Clinical Chemistry

With the built-in oxygen concentration monitoring system and effective cable management system, the HyPort R80 is capable of creating a reliable and streamlined ICU environment to ensure patient safety. Recovery The lighting system of the HyPort R80 aims to create a comfortable, near-natural light ICU environment to enhance patient recovery. 1234 1 Circadian Light Simulating 24-hour natural daylight change to reflect circadian rhythm. 2 Examination Light Up to 10,000 lux, 5-level adjustable illuminance meets various needs of head and abdominal examination. 3 Reading Light Effectively avoid invalid glare to meet the reading needs of rehabilitating patients. 4 Navigation Light Providing enough lighting with less glare for medical staff’s easy observation and intervention. Efficiency The HyPort R80 is a highly integrated bedside device management system that helps caregivers organize medical devices to meet various clinical needs. It makes efficient use of beside space with a series of easy-to-use designs, enabling a more efficient workflow for medical staff. Folding-shelf design Suitable for both portable ventilators and integrated ventilators. p46-s3-2-web Bag-valve-mask management Making sure bag valve mask is easy to access and ready for emergency situations anytime when needed. p46-s3-3-web Partition management The pump separation layout allows medical staff to easily identify infusion pumps and feeding pumps. p46-s3-4-web Smooth movement The advanced braking technology ensures stability of the column when moving. NextPrevious Variety The HyPort R80 has been designed to meet the demands of different ICU layouts to create a safer, more efficient and comfortable ICU environment with patient-centric design.ICU double room solution A Product Specification Usage/Application Hospital Brand Mindray Model Name/Number HyPort B80 Features 60 Degreepanel interface for easier plug-in of gas and electricity Color White Panel Interface 60 Degree Product Description Gas and electricity separated 60°panel interface for easier plug-in of gas and electricity Flexible movement of sliding and rotating of the distributions Additional accessories for better management of details Considerate lighting option Safer and more effective workflow Gas and electricity separated 60°panel for easier plug-in of gas and electricity Better management Customized drawer solutions Wire basket - dfferent size options available Cable management solutions

Send Message
product image
Instruments

To meet variegated demands of our esteemed patrons, we are engaged in offering an exclusive range of Barigo Hygrometer. This hygrometer is used in meteorological science to measure the humidity. Offered hygrometer is manufactured with best quality components and contemporary techniques keeping in mind the set norms of industry. As well offered hygrometer is available at competitive rates in a promised time frame. Features: Excellent performance Least maintenance Application specific design Other Details: Thermo + Hygro + Barometer Barigo, Dial Type GERMAN Make Cat No.3780 Fibre Boby, 180 x 90 mm Hygrometer 85 mm Dial Type Barigo German Model 409 - Range 0-100 % R.H roduct Details: Application Industrial Material Glass Accuracy 0.01 Display Analog Model 409 Range 0-100 % R.H

Send Message
product image
Distance Meter Digital

Product Details: Weight 305 g Model No GM-06 Measuring Geometry 60 Degrees Power Supply Batter, 4 X 1.5 VA Display 4 digits backlit LCD Range 0.1 to 200 gloss units We are offering Digital Gloss Meter which is widely used in Floor maintenance, Surface cleaning quality control, Stone and tile gloss measurement, Checking printed matter, Quality control of paint and ink, Polished metal surface , measurement (chrome plating), Inspection of paint protection and waxing, Auto-body paint inspection,Surface inspection of plastic moldings, Evaluation of detergents and washers,Checking masonry and washers, Checking building exteriors. Specifications: Accuracy: ±1.0 gloss unit ( against reference standard ) Resolution: 0.1 gloss unit Repeatability: ±0.5 GU(0 ... 99.9) Measuring Area: mm ellipse Data Memorized: groups Data Output: RS 232 C serial interface Dimensions: Main unit: 156 x67x28 mm Separate Sensor: 58x28x108 mm Weight : About 305g ( including fitted batteries ) Working condition: Temperature range 0 - 40¿¿¿ and Humidity up to 85%.

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180T is a fully automated Glycohemoglobin analyzer based on HPLC (High Performance Liquid Chromatography) and is highly effective for ß-thalassemia testing. Measurement speed: 3.5 minutes/test Measurement Item as below HbA2 HbF HbA1c (Stable HbA1c, S-A1c), HbS, HbC, HbE and HbD can be detected. Column design with no more pre-filter change. Color LCD with reagent level, graphs on screen. Samples Whole blood or hemolysis sample Measurement items HbA1c(Stable HbA1c, S-A1c), HbA2 and HbF (HbS, HbC, HbE and HbD can be detected.) Reagents *1 ELUENT 80A, ELUENT 80B, ELUENT 80CT and HEMOLYSIS WASHING SOLUTION 80H Column *2 COLUMN UNIT 80T Measurement principle Reversed-phase cation exchange chromatography Detection method Dual-wavelength colorimetry (wavelengths measured: 420nm/500nm) Resolution 0.1% Ratio, 1 mmol/mol Measurement range *3 HbA1c : 3-20%, 9-195 mmol/mol HbA2 : 2-10% HbF : 0-100% Guaranteed measurement range *4 HbA1c : 4.2-12.9%, 22-117 mmol/mol HbA2 : 2.4-6.3% HbF : 0.1-14.3% Processing speed 210 seconds per sample Sample consumption Approx.14μL(whole blood) Sample container Blood collection tube (12.3 to 15mm diameter) × ( 75 to 100mm length) Sample cup(500μL) Sampling method Cap-Piercing Rack type ARKRAY racks Number of measurement samples One-way transportation (factory set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approx. 39℃ Display Color graphic LCD with backlight Memory capacity 500 test results ( including calibration results ) Built-in Printer Termal printer, 58mm thermal paper External output Serial 1 port (Can be optionally used as an Ethernet port.) Measurement conditions Temperature : 15-30℃ Humidity : 20-80% relative humidity (non-condensing ) Required sample volume Blood collection tube : Minimum 10mm away from the bottom Sample cup : 400μL or more Warm-up time Maximum 30 min. Dimensions 530(W)×530(D)×530(H)mm (Not including the hemolysis washing solution bottle) Weight Analyzer: Approx. 39kg, Sampler: Approx. 4kg Power supply AC100V-240V ±10% 50/60Hz Power consumption Max. 300 VA *1, *2 Reagents and column are sold separately from HA-8180T analyzer. *3 Error-free measurement ranges. *4 Guaranteed ranges for obtaining results equivalent to those from HA-8160 TP mode measurement. ※Design and specications may be changed without prior notice

Send Message
product image
Hematology

Product Specification Instrument Name Haematology Analyzer Automation Fully Automatic Brand Dirui Usage/Application Hospital Differential Type 5-Part Instrument Type Hematology Analyzer Model Name/Number iCount 5TS User Input Touch Product Description Description • A true 5 Part system which has a separate reagents and channel for Basophil measurement. • Special cytochemical stain for bringing out nucleated cell abnormalities. • Semi conductor laser flow cytometry which is a gold standard technique for cell counting and for robustness of the system.

Send Message
product image
Glucometer

Details - Sinocare -Caring for love Virtually pain free glucose testing , 1 Meter (mmol/L) + 1 Lancing device , 1 PU bag ,50 Test strips ,50 L Diabetes Testing Kit/Blood Glucose Sugar Test Kit with Code-free Strips & Case in mmol/L or mg/dL ?????? Blood Glucose Testing Kit: This kit covers Sinocare blood glucose monitor Safe-Accu & Strips & Lancets & Painfree lancing device & Case & User manual. A set of equipment is provided to meet all your needs when measuring blood sugar. ?????? High-cost Performance: A affordable, low price, full-featured, suitable device for long-term use. ?????? Precise & Easy to Use: Code-free test strips, only 10s testing time, 0.6 microliters blood sample volume. The test strips have advanced technology and stability. Results are given in the UK standard measurement of mmol/L. ?????? Convenient: This product has the advantages of exquisite and lightweight. Easy to carry anywhere. It allows you to easily test your blood sugar while you are on a business trip or traveling. ?????? Large Memory Capacity: The memory capacity reaches 200, which can display the data average of 7 days, 14 days, and 28 days. You can easily access historical data at any time. Kindly pay attention: please use the sinocare blood sugar test strips within the valid time (six months after opening). Don't store the blood glucose kit where it's too hot or too cold. Keeping your fingers clean, wipe the first drop of blood away with a clean tissue, test with the second drop of blood, which is less likely to be contaminated when using the testing kit. Results from alternative sites don't reflect your current blood glucose level. Adjust the depth of your lancing device according to your skin thickness when testing blood sugar. 0.6 micro liters When you use our blood glucose test kit to take a blood glucose home test, you only need 0.6 micro liters blood to relieve your pain. Deigned-friendly The clear large screen design is convenient for the elderly to read their own measurement values after blood testing. The strip ejection button can ensure that you are not infected by the blood sugar monitor strip. Fast and Convenient This blood glucose monitor can quickly get a value within 5 seconds without coding. Each measurement value will be recorded according to the current specific time, which is convenient for you to track. Specifications: Brand Name SINOCARE Origin China Item Type Blood Glucose Material Medical PVC Model Number Safe-Accu Size 161 x 112 x 50 mm Item Name Blood Glucose Meter Blood Volume 0.6ul Test Strips Packing Separated Packing Test Time 10s Measurement Unit mg/dL & mmol/L Test Range 1.1-33.3mmol/L Memory 200 Set with Date & Time

Send Message
product image
Clinical Chemistry

EM 360 is a Fully Automated Clinical Chemistry Analyser which is time tested and proven technology. It is designed to provide the most demanding productivity, speed and operational ease. EM 360 with a throughput of 360 tests/hour offers flexibility in operation and rugged performance to win against high workload, tight deadlines, multiple tasks and complexity of testing. It yields high quality results for virtually any biochemistry test to deliver quick, efficient and consistent performance. Product Features: Automated, Discrete, Patient prioritized, Floor model Based on proven technology, Diffraction Grating Separate probes for Reagent R1 & R2 and dedicated probe for sample Low reading volume of 200 µl only Onboard cooling for reagents to enhance the reagent stability Barcode for reagents & samples (Optional) Wide test menu Product Applications: End Point Reactions: Glucose, Cholesterol, Triglycerides, Albumin, Total Protein, Uric Acid, Calcium, Magnesium, Bilirubin Total, Bilirubin Direct Kinetic Reactions: SGOT, SGPT, GGT, LDH, CK, CK MB, ALP, ACP, Amylase, Lipase Two Point Rate Reactions: Urea, Creatinine Immunoturbidimetric Chemistries: RA, CRP, ASO, Direct HDL, Direct LDL, Apo A, ApoB, Lp (a) Special Chemistries: HbA1c, Iron, Ferritin, Phosphorus, Microprotein, Ammonia, Bicarbonates System Type: Discrete, automated, random access, patient prioritized clinical chemistry analyzer Throughput: 360 tests / hour photometric and 600 tests / hour with ISE* (*optional ISE with Na+, K+, Cl-, Li+) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry (optional) Barcode Reader: For reagents and samples (optional) Reaction Tray: 60 hard glass cuvettes Reaction Mixing: Stirrer with variable speed Minimum reaction Volume: 150 μl with maximum 200 μl reading volume On-board Laundry: 5 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 nm) OD Range: 0.0 - 3.0 Light Source: Halogen lamp Detector: Silicon photo-diode Water Consumption: < 10 litres Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profile and unlimited calculation items Quality Control: QC plot data with QC rules. Provision for lab mean. Twin plot Calibration: K-Factor, Linear (1, 2 point & multipoint), 4P and 5P Logit-log, cubic spline, exponential, polynomial, On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimension (mm): Approx. 675 (W) x 840 (D) x 1120 (H) Weight: Approx. 150 kgs. SAMPLE HANDLING Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: 82 positions for samples, blank , controls, calibrators, STAT sample Sample Pipetting: 2 - 70 µl (adjustable in 0.1 µl step) for Biochemistry, 70 µl fixed for ISE Capacitance probe with liquid level sensing & vertical obstruction detection, serum indices Auto Rerun: Repeat with same, increased or decreased volume ( upto 1:150) Sample Tubes /Cups: Primary tubes of 5 ml, 7 ml, 10 ml and sample cups REAGENT HANDLING Reagent Tray: 50 positions for reagents with onboard cooling Reagent Pipetting: R1: 50 - 300 µl (adjustable in 1 µl step) R2: 10 - 200 µl (adjustable in 1 µl step) Capacitance probe with level sensing & vertical obstruction detection SYSTEM INTERFACE: Analyzer-PC: USB PC - Host Computer: Bidirectional TCP / IP & RS - 232 PC - Printer: USB Operating System: Windows Based Database: Unlimited Results

Send Message
product image
Clinical Chemistry

Product Description: XL-640 with CRS is a random access, discrete, patient prioritized, fully automated clinical chemistry analyzer with autoloader designed to meet the needs of today’s modern clinical laboratories with high workload. Once samples are loaded, it is a complete walk-away system. XL 640 CRS is designed to operate smoothly over the long haul and to deliver consistent quality report. Product Features: Throughput of 400 tests/ hour (Photometric) and 640 tests/hour with ISE 56 Reagent Positions with On-board cooling for reagents 162 Sample positions with /Autoloader Separate probes for reagent R1 & R2 and dedicated probe for sample Clot detection for sample probe, Reflex testing and Serum Indices identification 72 permanent hard glass cuvettes with On-board Laundry Automatic dilution for high abnormal samples & Auto Rerun facility Extensive QC Programmes with Levy –Jennings Curve & QC rules. Automatic calculation for Mean SD & CV% Direct loading for primary tubes Touch screen User Friendly GUI with Bi-directional connectivity. System General System Type: Automated, Discrete, Random Access, Patient Prioritized Clinical Chemistry Analyzer with Autoloader Throughput: 400 photometric tests/hour & 640 tests/hour with ISE (*optional ISE with Na, K, Cl, Li) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry(optional) Barcode Reader: Both for Samples & Reagents (Optional) Reactions Tray: 72 hard glass cuvettes Reaction Mixing: Dual Stirrer with variable speed Reading Volume: 180 µl On-Board Laundry: 6 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700 & 750 nm) O.D. Range: 0 - 3.0 Light Source: Halogen Lamp Detector: Silicon Photodiodes Water Consumption: < 14 liters/hour Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items Quality Control: Q.C. plot data with Q.C. Rules. Provision for lab mean. Twin plot. Caliberation: K- factor, Linear (1,2 point and multipoint) 4P and 5P Logit-log, Cubic spline,exponential, polynomial. On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimensions: Approximately 897 mm (w) x 655 mm (D) x 1170 mm (H) Weight: Approximately 200 Kg Sample Handling Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: upto 162 positions for samples/STAT/calibrator/controls with Autoloader Sample Pipetting: 2-70 µl (adjustable in 0.1 µl steps) for biochemistry,70 µl fixed for ISE capacitance probe with liquid level sensing and vertical obstruction detection , clot detection and serum indices and Reflex Testing Auto Rerun: Repeat with same, increade and decresaed volume (upto 1:150) Sample Tubes/Cups: Primary tubes of 5 ml, 7ml and 10 ml and sample cups Reagent Handling Reagent Tray: 56 positions for reagents with on-board cooling Reagent Pipetting: R1: 60 - 300 µl (Adjustable in 1 µl step) R2: 0 or 10 - 300 l (Adjustable in 1 µl step) Capacitance probe with level sensing and vertical obstruction detection System Interface Analyzer-PC: USB PC- HOST Computer: Bidirectional TCP/IP and RS - 232 PC- Printer: USB Operating System: Windows based with Touch Screen User Friendly GUI Database: Unlimited Results