test results are not consistent with how you feel. Other Info Limitations of test Method: H12 Hemoglobin Test Strip is only suitable for testing fresh or whole capillary blood or whole venous blood containing EDTA anticoagulants. Do not use serum, plasma or arterial blood

Send Message
product image
Glucometer

Sinocare Blood Glucose Uric Acid Strips[Safe AQ UG] Pay attention to your body uric acid index. Fight Gout and Win💪 The validity period of blood glucose test strip is 24 months. Please use it within 6 months after opening the bottle. The validity period of uric acid test strip is 15 months. Please use it within 3 months. Warm Tips : Affected moderately by the environment humidity, the measured value will fluctuate by 15%, which is normal. Please try to store the test strips in an environment with moisture <80% to improve accuracy. Remove a new test strip within the valid expiration of the vial. After taking the strip, immediately cover the vial to avoid losing efficiency. Insert the test strip into the strip slot; the test strip is suggested to use in 3 minutes. Write the discard date (6 months after opening the vial) on the vial label when you open it for the first time. Discard the remaining test strips after the discard date. The test strips are for individual use only. Never reuse a test strip that has applied blood. Please don't store this blood glucose kit where it's too hot or cold. Keeping your fingers clean, wipe the first drop of blood away with a clean tissue, and test with the second drop of blood, which is less likely to be contaminated when using the testing kit. Adjust the depth of your lancing device according to your skin thickness when testing blood sugar.

Send Message

Still searching for
skin?