Jaipur
+918529833535

'sd check gold 2 glucometer'

Items tagged with 'sd check gold 2 glucometer'

product image
Glucometer

SD Check Gold 2 is a blood glucose self-monitoring device improved convenience from Gold model as it does not need a code chip for calibration. Advantage Fast and accurate results in 5 seconds No coding Wide pure gold electrode Specification Enzyme Glucose Oxidase biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Test Time 5 sec Sample Volume 0.9µl Hematocrit 20 - 60% Unit mg/dL Memory Up to 400 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC22 SD CHECK® GOLD 2 Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS20 SD CHECK® GOLD 2 Blood Glucose Test Strip SD CHECK® GOLD 2 Test Strip (25EA x 2 bottle)

Send Message
product image
Glucometer

SD CHECK GOLD is a blood glucose self-monitoring device has a code chip which contains information such as test strip expiration date to ensure that you do not receive an inaccurate result by using an expired test strip. Advantage Fast and accurate results in 5 seconds Simple code chip calibration Wide pure gold electrode Specification Enzyme Glucose Oxidase biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Test Time 5 sec Sample Volume 0.9 µl Hematocrit 20 - 60% Unit mg/dL Memory Up to 400 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC10 SD CHECK® GOLD Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS10 SD CHECK® GOLD Blood Glucose Monitoring System SD CHECK® GOLD Test Strip (25EA x 2 bottle)

Send Message
product image
Glucometer

GLUCOCARD G+ LINK glucometer You can stay safe about your health by bringing home this Blood Instant glucometer. It delivers accurate results, so you can constantly know what measure to take . It also comes with easy-edge test strips which can freely absorb the blood from your finger. Also, thanks to the WeCheck diabetes management app, it can send your test results to your smartphone. So now no need to give trouble to yourself by manually uploading your results in some third-party apps. Features: EASY WIRELESS SYNCHRONIZATION: Once connected with wecheck management app, results transfer instantly to the WeCheck Mobile App using Bluetooth technology AMAZINGLY ACCURATE: Highly accurate than other devices and provides proper results in some seconds. SHARE HEALTH DATA: You can share your health measurement data easily with your doctors and medical staff via WeCheck App. MOST AFFORDABLE ADVANCED DEVICE: You will get advanced technology with Bluetooth at a very cheaper rate. JAPANESE TECHNOLOGY, MANUFACTURED IN INDIA: Made in India & designed with trusted and advanced technology that ensure accurate results INDIVIDUALLY PACKED TEST STRIPS: Minimizes exposure to humidity, ensuring accurate results and longer shelf life of 18 months AUTO-CODING FUNCTION: Eliminates coding errors, ensuring easy, stress-free & accurate self-testing at home BEFORE & AFTER MEAL RESULT FLAGGING: Flags results as pre & post-meal reading, easy comparison reference for user & doctor RESULT LEVEL INDICATOR: Classifies results in various levels for easy interpretation TEST STRIP SAFE EJECT BUTTON: Safer and cleaner way to dispose of used strip without touching it About WeCheck App: Wecheck App offers many useful functions for diabetic patients, like Blood glucose level management, Insulin, Diet record, Pedometer and Vital Records Control. So you can connect Your device via Bluetooth and it starts recording your health data automatically. WeCheck has another good functionality to convert your records in pdf format, it makes it convenient to show your doctors while regular checkups. By managing data on the cloud You can prevent the loss of valuable data due to smartphone failure or model exchange and restore data smoothly. And You can also share data with family members, close people, and medical staff. Playstore Download Button: https://play.google.com/store/apps/details?id=jp.co.arkray.android.wecheck Apple Store Download Button: https://apps.apple.com/in/app/wecheck-diabetes/id1287838398

Send Message
product image
Glucometer

STANDARD CodeFree Plus SD Codefree plus is an easy and simple blood glucose monitor that intuitively tells the user if the blood glucose level is low, on target or high with LED light and beep sound. Advantage Intuitive notification of result with LED light and beep sound No coding SD CodeFree test strips can be shared with other devices Specification Enzyme Glucose Oxidase biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Test Time 5 sec Sample Volume 0.9 µl Hematocrit 20 - 60% Unit mg/dL Memory Up to 100 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC50 STANDARD™ CodeFree® Plus Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS50 STANDARD™ CodeFree® Plus Blood Glucose Test Strip STANDARD™ CodeFree® Plus Test Strip (25EA x 2 bottle)

Send Message
product image
Glucometer

STANDARD Mentor The pain associated with blood drawing has been minimized because it has been developed to measure accurately even with an amount of blood as minimal as 0.3 µl. About this item Approved Glucometer : FDA and KMFDS Approved, Accuracy Criteria : Its Fulfills EN ISO 15197 : 2015 International Standards. Minimum Blood Sample Needed : 0.3 μl, Memories : Standard Mentor Glucometer allows to save previous and up to 500 test Memories Box Included : Glucometer, 10 Lancets, 10 Strips, 1 Lancing Device, 1 Meter Check Strip, 3V Battery type CR2032, Carrying case, User Instruction Guide, Warranty Card. Pre & Post Meal Mark Alarm, No Coding Glucometer, 99.9% Gold Electrode Strip. Authorized Representative : MT Promedt Consulting GmbH - Altenhofstrasse 80 66386 St. Ingbert Germany. Warranty & Support : Standard Mentor Glucometer comes with Lifetime Warranty and support provided by Standard, For any product queries contact (18001023105). Advantage Minimized pain associated with blood drawing with an amount of blood as minimal as 0.3 µl No coding Accuracy that meets international standards

Send Message
product image
Glucometer

SD CodeFree A representative model of of SD BIOSENSOR which is easy to use and provides accurate results without the need for coding. The SD Codefree Blood Glucose Meter is a compact, hand-held, and easy-to-read monitor that stores up to 500 test results. It provides an accurate picture of your blood glucose level at the time of the test from a small droplet of blood. Specification Enzyme Glucose Oxidase biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Specimen volume 5 sec Sample Volume 0.9 µl Hematocrit 20 - 60% Unit mg/dL Memory Up to 500 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC110 SD CodeFree™ Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS11 SD CodeFree™ Blood Glucose Test Strip SD CodeFree™ Test Strip (25EA x 2 bottle)

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Glucometer Plus Kit Online, it’s a smart Glucometer Machine kit. This Digital Glucometer consists of 1 Blood Glucose Meter, 10 Test Strips, 1 Multilet Lancing Device, 10 Sterile Lancets, 1 Carry Pouch, 1 Warranty Card, Test Strip Insert Sheet, 1 Battery (3V) Gluco Plus Meter is intended for use in the home & in clinical settings. There are different types of Glucometers in Point of Care (POC). XPRESSGLUCO + meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). The system is intended for use outside the body (in vitro diagnostic use only). It should be used only for self-testing blood glucose (blood sugar) and only with fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh. The system is intended for use in the home and in clinical settings. The system should not be used for the diagnosis of diabetes or for the testing of newborns. Blood glucose is measured by an electrical current that is produced when a blood samples mixes with the reagent (special chemicals) of the test strip. The electrical current changes with the amount of glucose in the blood sample. The XPRESSGLUCO+ meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). Safety Information 1. The user should not take any decision of medical relevance without first consulting his or her medical practitioner. 2. Call your doctor immediately if you experience symptoms that are not consistent with your blood glucose test results. 3. High altitudes above than 3,402 meter (11,161 ft) may affect the test results. 4. Temperatures outside the range of 10°C to 40°C (50°F to 104°F) may affect the test results. Do not test beyond of temperature range. 5. Do not perform servicing and maintenance while the meter is in use. 6. No modification of this equipment is allowed. 7. Do not use this meter near cellular or cordless telephones in a call, walkie-talkies, garage door openers, radio transmitters, or other electrical or electronic equipment that are sources of electromagnetic, radiation, as these may interfere with the proper operation of the meter. Direction for Use 1. Wash you hands and puncture sit: Wash your hands in warm, soapy water. Rinse and dry completely . Warm your fingers to increase blood flow. 2. Insert Test Strip : Remove a new test strip from vial. Be sure to tightly replace vial cap after removing test strips. Insert a test strip with the contact bar end entering into the test strip slot first. Push the test strip as far as it will go without bending it. The meter turns on automatically. 3. Hold the prepared lancing device firmly against the side of your fingertip. Press the release button. (NOTE : If you want to do alternative site testing, please refer to the “About Alternative Site Testing (AST)” section. Please consult your healthcare professional before obtaining blood from site other than your fingertip.) 4. Obtain a Blood Sample : Gently massage your finger or puncture site to obtain the required blood volume. To perform the test, you need only 0.5 μL of blood sample. Do not smear the blood sample. To obtain best accurate result, wipe off the first drop of blood and gently squeeze another drop of blood. 5. Apply Blood Sample : When the meter shows the “ ” symbol, apply blood to the opening of the absorbent channel of the test strip where it meets the narrow channel. Blood will be drawn into the test strip. If the test strip confirmation window is full, you will hear a beep. 6. Read Your Result : After the meter counts down from 5 to 1, your blood glucose test result appears along with the unit of measure, date and time. Test result is lower than the target range Test result is within the target range. Test result is higher than the target range *The default target range is 70 mg/dl to 180 mg/dl. 7. Turn Off the Meter : This blood glucose result is automatically stored in the meter memory. Turn the meter off by removing the test strip. Discard the used test strip carefully to avoid contamination. 8. After use, twist off the Lancing Device Cap. Push the exposed tip of the lancet into its Protective Cap. 9. Slide the Lancet Ejector forward and disposing the used lancet in an approved container. Discard the used lancet according to your country’s safety regulations. Replace the Lancing Device Cap. Other Info •Use only XPRESSGLUCO+ Control Solution with your XPRESSGLUCO+ meter. •Check the expiration date on the bottle. Do not use if expired. •Use within a period of 90 days from the date that you first open it. Record the discard date on the control solution bottle when you first open it to serve as a reminder to discard after 90 days. •The control solution ranges are printed on the label of the XPRESSGLUCO+ Blood Glucose Test Strip vial. They are not recommended target ranges for your blood glucose. •For in vitro diagnostic use. •Do not add any liquid to the XPRESSGLUCO+ Control Solution. •Do not take internally or inject.

Send Message
product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Laboratory Usage

TACHOMETER/STROBOSCOPE, Model : BP-2259 ( 2 in 1, DIGITAL PHOTO TACHOMETER with DIGITAL STROBOSCOPE ) FEATURES* Intelligent, microprocessor circuit design, high accuracy, wide range, digital readout.* One instrument include two functions of " Digital Photo Tachometer " & " Digital Stroboscope "* Digital Stroboscope :Wide setting range from 100 RPM to 100,000 RPM, digital display with high accuracy. Modern solid state high visible orange light, long life, almost maintenance free. It is ideal for inspectingand measuring the speed of moving gears, fans, centrifuges, pumps, motors and other equipment used in general industrial maintenance, production, quality control, laboratories and as well as for schools and colleges for demonstrating strobe action.* Digital Photo Tachometer :No contact RPM measurement, wide measuring range from 0.5 to 100,000 RPM. 0.1 RPM resolution for the measured value < 1000 RPM. The last value, max., value, min. value can be stored into the memory automatically & be obtained by pressing " Memory Call Button ". High visible LCD display gives RPM reading exactly with no guessing or errors.* The use of durable, long lasting components, including a strong, light weight ABS plastic housing.Cabinet has been carefully shaped to fit comfortable in either hand. GENERAL SPECIFICATIONS Display 5 digits, 10 mm ( 0.4" ) LCD Operation 0 - 50 (32 - 122 ). ( Liquid Crystal display ) with Temperature function annunciation. Operating Less than 80% RH.Accuracy ± ( 0.1 % + 2 digit ). Humidity Sampling Time 1 second ( 60 RPM ). Size 215 x 65 x 38 mm.Time base:Quartz crystal. (8.5 x 2.6 x 1.5 inch). Circuit Exclusive one-chip design Weight 300g(0.66 LB)/including battery.microprocessor LSI circuit. Accessories : Carrying case ................... 1 PC.Battery 4 x 1.5V AA ( UM-3 ) battery. Operation manual ..............1 PC.ELECTRICAL SPECIFICATIONS ( PHOTO TACHOMETER )Measurement Range 5 to 99,999 RPM Resolution 0.1 RPM ( < 1,000 RPM ) 1 RPM ( 1,000 RPM )Photo Tach. detecting distance 50 to 150 mm/2 to 6 inch. * Typical max. 300 mm/12 inch depending upon ambient light.ELECTRICAL SPECIFICATIONS ( STROBOSCOPE )Stroboscopic 100 to 100,000 FPM/RPM Flash tube High efficiency orange LED Flash Rate FPM: flash per minute lamp.RPM : round per minute Flash Duration Approximately 60 to 1,000Flash Adjust 3 ranges : microseconds. Range Range A: 100-1,000 FPM Flash color Orange Range B: 1,000-10,000 FPM Flash Duration Approx. 16% of period time. Range C: 10,000-100,000 FPM Flash Adjust Coarse adjust knob and Resolution 0.1 FPM/RPM. Knob Fine adjust knob.(Less than 1,000 FPM/RPM) Calibration Crystal time base and1 FPM/RPM microprocessor circuit, don't(Over 1,000 FPM/RPM) necessary take any external calibration process. OPERATIONS PROCEDURES ( STROBOSCOPE )Preparation Determine the range switch to " 1000 RPM " ," 10,000 RPM " or" 100,000 RPM " position.Checking When checking speed, care must be taken to insure that the strobe is flashing in Speed unison (one to one) with the object being monitored. A Stroboscope will also stop motion at 2:1, 3:1, 4:1 et., this is normally referred to as harmonies. To be sure of unison, turn the dial until two images appear - this will double the actual speed. Then lower the flashing rate until a single and stationary image appears -this is the actual true speed.Checking For motion analysis, simply locate the actual speed as mentioned above and then Motion turn the dial slowly up or down. This will give a slow motion effect allowing complete inspection.

Send Message

Still searching for
sd check gold 2 glucometer?