Jaipur
+918529833535

'rfid'

Items tagged with 'rfid'

product image
Hematology

Buy the Best 5 Parts Hematology Analyzer – ACCULAB CBC 560+. This Hematology Analyser Machine is an advanced and automatic hematology analyzer, comprising 5 parts, 29 parameters, and 3 histograms assay, offers throughput of 60 tests/hour. Features: Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting and Cyanide-free method for HGB test along with 3D holographic scattergram to display the accurate 5 part differentiation of WBC. Equipped with a 14 inch touch screen and large storage capacity for 100,000 results, this hematology analyzer has interface of 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader. With CBC mode, CBC+DIFF mode, Venous whole blood, Capillary whole blood and Prediluted test mode, this hematology analyzer is an ideal unit for white blood cell counts, complete blood Measuring principle Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test Sample volumes CBC+DIFF mode: ≤ 20 μl CBC mode: ≤ 10 μl Throughput 60 tests/hour Assay Items 29 parameters, 3 histograms Display 14 inch touch screen Storage 100,000 sample results, including histograms, scattergrams and patient information Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT,PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%,BAS%,NEU#, LYM#, MON#, EOS#, BAS# 4 Research parameter: ALY%, ALY#, LIC%, LIC# Performance Item Linearity range Carry Over CV WBC 0-300 × 109/L ≤ 0.5% ≤ 2.0 % RBC 0-8.00 ×1012/L ≤ 0.5% ≤ 1.5 % HGB 0-250 g/L ≤ 0.5% ≤ 1.5 % PLT 0-3000 × 109/L ≤ 1.0% ≤ 4.0 % Interface 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader Power Consumption 400 VA Power Supply AC 220V±10%, 50/60Hz, 110V±10%, 60Hz Packaging dimension (W×D×H) 670 × 590 × 790 mm Gross Weight 53 kg Safety Information All the samples, controls, calibrators, reagents, waste and areas contacted with them are potentially biohazardous. Wear proper personal protective equipment (e.g. gloves, lab coat, etc.) and follow safe laboratory procedures when handling them in the laboratory.

Send Message
product image
Hematology

Fully Automatic Oscar Om 511 Hematology Analyzer, For Clinical, User Input: Touch Instrument Name Haematology Analyzer Usage/Application All Automation Fully Automatic Brand OSCAR Parameters CBC + 5 Diff Differential Type 5-Part Number Of Chambers 2 User Input Touch / Manual Number Of Parameters ALL Parameters Instrument Type 5 PART Cell Counter Model Name/Number OM-511 Type Of Blood Analyzer Fully Automatic Sample Mode All Method All Throughput 60 Samples Per Hour Display Digital Features Catalogs Attached Sample Volume 15ul Storage 1 Lac Results No. Of Reagents Used 2 Lyse 1 Diluent Accessories Keyboard ,Mouse ,Tubing Set ,Power Adaptor, Print Roll Calibration Automatic / Manual Chamber Type Double Chamber Depth Of Chamber 100un Detector Yes Dilution Ratio 1.0 Loading Pattern Manual Measuring Method Electric Impedance & Cytometric Measuring Principle Electric Impedance & Cytometric Measuring Range 2 SD Measuring Time 52 Sec Number Of Reading Channels 2 Number Of Squares 4 Operating Voltage 220 Power Supply 220 Reagent System Close with RFID Sample Type Whole Blood Slide Size 0.3un Test Volume 15ul Wavelength 546 Weight 20 Kg Zero Setting Blank Aperture Size RBC 80 , WBC 100 , Plt 60 Is It Portable Yes Measurement Range Mm Hr 60 Test Per Hour Portable Yes Reading Chambers 2 Direct Sample Yes Optical System Wavelength Optical Source Flow cell Height 470mm Point Of Care Yes Dimension 365x470x525mm Printer Yes - Internal Humidity 88% Operational Ambient Temperature 37% Atmospheric Pressure 85 kpa User Interface Yes Reliable Yes Minimum Order Quantity 1 Product Description Company : OSCAR MEDICARE PVT LTD Brand : OM-511 CBC 5 Part Hematology Products Specification : The Brand New Autometed 5-Part Differentials hematology analyzer. Try-angular laser scatter + flow cytometry for 5 Part WBC Counting. Whole Blood, Peripheral Blood, Pre-diluted blood. Throughput with 60 Samples / hour. 29 Parameters (Include 4 research Parameters 3 Reagents with orignal QC & Carlibrators

Send Message
product image
Diabetes

Product Features: Better precision, CV < 2.5 % Patented CLE technology enables complete elimination of labile glycohemoglobin ensuring accurate HbA1c results. HbA1c test results in 3.5 minutes with HbA2/HbF flagging. Separation of hemoglobin fractions Complete removal of labile fraction up to 10% No interference of HbF up to 10% No interference of lipemia or icterus, can run on non-fasting patient samples HbA1c reportability presence of HbS, HbC, HbD and HbE Compact bench top model User friendly touch screen operation Sampling from multiple sized primary tubes, including microcapillary collection tubes On board QC functions with Levey-Jennings and statistical calculations Unlimited storage of calibration, QC data and chromatograms No sample preparation required Simple reagent and column replacement Automated maintenance RFID reagent identification and tracking Automatic barcode identification of samples NGSP certified Calibrators and Controls IFCC traceable Complete kit with buffers, calibrator and column Product Application: Hba1c Testing Sampler Handler: 10 Position Rack Loader, positive identification by internal barcode reader Sample Type: Whole blood on EDTA K3 or K2 anticoagulant Haemolysate from EDTA whole blood samples Time for Analysis: Throughput approximately 3.5 minutes between samples Interferences: Complete removal (not separation) of labile up to 10% Sampling System: Sample Aspiration Probe coupled with a high precision, Sample Aspiration Volume: 14.5 µl in whole blood, 670 µl in lysate mode. Pump: 2 high pressure syringe pumps Detector Type: UV-Vis Reagent Traceability: RFID Printer: Built- in thermal printer with possibility to connect to external printer

Send Message

Still searching for
rfid?