Jaipur
+918529833535

'sample preparation'

Items tagged with 'sample preparation'

product image
Rapid Test

Intended Use Hepacard is visual, rapid, sensitive and accurate one step immunoassay for the qualitative detection of Hepatitis B surface antigen (HBsAg) in Human serum or plasma.The assay is intended to be used as an aid in the recognition and diagnosis of acute infections and chronic infectious carriers of the Hepatitis B Virus(HBV). Salient Features Detects all the 11 subtype of HBsAg. Antigen Sensitivity- 0.5 ng/ml. No sample preparation required. See through Device for easy result interpretation. Shelf life-30 months at 2-30°C. WHO Evaluated with 100% Sensitivity.

Send Message
product image
Rapid Test

The OnSite HSV-2 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 2 (HSV-2) in human serum, plasma or whole blood. Unique test that utilizes glycoprotein G2 to differentiate between HSV-1. and HSV-2 that allows for an early start of treatment action. Immediate determination of either acute or chronic infection by detecting and differentiating IgG and IgM anti-HSV-2. High confidence as test is in agreement with market leading European ELISA: 95.3% IgG; 100% IgM. Flexible specimen types including serum, plasma, or whole blood which allows testing at any time without special specimen preparation. Small sample volume (10 µL) enables multiple testing on the same specimen without having to re-draw the patient. Initial treatment action can begin during patient’s visit as test results are available in 10 minutes. Easily transported, and can be stored for 24 months, 2-30oC. Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0213, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance HSV-1 & HSV-2 Flyer Insert U.S. CDC HSV Homepage: Genital Herpes Fact Sheets WHO: Herpes Simplex Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite HSV-1 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) in human serum, plasma or whole blood. Type-specific detection by utilizing glycoprotein G1. Single test that detects and differentiates IgG and IgM anti-HSV-1. High confidence as test is in agreement with market leading ELISA test: 90.7% IgG; 85.0% IgM. Flexible specimen types including serum, plasma, or whole blood which allows testing at any time without special specimen preparation. Small sample volume (10 µL) enables multiple testing on the same specimen without having to re-draw the patient. Initial treatment action can begin during the patient’s visit as test results are available in 10 minutes. Easily transported, and can be stored for 24 months, 2-30oC. Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance HSV-1 & HSV-2 Flyer Insert U.S. CDC HSV Homepage: Genital Herpes Fact Sheets WHO: Herpes Simplex Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Typhoid IgG/IgM Combo Rapid Test is a lateral flow immunoassay for the detection and differentiation of IgG and IgM anti-Salmonella typhi (S. typhi) and paratyphi in human serum, plasma or whole blood. Utilizes O antigen and H antigen from both typhi and paratyphi serovars to maximize sensitivity Differentiates between IgG and IgM to determine stage of infection One step procedure minimizes operator error due to sample preparation Test result within 15 minutes allows medical professionals to take immediate action High level of reproducibility Test kits can be used and stored in a wide range of temperatures Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample Diluent (REF SB-R0161, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance Flyer Inserts U.S. CDC Typhoid Homepage: About Typhoid WHO: Health Topic for Typhoid

Send Message
product image
Rapid Test

The OnSite S. Typhi/Paratyphi Ag Rapid Test is a lateral flow chromatographic immunoassay for the simultaneous detection and differentiation of Salmonella typhi (S. typhi) and Salmonella paratyphi (S. paratyphi) antigens in a human fecal specimen and blood culture specimen. Detects the specific antigens from either S. typhi or S. paratyphi Earlier detection results in faster treatment for disease eradication Works with a variety of specimen types including: fecal, blood culture Simple procedure minimizes operator error due to sample preparation Test result within 15 minutes allows medical professionals to take immediate action High level of reproducibility Test kits can be used and stored at room temperature Individually sealed foil pouches containing: One cassette device One desiccant Stool collection devices, each containing 1 mL Fecal Sample Extraction Buffer (REF SB-R0162) Sample diluent (REF SB-R0162-2, 5 mL/bottle) Plastic droppers Patient ID stickers One package insert (instruction for use) CTK Products at a Glance Flyer Inserts U.S. CDC Typhoid Homepage: About Typhoid WHO: Health Topic for Typhoid CATALOG # PRODUCT QUANTITY SPECIMEN R0162C S. Typhi/Paratyphi Ag Rapid Test 25/kit Fecal, Blood Culture OTHER PRODUCTS YOU MIGHT BE INTERESTED IN… CATALOG # PRODUCT QUANTITY SPECIMEN R0161C Typhoid IgG/IgM Combo Rapid Test 30/kit S, P & WB

Send Message
product image
Urinalysis Analyzer

COBIO S50 is Fully Automated Urine Sediment Analyser. COBIO S50 is Automation of the "Gold Standard" manual microscopy! • Throughput - 50 sample/hours • Large (13.3') high-resolution touch-screen for viewing actual images • Each test is processed in 1 cuvette - no carry-over between samples • Just 1.5 mins testing time / sample • High-definition in-built cameras capture "whole view-field" images similar to HPF images of manual microscopy • Latest "deep learning AI" technology identify, classify, label and count each sediment particle - Fully automated sample preparation (sample mixing, centrifuging, preparation of homogenized layer) to minimize manual errors - Large touch-screen helps zoom-in / zoom-out to access and review images and easily access the menu. - Each test is processed in 1 cuvette – no carry-over between samples - Just 1.5 mins testing time / sample

Send Message
product image
Hemoglobin Meter

Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Operation Principle: The test strip utilizes Dry Chemistry Colorimeter Method (Azido methaemoglobin Method). When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors avtomatically measure the change in membrane reflectance. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Blood Sample Collection: Fresh or EDTA-anticoagulated capillary or venous whole blood may be used. If an EDTA – treated sample is refrigeratted to come to the room temperature before testing. EDTA treated blood samples should be mixed using end to and inversions at least 8 times prior to use, and should be tested within 24nours Do not use the haemolytic sample anticogulants other than EDTA are not recommended for use. Caution: 1. Same as all diagnostic tests, hemoglobin test results should be evaluated with the specific patient’s condition. Any results demonstrating the inconsistency with the patient’s clinical status should be repeated or supplemented with additional test data. 2. Do not touch the test membrane by hand 3. H12 Hemoglobin Test Strips are one-off product, do not use again Storage & Preparation: 1.H12 Hemoglobin Test Strips should be stored at O C-30 C dry and dark places, 2 C – B C is the best storage environment emperatures recommended. Keep away from direct sunlight and heat, must not be frozen, If the container was stored in refrigerated before first use, please don’t take it back into the refrigerator again after first use. 2. H12 Hemoglobin Test Strips are ready to use. No additional preparation is required 3. Enclosed desiccants with lest strip. Remove only those strips needed for testing. The remaining lest strips should be resealed in their onginal container and used up in 3 months after first use. Do not use lest strips and throw away alter expiry date. 4. Use the strip immediately once taking it out af the container, otherwise the result will be incorrect 5. Do not fold or cut the test strip. 6. Used lest strips cannot be used again, dispose them as normal medical waste Direction for Use Operating Instructions: 1. URIT Hemoglobin Meter, H12 Hemoglobin Test Strip, Lancing Device, and disposable blood taking needle. 2. Test steps: 1) Turn the meter on and input the Code Card. Check the Code Card displaying on the meter to ensure it to match the Code Card printed on the lest strip container. Otherwise, the result is incorrect. 2) Massage the patient’s finger from the knuckle up to the tip to stimulate blood flow. Clean the sample area with alcohol and wipe it dry with a sterile gauze pad. 3) Insert the lest strip into the strip holder with the notched end in first and the hole facing up. 4) Puncture the skin on the lower side of fingertip with blood collection needle, and remove 13-15 TIL of whole biood with capillary or other micro blood collection apparatus. While waiting for the instrument to display the blood drop symbol, quickly add the drops to the test hole on the reagent sheet. Please make sure that the blood drop volume can completely cover the test hole but not overflow the test hole. 5) The meter starts the test automatically after the blood sample disperses Once the lest is in process do nol disturb or move the meter or test strip, or press any key. The test result will display within 12 seconds. Qualtiy Control Procedure: Use only H12 Hemoglobin Test Strip with QC substance to perform QC. The range of QC substance is the numerical range indicated on the label of the QCsubstance or test strips. When to do a QCtest: 1. Whenever you suspect that the meter or test strips are not working properly. 2. If your hemoglobin test results are not consistent with how you feel. Other Info Limitations of test Method: H12 Hemoglobin Test Strip is only suitable for testing fresh or whole capillary blood or whole venous blood containing EDTA anticoagulants. Do not use serum, plasma or arterial blood

Send Message
product image
Hemostasis Analyzer

Product Description: It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting testCuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests. Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centres It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc Key Specifications: Single channel semi-automated hemostasis system It can analyze 1 test at a time Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 216 x 205 x 75 mm Weight : ~1 kg Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored Results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 1000 results for QC determinations Up to 1000 results for patients New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pen drive. Regular backup and file purging is recommended from the USB pen drive to insure rapid operations. USB pen drive, FAT32 formatted

Send Message
product image
Hemostasis Analyzer

Product Description: It’s an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S performed using Light scatter principle. Protein C, Antithrombin III done by Chromogenic Principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting test Cuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 412 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centers It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc General Specifications: 4 channel semi-automated hemostasis instrument It can perform 4 simultaneous tests of the same parameter Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second row of assay preparation/incubation during the analysis of the current line, using preparation line option It can run assays in single or duplicate (programmable per assay) Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Chromogenic (colorimetry at 405nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 300 x 290 x 90 mm Weight : 3 kgs Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply: 100-240 VAC and 50/60 Hz Power Consumption: 45 Watts In-Rush Power: 150VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control names total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 600 results for QC determinations (run in duplicate) Up to 900 results for patients (run in duplicate) New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pendrive. Regular backup and file purging is recommended from the USB pendrive to insure rapid operations. (We recommend at least a monthly purge from a computer to back up and remove CH files) USB pendrive , FAT32 formatted

Send Message

Still searching for
sample preparation?