product image
Digital Spectrophotometer

Product Details: Application Laboratory Accuracy 0.001 g Position Hand Held Make Japan, Brix Material Steel, Rubber Type Portable We are the leading of Coolant Hand Refractometers. Salinity Refractometer, ERMA, Japan Make, Range: 0-28%, Range: 0-100% Hand Refractometer Model D, for urine, Serum / Protein, ERMA JAPAN make Model : D Refractometer for battery/ coolants, ERMA Japan Gem Refractometer Digital portable refractometer imported Make Brix : 0-45%, Refractive Index Range : 1.3330 to 1.7000 Digital portable refractometer imported Make Brix : 0-95%, Refractive Index Range : 1.4098 to 1.5318 nD, Salinity : 0-30% U.S.A Salinity meter, Digital (Table Model), 3 1/2 Digit LED Display with Salinity Cell & Other Accessories Digital specific gravity salinity meter Temperature Meter, Model DSG - 10 Range : Specific Gravity : 1.000 - 1.030, Salinity (PPT) : 5 ppt to 40 ppt, Temp : 0ºC - 100ºC Digital salinity TDS Temperature Meter, Model: HDS 1024, Imported Make Range : Salinity : 0.00 - 5.00 % Salt, TDS : 0-999 ppm mg/L, Temperature : 0ºC to 100ºC

Send Message
product image
Digital Spectrophotometer

Product Details: Minimum Scale Salinity 1% Specific gravity 0.001 Scale range Salinity 0.0 to 100.0% Specific gravity 1.000 to 1.070 Weight 200g Length 4 cm Width 4 cm Height 21 cm Description: The S/Mill-E density meter measures the salinity and the specific gravity of sea water. The salinity of sea water is displayed in parts per mill (%) unit. The ATC-S/Mill-E model is designed with the Automatic Temperature compensation feature which automatically provides the measurement values at the compensated temperature of 20°C (compensation range 10 30°C). Specifications: Scale range Salinity 0.0 to 100.0% Specific gravity 1.000 to 1.070 Minimum Scale Salinity 1% Specific gravity 0.001 Size and weight 4X4X21 cm, 200 g

Send Message
product image
Laboratory Usage

We are the Leading Supplier of Abbe Refractometer Rajdhani. In the Abbe'' refractometer the liquid sample is sandwiched into a thin layer between an illuminating prism and a refracting prism. The refracting prism is made of a glass with a high refractive index (e.g., 1.75) and the refractometer is designed to be used with samples having a refractive index smaller than that of the refracting prism. A light source is projected through the illuminating prism, the bottom surface of which is ground (i.e., roughened like a ground-glass joint), so each point on this surface can be thought of as generating light rays traveling in all directions. A detector placed on the back side of the refracting prism would show a light and a dark region. Over a century after Abbe''s work, the usefulness and precision of refractometers has improved, although their principle of operation has changed very little. They are also possibly the easiest device to use for measuring the refractive index of solid samples, such as glass, plastics, and polymer films. Some modern Abbe refractometers use a digital display for measurement, eliminating the need for discerning between small graduations. However, the user still has to adjust the view to get a final reading. The first truly digital laboratory refractometers began appearing in the late 1970s and early 1980s, and no longer depended on the user''s eye to determine the reading. They still required the use of circulating water baths to control instrument and fluid temperature. They did, however, have the ability to electronically compensate for the temperature differences of many fluids where there is a known concentration-to-refractive-index conversion. Most digital laboratory refractometers, while much more accurate and versatile than their analog Abbe counterparts, are incapable of readings on solid samples. In the late 1990s, Abbe refractometers became available with the capability of measurements at wavelengths other than the standard 589 nanometers. These instruments use special filters to reach the desired wavelength, and can extend measurements well into the near infrared (though a special viewer is required to see the infrared rays). Multi-wavelength Abbe refractometers can be used to easily determine a sample''s Abbe number.

Send Message
product image
Laboratory Usage

Aided by a team of qualified and expert designers, we are involved in offering a wide gamut of Refractometer Manual. The offered product is appreciated among customers owing to its fine finish & optimum quality. This product is manufactured by our workforce utilizing excellent quality material and sophisticated techniques in accordance with the set quality standards. Our given product is accessible in assorted specifications as per the definite requirements of the customers. Features: Precisely designed Accurate testing Reliability ABBE Refractometers: Model NAR-1T LIQUID Range 1.3000 to 1.7000 with sugar scale 0-95% built in light fourth place by estimation 5 to 50ºC temperature Model NAR-2T for high temperature samples from 0 to 120ºC temperature Model NAR-3T for precision measurement of the fourth place 5-50ºC temperature Model NAR-4T for high refractive index measurement range 1.4700 to 1.8700 Abbe Refractometer Manual Model 2WAJ - R I- nD 1.3000 to 1.7000 & Sugar percentage (Brix) Product Details: Model 2WAJ-RI Application Industrial, Laboratory Display Digital Operation Manual Range 0-95%

Send Message
product image
Laboratory Usage

We are the Leading Supplier of Hand Sugar Refractometer. Hand Sugar Refractometer is developed for working with sugar related liquids (fruit juice, soft-drinks, wine, honey), help monitor to control sugar concentrations in foods and beverages. Checking the “ripeness” of fruit in the field, verifying product quality after harvesting or controlling concentrations during processing and packaging, refractometers provide critical information to ensure product quality. And the model RHB-10, RHB-18 and RHB-32 are also commonly used for controlling the concentration of various industrial fluids (cutting lubricants and flux rinsing compounds). Model Range Min.Div. Accuracy Remark RHB-10 Brix: 0-10% Brix: 0.1% Brix: ±0.10% ATC RHB-18 Brix: 0-18% Brix: 0.1% Brix: ±0.10% ATC RHB-32 Brix: 0-32% Brix: 0.2% Brix: ±0.20% ATC RHB-55 Brix: 0-55% ATC RHB-62 Brix: 28-62% Brix: 0.2% Brix: ±0.20% ATC RHB-82 Brix: 45-82% Brix: 0.5% Brix: ±0.50% ATC Brix: 58-92% Brix: 0.5% Brix: ±0.50% RHB-92 Baume: 38-43Be' Baume: 0.5Be' Baume: ±0.50Be' ATC water: 12-27% water: 1% water: ±1%

Send Message
product image
Laboratory Usage

Keeping the diverse requirements of customers in mind, we are instrumental in providing Abbe Refractometer Manual GNI. Our Offered products are made in accordance to the set industry parameters. Other Details: ABBE Refractometer Refractive Index nD 1.3000 to 1.7000 & Sugar percentage (Brix) ABBE Refractometer RL-3 POLAND Make ABBE Refractometer 2 WAJ TAIWAN Make (Imported) ABBE Refractometer RAJDHANI Model No.RSR - 1 Make INDIAN ABBE Refractometer ADVANCE Model R-4 INDIAN ABBE Refractometer GNI or Other Make Best Quality with Warranty INDIAN Product Details: Model NAR-1T ATAGO Application Industrial Temperature Range 5-50 deg C Range 0-95% Operation Manual Packaging Type Carton