Jaipur
+918529833535

'rs 232 c serial interface dimensions'

Items tagged with 'rs 232 c serial interface dimensions'

product image
Clinical Chemistry

Product Description: XL-640 with CRS is a random access, discrete, patient prioritized, fully automated clinical chemistry analyzer with autoloader designed to meet the needs of today’s modern clinical laboratories with high workload. Once samples are loaded, it is a complete walk-away system. XL 640 CRS is designed to operate smoothly over the long haul and to deliver consistent quality report. Product Features: Throughput of 400 tests/ hour (Photometric) and 640 tests/hour with ISE 56 Reagent Positions with On-board cooling for reagents 162 Sample positions with /Autoloader Separate probes for reagent R1 & R2 and dedicated probe for sample Clot detection for sample probe, Reflex testing and Serum Indices identification 72 permanent hard glass cuvettes with On-board Laundry Automatic dilution for high abnormal samples & Auto Rerun facility Extensive QC Programmes with Levy –Jennings Curve & QC rules. Automatic calculation for Mean SD & CV% Direct loading for primary tubes Touch screen User Friendly GUI with Bi-directional connectivity. System General System Type: Automated, Discrete, Random Access, Patient Prioritized Clinical Chemistry Analyzer with Autoloader Throughput: 400 photometric tests/hour & 640 tests/hour with ISE (*optional ISE with Na, K, Cl, Li) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry(optional) Barcode Reader: Both for Samples & Reagents (Optional) Reactions Tray: 72 hard glass cuvettes Reaction Mixing: Dual Stirrer with variable speed Reading Volume: 180 µl On-Board Laundry: 6 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700 & 750 nm) O.D. Range: 0 - 3.0 Light Source: Halogen Lamp Detector: Silicon Photodiodes Water Consumption: < 14 liters/hour Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items Quality Control: Q.C. plot data with Q.C. Rules. Provision for lab mean. Twin plot. Caliberation: K- factor, Linear (1,2 point and multipoint) 4P and 5P Logit-log, Cubic spline,exponential, polynomial. On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimensions: Approximately 897 mm (w) x 655 mm (D) x 1170 mm (H) Weight: Approximately 200 Kg Sample Handling Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: upto 162 positions for samples/STAT/calibrator/controls with Autoloader Sample Pipetting: 2-70 µl (adjustable in 0.1 µl steps) for biochemistry,70 µl fixed for ISE capacitance probe with liquid level sensing and vertical obstruction detection , clot detection and serum indices and Reflex Testing Auto Rerun: Repeat with same, increade and decresaed volume (upto 1:150) Sample Tubes/Cups: Primary tubes of 5 ml, 7ml and 10 ml and sample cups Reagent Handling Reagent Tray: 56 positions for reagents with on-board cooling Reagent Pipetting: R1: 60 - 300 µl (Adjustable in 1 µl step) R2: 0 or 10 - 300 l (Adjustable in 1 µl step) Capacitance probe with level sensing and vertical obstruction detection System Interface Analyzer-PC: USB PC- HOST Computer: Bidirectional TCP/IP and RS - 232 PC- Printer: USB Operating System: Windows based with Touch Screen User Friendly GUI Database: Unlimited Results

Send Message
product image
Hematology

VES MATIC 5 is the next-generation automated module manufactured by Diesse Diagnostica (Italy), a highly advanced, Intelligent, Intuitive & Interactive Graphic user Interface for estimating ESR using EDTA samples. Product Features: Automated instrument for the determination of ESR directly from EDTA vacutainers Faster TAT by loading 216 sample tubes at a time Pediatric samples can be processed in microtainers Reliable results with Temperature correction facility Accurate results by eliminating manual HCT correction in Anaemic samples Real-Time monitoring of samples Detection of Lipemic, Hemolyzed, Coagulated samples Standardization in mixing with Inbuilt Mixer Analyser P. Code Product Name Pack size Vesmatic 5 165941 Next 5K Transponder 1x 5000 Vesmatic 5 165942 Next 10 K Transponder 1x 10000 Display - 19" Full HD (1920x1080) LCD with PCAP Touch Screen Peripheral Control - based on Everex distributed control system with peripheral motor control boards Operating system - Linux Analysis module - 89 Positions for Sample Tubes Sample Loading - up to 18 racks simultaneously Throughput - 190 samples per hour. First result after 28 minutes Walk away mode - Supported Continuous loading - Supported Sample mixing - with multiple 180° rotations of the tubes Collection of analysed samples - reinserted into the original loading rack LIS Connection - Multiple LIS connection protocols are available: ASTM / Proprietary Remote diagnostics - available via Ethernet connection. Printer -Alphanumeric with 58mm-wide thermal paper, 36 characters per line, speed 20 mm/sec. Imaging System - 2 high resolution cameras for sample identification and analysis; 1 standard camera for internal inspection Image processor - Dedicated Quad Core CPU with integrated GPU for real-time HD image processing of samples Temperature range in operation - from +15 to + 35°C; Storage from + 5°C to + 45°C Humidity range - from 20% to 80% without condensation Central unit - Quad core ARM Cortex A-53 CPU ARM Cortex A-53, 16 GB eMMC, 4 GB RAM Interfaces - 2 x RS232C, 2 Host USB, 1 Client USB, Ethernet Protection category - CLASS I Safety standard - EN 61010-1, EN 61010-2-081, EN 61010-2-101 EMC - EN61326-1 Installation category - II Mains voltage - 230VAC@50Hz; US/Canada: 110-120Vac@60Hz Electrical energy consumption - 420VA Fuse block - 2 x 5.0 AT (delayed) (5 x 20 mm) UL Dimensions (mm) - 850 (W) x 750 (H) x 830 (D) Weight - 80 kg

Send Message
product image
Laboratory Usage

Product Specification Model VSI-102 Usage Laboratory Display Digital pH Range 0-14 pH Type of PH Meter Table-Top Product Description We are the Leading Supplier of Temp MV Meter. pH: Range: O TO 14 pH Resolution: 0.01 pH Accuracy: 0.01 oG?(Relative) Temp.Comp: Automatic with temp. Probe & manual by keys Buffer Recognition: 4.oo,7.oo,9.20ph(automatic) slope adjustment: 80% to 120% byu derfault 100% Calibration: Manually mV(ORP): Range: 0 To ±1999mV Resolution: 1mV Accuracy: ±1 mV Caliobration: Manual Temperature: Range: 20C to 200C Resolution: o.1C Accuracy: ±0.2% Input Type: Pt 100 Calibratian: Manual Display: 16x2 alphanumeric lcd. Display Format:temp & ph or temp &orp simultaneously auto display of selected buffer Setting: By soft touch keys Storage: 1000 samples with date & time Interfacer: RS-232 centroes & computer Real Time Display: 24 hour mode with date Error Indication PH error, buffer error, orp error Power Supply 230 V±10% AC 50 HZ Digital Output: Serial RS-232 and Parallel Centronics Print Format: All Data and Date wise

Send Message
product image
Distance Meter Digital

Product Details: Weight 305 g Model No GM-06 Measuring Geometry 60 Degrees Power Supply Batter, 4 X 1.5 VA Display 4 digits backlit LCD Range 0.1 to 200 gloss units We are offering Digital Gloss Meter which is widely used in Floor maintenance, Surface cleaning quality control, Stone and tile gloss measurement, Checking printed matter, Quality control of paint and ink, Polished metal surface , measurement (chrome plating), Inspection of paint protection and waxing, Auto-body paint inspection,Surface inspection of plastic moldings, Evaluation of detergents and washers,Checking masonry and washers, Checking building exteriors. Specifications: Accuracy: ±1.0 gloss unit ( against reference standard ) Resolution: 0.1 gloss unit Repeatability: ±0.5 GU(0 ... 99.9) Measuring Area: mm ellipse Data Memorized: groups Data Output: RS 232 C serial interface Dimensions: Main unit: 156 x67x28 mm Separate Sensor: 58x28x108 mm Weight : About 305g ( including fitted batteries ) Working condition: Temperature range 0 - 40¿¿¿ and Humidity up to 85%.

Send Message
product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message
product image
Glucometer

Accu-Chek® Active blood glucose meter Personalised Diabetes Coaching Accurate, no coding, easy Item Description The Accu-Chek Active blood glucose meter packs many powerful features into a smaller size. No coding reduces handling steps, see test result averages up to 90 days, get alerts if your test strips are expired or if you’ve underdosed, re-dose within 10 seconds, set pre-and post-meal reminders to test, and more. Benefits and Features accurate: Accurate1 blood glucose measurement easy: No coding for even easier blood glucose monitoring easy-to-read display (new typeface) intuitive handling with just 2 buttons safe: Underdose detection visual double check 10 seconds re-dose option clever: Pre- and postmeal markers postprandial reminder 7,14,30 or now 90 day test averages USB interface for data transfer Remark: Previous Accu-Chek Active meter generations will be upgraded to no coding via black activation chip . Know more>> 1The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). Additional specifications Meter type : Accu-Chek Active meter (Model GB) Catalogue no. / Serial no. : See type plate on the back of the meter Test principle : Determination of glucose in fresh capillary blood by reflectance photometry. Blood glucose values can be tested in whole blood or plasma. The meter displays blood glucose values corresponding to those in plasma. Measuring interval : 10-600 mg/dL Blood volume : 1-2 μl Measuring time : Test strip in the meter: approx. 5 seconds Test strip outside the meter: approx. 08 seconds Power supply : 1 battery (type CR2032) Battery life : approx. 1000 tests or approx. 1 year Automatic power-off : after 30 or 90 seconds depending on operating status Memory : 500 test results with time and date, as well as 7, 14, 30 and 90 days averages Temperature : During testing: +8 to +42°C During storage without battery: -25 to +70°C During storage with battery: -20 to +50°C Atmospheric humidity : During testing: up to 85% relative humidity During testing: up to 93% relative humidity Altitude: Sea level to 4000 m Dimensions : 97.8 x 46.8 x 19.1 mm Weight : Without battery: approx. 46 g With battery: approx. 50 g Display : 96-segment liquid crystal display (LCD) Interface : USB (Micro B) Safety class : III Electromagnetic compatibility : The Accu-Chek Active meter meets the electromagnetic immunity requirements and the electromagnetic emissions requirements as per EN 61326-2-6 and EN ISO 15197 Annex A. The chosen basis for electrostatic discharge immunity testing was basic standard IEC 61000-4-2. Performance analysis : Calibration and traceability: The performance data for the Accu-Chek Active bGM system was calibrated using venous blood containing various glucose concentrations. Reference values are obtained using the hexokinase method, which is calibrated using the ID-GCMS method. Accuracy performance : The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). How to use Accu-Chek Active blood glucose meter Testing your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in 4 simple steps. Insert the glucose test strip Prick your finger with the lancet to draw out a blood drop. Carefully touch the blood drop onto the green field of the test strip. Read the blood glucose result.

Send Message
product image
Clinical Chemistry

Find the Best Semi Automatic Biochemistry Analyzer from Accurex. Buy Acculab At 112 Plus (Semi Auto Biochemistry Analyzer) which is the best Biochemistry Machine with numerous features like Filter Check, Self-check operation for optical filters, Checks the absorbance of each of the 7 filters & free position, Ensures that all the filters are in good working condition. This Biochemistry Analyzer has Improved ergonomic touch screen display, ensures strain free viewing with End point, kinetic, fixed time & absorbance mode. FILTER CHECK • Self-check operation for optical filters. • Checks the absorbance of each of the 7 filters & free position. • Ensures that all the filters are in good working condition. WORKLIST • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. LAMP SAVING • Lamp saving option available ensuring long lamp life. • The lamp can be turned off in case of sporadic sample workload ALARMS • Audio alarm is sounded when results are higher (S) or lower (L) than reference range ensuring that all abnormal samples are flagged for further review. • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design Methodology: End point, kinetic, fixed time & absorbance Calibration: Single standard/multi-point linear/multi-point non-linear Programmable channels: 112 Memory: 3200 results Quality control: Comprehensive QC software with L-J graph Light source:Quartz-Halogen lamp 12V / 20W Photometric range: 0.0000 to 3.0000 Abs, Resolution : 0.0001 Abs : Drift : 0.002 Abs/hour Wavelength range: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm & 1 free optional position ; Half Bandwidth < 8 nm : Stray light : < 1.0 % at 340 nm, Stainless steel body with quartz window; Optical path 10 mm Flowcell: Stainless steel body with quartz window; Optical path 10 mm Measuring volume: 32 μl Programmable aspiration volume:: 500-2000 μl Temperature control: Peltier elements : 25°C, 30°C & 37°C ±0.1°C Input: Ergonomic LCD touch screen display Printer: Built-in high speed thermal printer Interface: RS-232 serial port Dimension / Weight: 450 x 360 x 140 mm / 11.5 kgs Operating environment: Temperature: 15-30°C ; Humidity: 20-80 % Power requirement: AC 110-220 V ±10%, 50/60 Hz Safety Information • The position of the LCD display has been designed to reduce cervical (neck muscle) strain during continual use. • The aerial view display design makes it possible to view the screen from multiple perspectives, (standing or sitting, with equal clarity). Direction for Use • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. Other Info • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design

Send Message
product image
Hematology

Buy the Best Automated Hematology Analyzers – Acculab CBC 360 Neo. This Hematology Analyser Machine is Truly Automated for self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance. CBC 360 Neo is 3 part hematology analyzer from Accurex & is Automated for Walk-away Operations. Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Automation for Walk-away Operation: Auto Self-check : Automatic aspiration of reagents & rinsing of tubings on startup Auto Blank : Background test is run automatically on startup Auto Print : Automatic printing of report with / without histogram Auto Sleep : Dormancy status is entered after a set period of non-operation Auto Alarms : Audio / visual alarms in case of system errors & abnormal results Auto Clean : Automatic rinsing options available to maintain the system Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Specifications: Measurement principle: Electrical resistance for counting RBC, WBC & Platelets Colorimetric estimation of HGB at 540 nm Parameters: WBC, LY, MO, GR, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR Throughput: 60 samples/hour Micro-aperture: WBC : 100 um RBC / PLT : 68 um Sample type: Whole blood or pre-diluted sample Sample volume: Whole blood (venous blood) : 10 ul Chamber: Pre-diluent (capillary blood) : 20 ul, Pre-diluent (capillary blood) : 20 ul Reagents: Dual chamber : RBC / Platelets & WBC / HGB Quality control: 4 QC options : L-J, X-B, X-R & X QC, Graphs plotted with 31 data points Data memory: Upto 100,000 (with histogram) Display: 10.4 inch LCD with 640 x 480 resolution Printer: Built-in thermal printer Interface: Support RS-232C, standard network port and USB; keyboard and mouse Operating environment: Temperature : 15˚C – 35˚C, Humidity : 85% RH Electrical specification: Voltage : AC 110V/230V 23V Frequency : 50/60 Hz, Power : 180W Fuse specification : 250V/3A Dimensions / Weight: 670 x 515 x 640 mm / 27.5 kgs Specification Acculab CBC 360 Neo – Fully Automated Hematology Analyzer Features: 3-part differentiation of WBC Automated for — self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance High processing speed : 60 samples/hour Multi-parameter estimation : 20 parameters categorized according to corpuscle type for easy reporting Direct command keys for Mode, Prime, Flush, Drain & Record / Print for faster operation Run / Standby indicator lights denote the analyzer status i.e. test is being run or analyser is ready to test Whole blood/ Pre-diluent indicator lights denote the sample type in use i.e. whole blood/ pre-diluent Dual sample mode with low sample volume: Whole blood (venous) mode : 10 ul; pre-diluent (capillary) mode : 20 ul Audio alarm indication for abnormal findings or system errors 4 QC methods : L-J, X-B, X-R & X QC Comprehensive QC graphs with 31 data points for each parameter Internal & external probe cleaning facility Dormancy mode available to reduce power consumption Memory : 100,000 (with histogram) Safety Information • Large 10.4 inch single screen color display of all 21 parameters and 3 histograms • Sequential arrangement of WBC, RBC & PLT parameters for convenient reporing •Easy to understand & icon-based arrangement of menu for fast and convenient testing Direction for Use • WBC Histogram: R1, R2, R3, R4 & RM indications on histogram show specific abnormalities in the histogram & the probable causes • Platelet Histogram: PM indication is given when the boundary between PLT & RBC is ill-defined thus avoiding misclassification Other Info High voltage cautery function is useful in disintegrating obstinate protein or serum clog in the tubing

Send Message

Still searching for
rs 232 c serial interface dimensions?