Jaipur
+918529833535

'risc processor power requirements'

Items tagged with 'risc processor power requirements'

product image
Clinical Chemistry

Fully automatic, easy to operate • Bichromatic optic system with 4 wavelengths • 8-channel optic fibre system, reading whole plate in 5 seconds • Large LCD display, Win CE compatible operating system • Touch-screen or external mouse • Large memory to store 500 test parameters and 10000 results • Plate shaking feature • Can perform up to 12 different tests in one plate • Built-in modem support for long-distance maintenance and software upgrade (optional) • Multi-forms in result output including patient comprehensive report (optional) Vessel: Standard 96-well microtiter plates, or strip trays Linear Measurement Range: 0.000-3.500Abs Calculation Modes: Single point calibration, uptake mode, point-to-point curve fit, polynomial regression, linear regression (log and linear), cutoff absorbance, multipoint absorbance Wavelengths: Standard 405,450,490 and 630nm (340-700nm) four free position for optional filters (300-800nm) Accuracy: +/- 1% Light Source: Tungsten lamp (8V/50W) Mixer: Variable time and speed Display: 120mm x 90mm LCD Input: Touch-screen or external mouse Printer: External printer Memory: 500 tests and 10000 results Interface: RS-232 and parallel port Processor: RISC processor Power Requirements: 110V-260VAC, 50-60HZ Dimensions: 450mm(L) x 330mm(W) x 140mm(H) Weights: 10kg Certification: ISO 9001

Send Message
product image
Critical Care

Product Description: Medica Corporation’s EasyLyte® analyzer is a completely automated, microprocessor-controlled electrolyte system that uses ISE (Ion Selective Electrode) technology to make electrolyte measurements. The EasyLyte measures combinations of Na+, K+, in whole blood, serum, plasma, or urine. EasyLyte incorporates state-of-the-art electronics and an innovative ergonomic design that differentiates it significantly from competitors. The analyzer also stores quality-control data that is easily accessible. Patient histories are immediately retrievable for evaluation. EasyLyte analyzers combine simple yes/no prompted operation, low maintenance, and high reliability into one economical design. Product Features: EasyLyte is Easy to Use, Easy to Operate, Easy to Maintain The entire menu is driven by 2 simple buttons Results are displayed on LCD screen as well as printouts EasyLyte does 2 point as well as 1 point calibration Facility to analyze different type of samples: whole blood, serum, plasma ,urine samples EasyLyte has capillary and syringe sampling facility EasyLyte has auto probe wiping facility Analysis of electrolytes is done using 100ul of blood and 400ul of diluted urine Rate of analysis 55 secs per sample Analyzer is capable of storing 128 patients data with trilevel QC results Analyzer has modular plug in reagent pack system EasyLyte has facility for auto calibrations with a programmed interval of 4 hrs and also calibration on demand Analyzer has facility to upgrade to a walk away Electrolyte station by use of Auto Sampler It has a built in thermal printer and a RS 232 port for interfacing Product Applications: Sodium - Na, Potassium - K CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg) Reagents used with this 'EasyLyte' CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg)

Send Message
product image
Instruments

The new and improved RTR-1 uses an image processing method. During measurement, the lateral flow device is captured using a 5-mega pixel camera and the picture is analyzed using image processing algorithms for identification of either presence or absence of test line bands or test line band intensity levels. The reader converts the image into a grayscale and then classifies the intensity levels of the image in 0 to 255 grayscale range. The image processing algorithm undergoes various levels of filtering and segmentation to yield the correct intensity levels from the picture. Based on the preconfigured intensity levels, the reader classifies the band intensity and reads out the results as either positive or negative. ACCURACY: Less than 3% intra-run CV Eliminates subjective interpretation by operator FLEXIBILITY: Single mode for low volume test setting Batch mode allows for high volume test setting Result output as semi-quantitative line intensity and visual image EASE-OF-USE: Built in barcode reader provides faster test setup Touch screen interface for easy operation Lightweight (0.7kg) and portable DATA MANAGEMENT: Results presented on screen, on a printout or uploaded to reader database Storage capacity of 1,000 test results (including images) Laboratory Information System (LIS) and Wi-Fi compatible Human Machine Interface 4-inch resistive touch screen Camera 5 mega pixel CMOS camera Barcode Scanner Integrated 1 dimensional barcode scanner Printer 48 mm inbuilt thermal printer Mode Single mode and batch mode operations Port/USB Data export and software upgrade through 2 USB ports Storage Storage capacity of 1000 test results (including images) Result output “Positive or Negative” as well as quantitative test line intensity Power 12V 2A Processor ARM Cortex-A53 Platform Embedded Linux Dimension 220 mm X 170 mm X 110 mm (L x B x H) Weight 0.7 kg (Approx CATALOG # PRODUCT RTR-1 Rapid Test Reader OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT ADX-110 ELISA Reader ADX-120 Microplate Washer

Send Message
product image
Laboratory Usage

Product Specification Model VSI-102 Usage Laboratory Display Digital pH Range 0-14 pH Type of PH Meter Table-Top Product Description We are the Leading Supplier of Temp MV Meter. pH: Range: O TO 14 pH Resolution: 0.01 pH Accuracy: 0.01 oG?(Relative) Temp.Comp: Automatic with temp. Probe & manual by keys Buffer Recognition: 4.oo,7.oo,9.20ph(automatic) slope adjustment: 80% to 120% byu derfault 100% Calibration: Manually mV(ORP): Range: 0 To ±1999mV Resolution: 1mV Accuracy: ±1 mV Caliobration: Manual Temperature: Range: 20C to 200C Resolution: o.1C Accuracy: ±0.2% Input Type: Pt 100 Calibratian: Manual Display: 16x2 alphanumeric lcd. Display Format:temp & ph or temp &orp simultaneously auto display of selected buffer Setting: By soft touch keys Storage: 1000 samples with date & time Interfacer: RS-232 centroes & computer Real Time Display: 24 hour mode with date Error Indication PH error, buffer error, orp error Power Supply 230 V±10% AC 50 HZ Digital Output: Serial RS-232 and Parallel Centronics Print Format: All Data and Date wise

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range* <0.5%T over entire wavelength range* ,

Send Message
product image
Digital Spectrophotometer

Detector Silicon Photodiode Path Length 10 mm Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Specifications: Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Output % T: 0 to 100%, Abs:0 to 1.999 Conc: 0 to 1999 Detector Silicon Photodiode Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Path length 10 mm Spectral Bandwidth 10 nm Wavelength Resolution 1 nm on Display 2% digit LED Wavelength Accuracy 1 nm Repeatability ±1 nm Read out 3½ digit LED, 1 nm step Operating Temp 5 to 45°C Path length 10 & 50 mm in Model LT-38 Additional Information: Item Code: UV-Mini-1240 Yes! I am interested Spectrophotometer REQUEST CALLBACK Spectrophotometer Ask for Price Product Price :Get Latest Price Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range*

Send Message
product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message

Still searching for
risc processor power requirements?