Jaipur
+918529833535

'serum specimens'

Items tagged with 'serum specimens'

product image
immunoassayReagents

INTENDED USE The Finecare™ SAA Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of serum amyloid A (SAA) in human whole blood, serum or plasma. This test is used as an aid to assist in the diagnosis of infection and inflammation. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Rapid Test

Intended Use Dengue NS1 Antigen self-test is a rapid solid phase immune-chromatographic test for the qualitative detection of Dengue NS1 Ag in human whole blood/serum/plasma. This test is intended to be for home use with self-collected whole blood specimens from individuals aged 18 years or above( or collected by adults for individuals below 18 years of age) as well as for professional use with venous Whole blood/Serum/Plasma samples. This test is for in-vitro diagnostic use only & is designed as an aid in the early diagnosis of dengue infection patients with clinical symptoms. Salient Features Rapid, Visual, Home test for qualitative detection of Dengue NS1 antigen detection in human whole blood/serum/plasma. Finger prick sample can be used. Single test pack. All material to perform the test & its disposal are provided with the kit. Based on Sandwich principle.\ Detection of Dengue in Seronegative stage i.e. from Day 1 of fever. Detection of all 4 serotypes of dengue virus. Reliable diagnosis of both primary and secondary infection. 100% Sensitivity & 100 % Specificity. Shelf life: 30 month at 2-30 °C.

Send Message
product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite hCG Combo Rapid Test is a lateral flow chromatographic immunoassay for the early detection of pregnancy, by providing a quick direct visual test for the placental hormone, hCG in human serum, plasma and urine. It can be performed within 5-10 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite hCG Combo Rapid Test is not intended for quantitative results, nor for over the counter (OTC) sales. It is intended to meet all requirements for yielding rapid, easily read, qualitative results for the purpose of early pregnancy detection via assay of hCG, a placental hormone that may be present in human serum, plasma or urine. The hCG detection limit the OnSite hCG Combo Rapid Test is 12.5 mIU/mL in serum or plasma specimen, and 25 mIU/mL in urine specimen. It is designed for professional use only, and provides only preliminary analytical data. For a final diagnosis of pregnancy, a more specific alternative clinical method must be used to obtain a confirmed analytical result. Clinical accuracy: In comparison with a reference chemiluminecsence or ELISA, hCG detection is 100% sensitivity and 100% specificity in urine specimens 100% sensitivity and 99.5% specificity in serum specimens Analytical sensitivity: 100% positive detection rate at 12.5 mIU/mL in serum/plasma specimens and 100% positive detection rate at 25 mIU/mL in urine specimens Analytical specificity: no cross reactivity with 1,000 mIU/mL human luteinizing hormone (hLH), 1,000 mIU/mL human follicle stimulating hormone (hFSH), and 1,000 mIU/mL human thyroid stimulating hormone (hTSH) Dose hook effect: no dose hook effect was observed for hCG at concentrations up to 500,000 mIU/mL in urine specimens Interference: No interference was seen with 35 biological and chemical analytes commonly found in OTC, prescriptions or abuse drugs in urine or serum/plasma specimens, as well as pH 4-9 (see detail in the package insert) Shelf life: 24 month Kit box package: 1. Individually sealed foil pouches containing; a. One dip strip device b. One desiccant 2. One package insert (instruction for use) Tube package: 1. Strip Package 2. One desiccant 3. One package insert (instruction for use) CTK Products at a Glance Drugs.com: Overview of Human Chorionic Gonadotropin Inserts

Send Message
product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message
product image
Rapid Test

The OnSite Malaria Pf/Pv Ab Combo Rapid Test is a lateral flow chromatographic immunoassay for the simultaneous detection and differentiation of antibodies including IgG, IgM and IgA to Plasmodium falciparum (Pf) and Plasmodium vivax (Pv) in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimens Utilizes highly purified antigen to ensure test sensitivity and specificity Detects total antibodies to Pf and Pv Ease of use, requires minimal training of personnel Quick turnaround time to results Individually sealed foil pouches containing: One cassette device One desiccant Two-mark capillary tubes (10/20 µL) Sample diluent (REF SB-R0111, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Flyer Inserts Malaria Pf/Pv Ag Rapid Test Presentation Malaria Pf/Pan Ag Rapid Test Presentation Poster U.S. CDC Malaria Homepage: About Malaria WHO: Malaria Fact Sheets

Send Message
product image
Rapid Test

The OnSite hCG Combo Rapid Test is a lateral flow chromatographic immunoassay for the early detection of pregnancy, by providing a quick direct visual test for the placental hormone, hCG in human serum, plasma and urine. It can be performed within 5-10 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite hCG Combo Rapid Test is not intended for quantitative results, nor for over the counter (OTC) sales. It is intended to meet all requirements for yielding rapid, easily read, qualitative results for the purpose of early pregnancy detection via assay of hCG, a placental hormone that may be present in human serum, plasma or urine. The hCG detection limit of the OnSite hCG Combo Rapid Test is 12.5 mIU/mL in serum or plasma specimen, and 25 mIU/mL in urine specimen. It is designed for professional use only, and provides only preliminary analytical data. For a final diagnosis of pregnancy, a more specific alternative clinical method must be used to obtain a confirmed analytical result. Clinical accuracy: In comparison with a reference chemiluminecsence or ELISA, hCG detection is 100% sensitivity and 100% specificity in urine specimens 100% sensitivity and 99.1% specificity in serum specimens Analytical sensitivity: 100% positive detection rate at 12.5 mIU/mL in serum/plasma specimens and 100% positive detection rate at 25 mIU/mL in urine specimens Analytical specificity: no cross reactivity with 1,000 mIU/mL human luteinizing hormone (hLH), 1,000 mIU/mL human follicle stimulating hormone (hFSH), and 1,000 mIU/mL human thyroid stimulating hormone (hTSH) Dose hook effect: no dose hook effect was observed for hCG at concentrations up to 500,000 mIU/mL in urine specimens Interference: No interference was seen with 35 biological and chemical analytes commonly found in OTC, prescriptions or abuse drugs in urine or serum/plasma specimens, as well as pH 4-9 (see detail in the package insert) Shelf life: 24 month Individually sealed foil pouches containi a. One cassette device b. One plastic dropper c. One desiccant One package insert (instruction for use) CTK Products at a Glance Drugs.com: Overview of Human Chorionic Gonadotropin Inserts CATALOG # PRODUCT QUANTITY SPECIMEN R1001C hCG Combo Rapid Test CE 30/kit S/Urine OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT QUANTITY SPECIMEN R1001S hCG Combo Rapid Test (Strip) CE 50/kit, 100/kit S/Urine

Send Message
product image
Rapid Test

The OnSite Duo HSV-1/2 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) and herpes simplex virus 2 (HSV-2) in human serum, plasma or whole blood. This test can be performed in 10 minutes by minimally skilled personnel without the use of laboratory equipment. This test is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with HSV-1 and/or HSV-2. The OnSite Duo HSV-1/2 IgG/IgM Rapid Test uses HSV-1 glycoprotein G1 and HSV-2 glycoprotein G2 for the specific detection and differentiation of IgG and IgM antibodies to HSV-1 and HSV-2 in serum, plasma and whole blood. An HSV-1 and/or HSV-2 IgM positive result indicates an active infection, which may be primary or recurrent. An HSV-1 and/or HSV-2 IgG positive result indicates a recent or past infection. However, a negative test result does not preclude the possibility of infection with HSV-1 and/or HSV-2. Any interpretation or use of this preliminary test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Alternative test method(s) should be considered to confirm the test result obtained by this device. Clinical accuracy: 90.6% sensitivity and 91.4% specificity for anti-HSV-1 IgG detection 93.8% sensitivity and 96.0% specificity for anti-HSV-2 IgG detection 85.0% overall agreement for anti-HSV-1 IgM detection comparing to commercial ELISA 100% overall agreement for anti-HSV-2 IgM detection comparing to BBI Panel (PTH202) Positive rate on random clinical specimens:8% for IgG anti-HSV-1 and 4.9% for IgM anti-HSV-1 (n=10,000); 4.6% for anti-HSV-2 IgG and 1.7% for anti-HSV-2 IgM Cross reactivity: no cross reactivity with the following disease states or special conditions, respectively: palladium, H. pylori, Dengue, Malaria, Typhoid, Toxoplasma, Rubella, CMV, hCG, TB, HAV, HBV, HCV, HEV, HIV, ANA, HAMA, RF (up to 1,000 IU/mL) Interference: No interference was seen with Albumin 60 g/L , Hemoglobin 2 g/L, Bilirubin 20 mg/dL, Heparin 3,000 U/L, Creatinine 442 µmol/L, Salicylic acid 4.24 mmol/L, EDTA 3.4 µmol/L, Sodium citrate 8%, Glucose 55 mmol/L Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use)

Send Message

Still searching for
serum specimens?