Jaipur
+918529833535

'single reaction cup'

Items tagged with 'single reaction cup'

product image
Clinical Chemistry

Product Specification Model Name/Number HumaStar 200 Brand Human Automation Fully Automatic Display Digital Dimensions 69 x 76 x 52 cm (WxDxH) Frequency 50/60 Hz Voltage 220-240 or 110-120 Vac Temperature 16-30 Degree C Throughput Up to 200 t/h throughput Weight 51 kg Reaction volume 210-350 il Wash station 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Languages English, French, Spanish Software (other languages can be added) Humidity < 80 % non-condensing Data External computer required (Pentium IV, 2 GHz Mode Open, random-access, STAT Product Description Product Detail : Unique Random-Access Analyzers for Small to Medium Size Laboratories Unique design Unique software architecture Unique features Analysis Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters) Samples Removable sample tray 60 positions: primary tubes 12–12.5x100 mm and 10 mm cups Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates Reagents Removable reagent tray 30 reagent / diluent positions 50 and 20 ml bottles, adapter for tubes and cups Reagent volumes: 5–350 µl Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric Reaction Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air Pipetting Needle shock detector Capacitive liquid level detector Wash station 8-step cuvette wash station Systemic and special washing solution HumaStar 200: 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Optical system 9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day Management 20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet Printouts By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing

Send Message
product image
Hemostasis Analyzer

Product Description: It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting testCuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests. Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centres It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc Key Specifications: Single channel semi-automated hemostasis system It can analyze 1 test at a time Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 216 x 205 x 75 mm Weight : ~1 kg Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored Results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 1000 results for QC determinations Up to 1000 results for patients New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pen drive. Regular backup and file purging is recommended from the USB pen drive to insure rapid operations. USB pen drive, FAT32 formatted

Send Message
product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Clinical Chemistry

Autochem Ingeniious is a semi automated clinical chemistry analyser & has been designed to meet the demands of the research as well as laboratory staff. Compact ergonomic design which is ideal for use in small-to-medium-sized laboratory. In-built Peltier regulated incubation compartment Integrated Coagulation Testing Mode Single & profile wise testing facility Flexible calibration modes Direct access key to run tests Enhanced Patient Data Storage & Retrieval Daily & monthlty QC program Wash & Aspiration function can be controlled using External Keyboard (PS/2 keyboard) roduct Specification Automation Semi Automatic Brand ARKRAY Assays Clinical Chemistry Power Supply Input Voltage : 90-260 VAC, 50/60 Hz Reaction Cuvette Flow Cell Weight <10 kg Power 100 Watts Max Country of Origin Made in India

Send Message
product image
Clinical Chemistry

The Autochem Xact Pro is a Fully Automatic Random Access Clinical Chemistry Analyzer. It is a compact, benchtop analyser with throughput up to 200 tests per hour. First-in-Class On-board Warm-water Laundry System Probe with Collision-Protection System Multi function Probe which works as mixer also Probe with Capacitance based liquid level sensor Robust Multi-functional Software Intelligent" Mixing Arm Removable & flexible Sample - Reagent Disc with 40 Open position for reagent & samples respectively. DESIGNED FOR UNINTERRUPTED WORK FLOW OTHER FEATURES ROBUST MULTI-FUNCTIONAL SOFTWARE Probe with Collision-Protection System Both horizontal and vertical collision protection ensures that system re-starts testing after any unwanted physical intervention. This prevents wastage of reagents, saves test time and increases life of probe Multi functional Probe Probe has flexibility to work even as a mixer in case in-built mixer does not work Probe with Capacitance based liquid level sensor Probe with liquid level sensor checks and indicates the presence of adequate sample or reagent in the container before starting testing process. Thus prevents unwanted interruptions in testing process “Intelligent” Mixing Arm User defined, variable three level mixing speed ensure thorough mixing Accurate performance of regular and immunoturbidimetric assays Independent cleaning station for mixer which prevents carry-over ensuring high precision Removable & flexible Sample – Reagent Disc 40 Open position for reagent & samples respectively Facility to use primary & variable sample cup as well as non fixed position for Sample, Control, Calibrator & STAT samples Two bottle sizes of 18 mL or 5 mL with unique design to reduce reagent dead volume Optional internal Reagent & Sample barcode reader makes the operation user friendly & ensure correct result reporting Reaction tray 60 reusable plastic reaction cuvettes which is also scanned before performing the test which means less recurring cost without compromising on quality. To assure precise results Individual replacement of cuvette offer lower consumable cost REFLEX Testing Functionality Allows user to program Low & High panic value for a particular test which triggers auto-testing of assigned tests which ensures faster and comprehensive reporting Dynamic & Real-time display of Test Running Status for quicker decision making Running status of reagent tray, Sample tray & reaction tray Real-time monitoring of Reaction curve On board inventory management Real-time monitoring of reagent residual volume saves reagent cost & time In-built full QC Program Provision to run 3 levels of control with Levey Jennings graph which gives confidence in reporting with multiple rules (1SD, 2SD and 3SD) Reagent, Calibrator & Control lot monitoring User friendly Bi-Directional LIS Interface

Send Message
product image
Immunology Analyzer

Fully Automated Chemiluminescence Immunoassay Analyzer Introducing iFlash 1200, a chemiluminescence immunoassay analyzer that offers fully automated immunoassay analysis using Magnetic particle-based Direct Chemiluminescence technology. With a high throughput of up to 120 tests per hour and a first result available in just 13 minutes, iFlash 1200 is one of the fastest and most efficient immunoassay analyzers available on the market. The instrument features continuous STAT sample loading capacity with 16 sample positions, continuous reagents loading capacity with 15 reagent positions, and continuous loading of reaction vessels with a capacity of 500 cuvettes. Additionally, iFlash 1200 uses Acridinium Ester Labeled Direct Chemiluminescence for highly accurate and reliable results, and comes with ready-to-use reagents in convenient 2 x 50 tests pack size for simplified testing. Overall, iFlash 1200 is an innovative and versatile immunoassay analyzer that is perfect for laboratories that require high throughput and rapid turnaround times. iFlash 1200 chemiluminescence immunoassay analyzer Key Features: 1.Continuous loading of reagents with convenient pack size of 2 x 50 tests 2.Continous loading of 500 reaction cuvettes for longer walkaway time 3. 4 step magnetic separation for achieving high precision and quality results 4.Non contact vortex mixer-Highly Efficient technology to prevent carryover & cross contamination Additional information General Information Throughput : upto 120 tests/hour Time to First Results :13 minutes Detection Principle Magnetic particle Based Direct Chemiluminescence Chemiluminescence Label :Acridinium Ester Sample System Sample Position :16 sample position Types of Sample tube :Microcup & blood collecting tubes Sample Volume :5~150μL Reagent System Reagent Position :15 reagent positions with onboard refrigeration Reagent Carousel Temp :2-8 °C Reagent Detection :Reagent Level Tracking Reagent Pack : 2 x 50 tests Reagent Carousel Incubation Capacity :48 reaction vessels Incubation Temperature :37°C+-0.3°C Mixing System :Non-Contact Vortex Mixer Operating Conditions Power Supply :100~240V, 50/60HZ Power Consumption :600VA Temperature :10~30°C Weight :120 Kg Reagents iFlash 1200 reagents iFlash 1200 reagents Pack size 2 x 50 Tests 28 days On board reagent stability 28 days Calibration stability Built in Calibrators for all Parameters

Send Message
product image
Clinical Chemistry

Find the Best Semi Automatic Biochemistry Analyzer from Accurex. Buy Acculab At 112 Plus (Semi Auto Biochemistry Analyzer) which is the best Biochemistry Machine with numerous features like Filter Check, Self-check operation for optical filters, Checks the absorbance of each of the 7 filters & free position, Ensures that all the filters are in good working condition. This Biochemistry Analyzer has Improved ergonomic touch screen display, ensures strain free viewing with End point, kinetic, fixed time & absorbance mode. FILTER CHECK • Self-check operation for optical filters. • Checks the absorbance of each of the 7 filters & free position. • Ensures that all the filters are in good working condition. WORKLIST • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. LAMP SAVING • Lamp saving option available ensuring long lamp life. • The lamp can be turned off in case of sporadic sample workload ALARMS • Audio alarm is sounded when results are higher (S) or lower (L) than reference range ensuring that all abnormal samples are flagged for further review. • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design Methodology: End point, kinetic, fixed time & absorbance Calibration: Single standard/multi-point linear/multi-point non-linear Programmable channels: 112 Memory: 3200 results Quality control: Comprehensive QC software with L-J graph Light source:Quartz-Halogen lamp 12V / 20W Photometric range: 0.0000 to 3.0000 Abs, Resolution : 0.0001 Abs : Drift : 0.002 Abs/hour Wavelength range: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm & 1 free optional position ; Half Bandwidth < 8 nm : Stray light : < 1.0 % at 340 nm, Stainless steel body with quartz window; Optical path 10 mm Flowcell: Stainless steel body with quartz window; Optical path 10 mm Measuring volume: 32 μl Programmable aspiration volume:: 500-2000 μl Temperature control: Peltier elements : 25°C, 30°C & 37°C ±0.1°C Input: Ergonomic LCD touch screen display Printer: Built-in high speed thermal printer Interface: RS-232 serial port Dimension / Weight: 450 x 360 x 140 mm / 11.5 kgs Operating environment: Temperature: 15-30°C ; Humidity: 20-80 % Power requirement: AC 110-220 V ±10%, 50/60 Hz Safety Information • The position of the LCD display has been designed to reduce cervical (neck muscle) strain during continual use. • The aerial view display design makes it possible to view the screen from multiple perspectives, (standing or sitting, with equal clarity). Direction for Use • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. Other Info • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design

Send Message
product image
Rapid Test

Buy AccuTest HCV Rapid Card Test (30 Tests) Online from Accurex. HCV means Hepatitis C Virus which is a is a small, enveloped, positive-sense, single-stranded RNA virus. Hepatitis C symptoms are fever, fatigue, decreased appetite, nausea, vomiting, abdominal pain, dark urine, pale feces, joint pain and jaundice. HCV test is a rapid Chromatographic Immunoassay work on principle of the double antigen sandwich technique, Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. AccuTest HCV Test is a rapid Chromatographic Immunoassay for the Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. Hepatitis C Virus (HCV) is a small, enveloped, positive-sense, single-stranded RNA virus. Antibody to HCV is found in over 80% of patients with well documented non-A, non-B hepatitis. Conventional methods fail to isolate the virus in cell culture or visualize it by electron microscope. Cloning the viral genome has made it possible to develop serologic assays that use recombinant antigen, multiple antigens using recombinant protein and/or synthetic peptides have been added in new serologic tests to avoid nonspecific cross-reactivity to increase the sensitivity of HCV antibody tests. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or quest Principle: AccuTest HCV Rapid Hepatitis C Virus Test (Serum/Plasma/Whole Blood) is a lateral flow chromatographic immunoassay based on the principle of the double antigen-sandwich technique. The membrane is coated with recombinant HCV antigen on the test line region of the device. During testing, the serum/plasma or W.Blood specimen reacts with HCV antigen coated particles. The mixture migrates upward on the membrane chromatographically by capillary action to react with recombinant HCV antigen or membrane and generate a colored line. Presence of this colored line indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear at the control line region, indicating that the correct volume of specimen has been added and membrane wicking has occurred. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Safety Information •Positive: If a distinct purple line is formed at the test one marked ‘T’ (Test Line) and the Control Zone marked ‘C’ (Control Line) the test result is positive, indicating the sample contains Hepatitis C antibody. The interpretation of test results (+ve for hepatitis) remains unchanged even if there is a difference in intensity of color in positive line and control line as is many a time found. •Negative: If a distinct purple line is formed only at the control zone marked ‘C’ (control line) the test result is negative • Invalid: A total absence of color in both © and (T) regions or no colored band appears on the control © region is an indication of procedure error and/or the test reagent has deteriorated. Repeat with a new test kit. Direction for Use Test Procedure 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Other Info Storage and Stability AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch.

Send Message

Still searching for
single reaction cup?