Jaipur
+918529833535

'salmonella typhi bacteria'

Items tagged with 'salmonella typhi bacteria'

product image
Rapid Test

Intended Use Advantage Typhi IgM & IgG Card is a rapid solid phase immuno-chromatographic test for the qualitative differential and simultaneous detection of salmonella typhi (S. typhi) IgM and IgG antibodies in human serum / plasma. This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of typhoid infection and in the determination of recent and past infection. Salient Features Rapid qualitative test for differential detection of Salmonella typhi (S.typhi) IgM and IgG Antibodies in Human Serum / Plasma Determination of both recent and past infection Results within 20 minutes Bio-hazard free, fully covered, see-through Device Simple & Easy to use Test Procedure No Instruments required Long Shelf Life: 30 months at 2-30ºC Convenient Pack size: 50 Tests

Send Message
product image
Rapid Test

The OnSite S. Typhi/Paratyphi Ag Rapid Test is a lateral flow chromatographic immunoassay for the simultaneous detection and differentiation of Salmonella typhi (S. typhi) and Salmonella paratyphi (S. paratyphi) antigens in a human fecal specimen and blood culture specimen. Detects the specific antigens from either S. typhi or S. paratyphi Earlier detection results in faster treatment for disease eradication Works with a variety of specimen types including: fecal, blood culture Simple procedure minimizes operator error due to sample preparation Test result within 15 minutes allows medical professionals to take immediate action High level of reproducibility Test kits can be used and stored at room temperature Individually sealed foil pouches containing: One cassette device One desiccant Stool collection devices, each containing 1 mL Fecal Sample Extraction Buffer (REF SB-R0162) Sample diluent (REF SB-R0162-2, 5 mL/bottle) Plastic droppers Patient ID stickers One package insert (instruction for use) CTK Products at a Glance Flyer Inserts U.S. CDC Typhoid Homepage: About Typhoid WHO: Health Topic for Typhoid CATALOG # PRODUCT QUANTITY SPECIMEN R0162C S. Typhi/Paratyphi Ag Rapid Test 25/kit Fecal, Blood Culture OTHER PRODUCTS YOU MIGHT BE INTERESTED IN… CATALOG # PRODUCT QUANTITY SPECIMEN R0161C Typhoid IgG/IgM Combo Rapid Test 30/kit S, P & WB

Send Message
product image
Rapid Test

Buy AccuTest Typhoid IgG/IgM Rapid Card Test (5 Tests) Online from Accurex. The Typhoid IgG/IgM Rapid Test is used for detection & differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood / serum / plasma. This Typhoid test is used as a screening test and as an aid in the diagnosis of infection with S. typhi. Salmonella typhi bacteria causes typhoid Typhoid fever, typhoid symptoms symptoms are likely to develop gradually – appearing one to three weeks after exposure to the disease. There are various typhoid treatment & typhoid vaccine which can be opted after the detetction of Typhoid. Typhoid fever is caused by S. typhi, a Gram-negative bacterium. Worldwide an estimated 17 million cases and 600,000 associated deaths occur annually. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi. Evidence of H. pylori infection also presents an increased risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gall bladder. The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test. In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen thus to aid in the determination of current or previous exposure to the S. typhi. PRINCIPLE The Typhoid IgG/IgM Rapid Test is a lateral flow immunochromatographic assay. The test cassette consists of: 1) a pink-purple colored conjugate pad containing recombinant S. typhi H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test region (Test line M and G) and a control region (control line). The test line ‘M’ is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, test line ‘G’ is pre-coated with monoclonal anti-human IgG for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody at test region ‘M’, forming a pink-purple line at ‘M’ region, indicating a S. typhi IgM positive test result. Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a pink-purple line at test region ‘G’, indicating a S. typhi IgG positive test result. Absence of any pink-purple line at test region (M and G) suggests a negative result. The test contains an internal control (control line) which should exhibit a pink-purple line of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test region. Otherwise, the test result is invalid and the specimen must be retested with another device. PRECAUTION 1. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results. 2. Do not open the sealed pouch, unless ready to conduct the assay. 3. Do not use expired devices. 4. Bring all reagents to room temperature (15°C-30°C) before use. 5. Do not use the components in any other type of test kit as a substitute for the components in this kit. 6. Do not use hemolized blood specimen for testing. Wear protective clothing and disposable gloves while handling the kit reagents and clinical specimens. Wash hands thoroughly after performing the test. 7. Users of this test should follow the US CDC Universal Precautions for prevention of transmission of HIV, HBV and other blood-borne pathogens. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents are being handled. 9. Dispose of all specimens and materials used to perform the test as biohazardous waste. 10. Handle the Negative and Positive Control in the same manner as patient specimens. 11. The testing results should be read within 15 minutes after a specimen is applied to the sample well or sample pad of the device. Read result after 15 minutes may give erroneous results. 12. Do not perform the test in a room with strong air flow, ie. an electric fan or strong air-conditioning. Other Info STORAGE AND STABILITY Typhoid IgG/IgM test card should be stored at 4-40°C. The card may be stored at room temperature but not exceeding 40°C in the original sealed pouch. The shelf life or expiry of the card is printed on Pouch as well as carton label. The test kit should be kept away from direct sunlight, moisture and heat.

Send Message
product image
Rapid Test

The OnSite Typhoid IgG/IgM Combo Rapid Test is a lateral flow immunoassay for the detection and differentiation of IgG and IgM anti-Salmonella typhi (S. typhi) and paratyphi in human serum, plasma or whole blood. Utilizes O antigen and H antigen from both typhi and paratyphi serovars to maximize sensitivity Differentiates between IgG and IgM to determine stage of infection One step procedure minimizes operator error due to sample preparation Test result within 15 minutes allows medical professionals to take immediate action High level of reproducibility Test kits can be used and stored in a wide range of temperatures Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample Diluent (REF SB-R0161, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance Flyer Inserts U.S. CDC Typhoid Homepage: About Typhoid WHO: Health Topic for Typhoid

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ PCT Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Procalcitonin (PCT) in human whole blood, serum or plasma. This test is used as an aid to diagnosis severe, bacterial infection and sepsis. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ CRP/PCT Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of C-Reactive Protein (CRP) and Procalcitonin (PCT) in human whole blood, serum or plasma. This test is used as an aid to see infection and inflammation and used to aid in the early detection of clinically relevant bacterial infections. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Clinical Chemistry

HyPort B30 With the higher requirement of the healthcare, and continuing focus on the efficient clinical workflow, the advanced medical technology is always demanded from the patients and hospital. While some hospitals have limited space and budget, they search for a simple pendant solution to enhance the work efficiency and better care for the patient. Mindray HyPort B30 provides a simple, compact and cost-effective design for Anesthesia Pendant and Surgical Pendant in OR and ICU Pendant to meet this requirement. Less space needed with slimmer column design Easy to handle for nurse after reducing pendant weight Hygienic surface with anti-bacteria coating Built-in rails for accessories and no exposed screws

Send Message
product image
Immunology Analyzer

KRYPTOR COMPACT PLUS KEY FACTS The KRYPTOR compact PLUS is a fully automated Random Access Immuno Analyzer. Able to process a multitude of samples and tests per day. Closed system. It is based on the Noble prize winning TRACE (Time Resolved Amplified Cryptate Emission) technology. Throughput is up to 60 tests per hour. Precise measurement. Eco friendly as there are less liquid wastes. Intelligent dilution i.e., out-of-range samples are detected within 5 minutes and immediately diluted. Quick turnaround time. Low sample volume- 10 µl to 70 µl (test specific) Assays that can be performed Categories: Biomarker, Fully Automated Immunoassay Analyzer, Fully Automated Immunoassay Analyzer instruments Prenatal screening for 1st trimester PAPP-A Free bhCG Instruments, reagents and software, are all FMF certified! Procalcitonin for bacterial sepsis Chromagranin A for Neuroendocrine Tumors (NET) Pre-eclampsia screening and diagnosis PAPP-A and PlGF for screening sFlt-1/PlGF ratio for diagnosis Cardiac marker- Copeptin proAVP To rule our acute myocardial infarction Direct testing of diabetes insipidus

Send Message

Still searching for
salmonella typhi bacteria?