Jaipur
+918529833535

'safe handling'

Items tagged with 'safe handling'

product image
Glucometer

Item Description The Accu-Chek Safe-T-Pro Uno lancing device keeps up with increased safety and hygienic requirements by health authorities, legislators, and health institutions. At the same time, it provides an ergonomic handling, lancing in just 3 milliseconds, and safety features that prevent accidental needle sticks. Its pre-set lancing depth makes it ready to use immediately. Benefits and Features Ready to use with a pre-set depth setting Safe-T-Technology ensures the needle is always safely stored away Stored needle prevents accidental needle sticks Ergonomical and easy to grip for safe handling Hygienic - each lancet can only be used once Beveled needle and small diameter for virtually pain-free blood sampling Equally suitable for right and left-handed use After a single use, the complete lancing device is disposed of Additional specifications Pre-fixed depth setting: Yes Penetration depth: 1.5 mm Needle diameter : 0.36 mm (28 G) Special needle cut: 3-facet cut Siliconized needle: Yes Sterility : 4 years after sterilization Single-use only: Yes Automatic retraction of needle : Yes Recognition of used device : Yes Intuitive handling : Yes How to use the Accu-Chek Safe-T-Pro Uno Simple, 2-step lancing Twist the sterility cap one quarter turn and remove it. Hold the lancing device between your index finger, middle finger, and thumb. Press the lancing device firmly against the chosen puncture site. Using your thumb, press the release button down completely. Move the lancing device away from the puncture site and discard it.

Send Message
product image
Glucometer

Accu-Chek® Active blood glucose meter Personalised Diabetes Coaching Accurate, no coding, easy Item Description The Accu-Chek Active blood glucose meter packs many powerful features into a smaller size. No coding reduces handling steps, see test result averages up to 90 days, get alerts if your test strips are expired or if you’ve underdosed, re-dose within 10 seconds, set pre-and post-meal reminders to test, and more. Benefits and Features accurate: Accurate1 blood glucose measurement easy: No coding for even easier blood glucose monitoring easy-to-read display (new typeface) intuitive handling with just 2 buttons safe: Underdose detection visual double check 10 seconds re-dose option clever: Pre- and postmeal markers postprandial reminder 7,14,30 or now 90 day test averages USB interface for data transfer Remark: Previous Accu-Chek Active meter generations will be upgraded to no coding via black activation chip . Know more>> 1The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). Additional specifications Meter type : Accu-Chek Active meter (Model GB) Catalogue no. / Serial no. : See type plate on the back of the meter Test principle : Determination of glucose in fresh capillary blood by reflectance photometry. Blood glucose values can be tested in whole blood or plasma. The meter displays blood glucose values corresponding to those in plasma. Measuring interval : 10-600 mg/dL Blood volume : 1-2 μl Measuring time : Test strip in the meter: approx. 5 seconds Test strip outside the meter: approx. 08 seconds Power supply : 1 battery (type CR2032) Battery life : approx. 1000 tests or approx. 1 year Automatic power-off : after 30 or 90 seconds depending on operating status Memory : 500 test results with time and date, as well as 7, 14, 30 and 90 days averages Temperature : During testing: +8 to +42°C During storage without battery: -25 to +70°C During storage with battery: -20 to +50°C Atmospheric humidity : During testing: up to 85% relative humidity During testing: up to 93% relative humidity Altitude: Sea level to 4000 m Dimensions : 97.8 x 46.8 x 19.1 mm Weight : Without battery: approx. 46 g With battery: approx. 50 g Display : 96-segment liquid crystal display (LCD) Interface : USB (Micro B) Safety class : III Electromagnetic compatibility : The Accu-Chek Active meter meets the electromagnetic immunity requirements and the electromagnetic emissions requirements as per EN 61326-2-6 and EN ISO 15197 Annex A. The chosen basis for electrostatic discharge immunity testing was basic standard IEC 61000-4-2. Performance analysis : Calibration and traceability: The performance data for the Accu-Chek Active bGM system was calibrated using venous blood containing various glucose concentrations. Reference values are obtained using the hexokinase method, which is calibrated using the ID-GCMS method. Accuracy performance : The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). How to use Accu-Chek Active blood glucose meter Testing your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in 4 simple steps. Insert the glucose test strip Prick your finger with the lancet to draw out a blood drop. Carefully touch the blood drop onto the green field of the test strip. Read the blood glucose result.

Send Message
product image
Rapid Test

Buy Dengue NS1 Antigen test (Pack of 5 test) from Accurex. This NS1 Antigen Rapid test contains: A Test device in aluminum pouch with a desiccant, Disposable dropper & Pack Insert. Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. Dengue NS1 Antigen kit is for professional use and only for the initial screening test & reactive samples should be confirmed by a supplemental assay such as nucleic acid test & other immunological assays. EXPLANATION OF THE TEST Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre-coated anti-dengue NS1 monoclonal antibody on the test band region (T), and goat anti-mouse IgG is pre-coated on the control band region (C). During testing, if the sample containing dengue NS1 Ag, the complex of the antibody-dengueNS1 Ag-gold conjugate moves laterally on the membrane by capillary action. In this case, the colored band will appear on the membrane in test line (T). Control line (C) should always appear if the test procedure is performed properly Safety Information 1. For in-vitro diagnostic use only. Do not re-use the test device. 2. The instruction must be followed exactly to get accurate results. 3. Anyone performing an assay with this product must be trained in its use and must be experienced in laboratory procedures. 4. Do not eat or smoke while handling specimens. 5. Wear protective gloves while handling specimens. Wash hands thoroughly afterwards. 6. Avoid splashing or aerosol formation. 7. Clean up spills thoroughly using an appropriate disinfectant. 8. Decontaminate and dispose of all specimens, reaction waste, in a biohazard container. 9. Do not mix and interchange different specimen. 10. The presence of humidity may decrease the stability of the tests. Thus, carry out the test immediately after removing the device from the foil pouch. 11. Do not use it beyond the expiration date. Direction for Use 1. Place all specimens, test device and solution. Allow them to room temperature prior to testing (15~30 min.) 2. Please perform the test immediately after removing the device from the foil pouch. 3. With a disposable dropper, load 2-3 drops (50 to 75µl) of specimen into the sample well (S) in the test device. 4. Interpret the test results between 15~20 minutes. Do not read the results after 20 minutes. Other Info 1) Dengue NS1 Antigen test should be stored between 4~30 ºC 2) Expiration date of this kit is 24 months after its manufacture date. LIMITATIONS OF THE TEST Dengue NS1 antigen test is designed for primary screening test of dengue virus NS1 antigen. Although this can provide fast and easy way to get a result, the testing do not completely exclude the possibility of false positive or negative result caused by various factor. So, refer to the result of the kit, please make a final decision with clinical manifestation, other test results and doctor’s view collectively.

Send Message
product image
Rapid Test

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 10 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % Safety Information Important saftey handling: • Wash hands thoroughly, with soap and water before and after testing • Never use fingerstick devices for more than one person. Use auto disabling, single use fingerstick devices for assisted monitoring of blood glucose. Storage & Handling: • Store the strips in their original vial in a cool, dry place between: 0°-50° C (32° and 122° F). Keep away from direct sunlight and heat. • Do not refrigerate or freeze. • When you take a strip from the vial, close the cap immediately. Use the strip immediately. • Check the expiry date on the vial. If the expiry date has passed, do not use the strips. Important health-related information: • Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult your physician or doctor immediately. • Test results below 70 mg/dL. mean low blood glucose (hypoglycemia). • Test results greater than 180 mg/dL mean high blood glucose (hyperglycemia). • If you get results below 70 mg/dL or above 180 mg/dL and do not have symptoms of hypoglycemia or hyperglycemia, repeat the test. If you have symptoms or continue to get results that fall below 70 mg/dL or above 180 mg/dL, follow the treatment/advice of your healthcare professional. • If you are experiencing symptoms that are not consistent with your blood glucose test and you have followed all instructions described in the Xpress Gluco owner’s booklet, consult your healthcare professional Other Info UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Hematology

Buy the Best 5 Parts Hematology Analyzer – ACCULAB CBC 560+. This Hematology Analyser Machine is an advanced and automatic hematology analyzer, comprising 5 parts, 29 parameters, and 3 histograms assay, offers throughput of 60 tests/hour. Features: Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting and Cyanide-free method for HGB test along with 3D holographic scattergram to display the accurate 5 part differentiation of WBC. Equipped with a 14 inch touch screen and large storage capacity for 100,000 results, this hematology analyzer has interface of 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader. With CBC mode, CBC+DIFF mode, Venous whole blood, Capillary whole blood and Prediluted test mode, this hematology analyzer is an ideal unit for white blood cell counts, complete blood Measuring principle Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test Sample volumes CBC+DIFF mode: ≤ 20 μl CBC mode: ≤ 10 μl Throughput 60 tests/hour Assay Items 29 parameters, 3 histograms Display 14 inch touch screen Storage 100,000 sample results, including histograms, scattergrams and patient information Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT,PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%,BAS%,NEU#, LYM#, MON#, EOS#, BAS# 4 Research parameter: ALY%, ALY#, LIC%, LIC# Performance Item Linearity range Carry Over CV WBC 0-300 × 109/L ≤ 0.5% ≤ 2.0 % RBC 0-8.00 ×1012/L ≤ 0.5% ≤ 1.5 % HGB 0-250 g/L ≤ 0.5% ≤ 1.5 % PLT 0-3000 × 109/L ≤ 1.0% ≤ 4.0 % Interface 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader Power Consumption 400 VA Power Supply AC 220V±10%, 50/60Hz, 110V±10%, 60Hz Packaging dimension (W×D×H) 670 × 590 × 790 mm Gross Weight 53 kg Safety Information All the samples, controls, calibrators, reagents, waste and areas contacted with them are potentially biohazardous. Wear proper personal protective equipment (e.g. gloves, lab coat, etc.) and follow safe laboratory procedures when handling them in the laboratory.

Send Message
product image
Glucometer

afe AQ Angel FAD-GDH Monitoring System & Strong anti-interference Accurately & Professional & Battery Power Warning A study evaluating glucose values from fingertip capillary blood samples obtained by 100 lay persons showed the following results: 100 % within ±0,83 mmol/L (±15 mg/ dL) of the YSI values at glucose concentrations below 5,55 mmol/l (100 mg/ dL), and 100 % within ±15 % of the YSI values at glucose concentrations at or above 5,55 mmol/L (100 mg/ dL). Overview Safe AQ Angel Blood Glucose Monitoring System is designed for easy, user-friendly, convenient operation and only needs a small volume of blood sample. The Safe AQ Angel Test Strips require no coding which saves time and avoids human error due to improper operations. The memory mode allows you to save up to 200 blood glucose test results and 10 blood glucose control solution test results. Features (Technical advantages) 1) Anti multiple interferences reliable results 2) Less blood volume required only 0.6μL 3) User-friendly operation system: fast 5s test time & non-interference Performance Characteristics The Safe AQ Angel blood glucose monitoring system complies with the requirements of ISO 15197:2013 ( In vitro diagnostic test systems- Requirements for blood glucose monitoring systems for self-testing.

Send Message
product image
Glucometer

Sinocare Blood Glucose Uric Acid Strips[Safe AQ UG] Pay attention to your body uric acid index. Fight Gout and Win💪 The validity period of blood glucose test strip is 24 months. Please use it within 6 months after opening the bottle. The validity period of uric acid test strip is 15 months. Please use it within 3 months. Warm Tips : Affected moderately by the environment humidity, the measured value will fluctuate by 15%, which is normal. Please try to store the test strips in an environment with moisture <80% to improve accuracy. Remove a new test strip within the valid expiration of the vial. After taking the strip, immediately cover the vial to avoid losing efficiency. Insert the test strip into the strip slot; the test strip is suggested to use in 3 minutes. Write the discard date (6 months after opening the vial) on the vial label when you open it for the first time. Discard the remaining test strips after the discard date. The test strips are for individual use only. Never reuse a test strip that has applied blood. Please don't store this blood glucose kit where it's too hot or cold. Keeping your fingers clean, wipe the first drop of blood away with a clean tissue, and test with the second drop of blood, which is less likely to be contaminated when using the testing kit. Adjust the depth of your lancing device according to your skin thickness when testing blood sugar.

Send Message
product image
Glucometer

Sinocare Blood Glucose Uric Acid Meter with Advanced Test Strips Lancet Safe AQ UG for Multifunctions (82) Pay attention to your body uric acid index. Fight Gout and Win💪 Note: The validity period of blood glucose test strip is 24 months. Please use it within 6 months after opening the bottle. The validity period of uric acid test strip is 15 months. Please use it within 3 months. Warm Tips : Affected moderately by the environment humidity, the measured value will fluctuate by 15%, which is normal. Please try to store the test strips in an environment with moisture <80% to improve accuracy. Remove a new test strip within the valid expiration of the vial. After taking the strip, immediately cover the vial to avoid losing efficiency. Insert the test strip into the strip slot; the test strip is suggested to use in 3 minutes. Write the discard date (6 months after opening the vial) on the vial label when you open it for the first time. Discard the remaining test strips after the discard date. The test strips are for individual use only. Never reuse a test strip that has applied blood. Please don't store this blood glucose kit where it's too hot or cold. Keeping your fingers clean, wipe the first drop of blood away with a clean tissue, and test with the second drop of blood, which is less likely to be contaminated when using the testing kit. Adjust the depth of your lancing device according to your skin thickness when testing blood sugar.

Send Message
product image
Glucometer

ityhealth Sinocare Safe Accu 25 Blood Glucose Test Strips || 25 Glucometer Strips nformation about RGB Sinocare Safe-Accu Blood Glucose Test Strip (25 Each) RGB Sinocare Safe-Accu Blood Glucose Test Strips are used to measure blood glucose concentration. It can be self-tested for home and professional usage. It is easy to use and handle. Uses: It helps to check one's blood glucose levels using a glucometer Product Specifications and Features: It is convenient to use as a tiny blood sample is required The box contains 50 disposable strips It ensures hygienic and fast blood absorption It helps to observe blood sugar levels It provides accurate results within a few seconds Directions For Use: Use as directed on the label Safety Information: Store in a dry and hygienic place Read the label before use Keep out of reach of small children.

Send Message

Still searching for
safe handling?