Jaipur
+918529833535

'reliable diagnosis'

Items tagged with 'reliable diagnosis'

product image
Rapid Test

Intended Use Dengue NS1 Antigen FP is a rapid solid phase immuno- chromatographic test for the qualitative detection of Dengue NS1 Antigen in human Whole Blood/ Serum/ Plasma. This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of dengue infection. Salient Features Rapid ,visual test for the qualitative detection of Dengue NS1 Antigen in whole blood/serum/Plasma. Sample can be taken from Finger prick and sample required is 4µl. Based on Sandwich principle. Detection of Dengue in Seronegative stage i.e From Day 1 of fever. Detection of all 4 serotypes of dengue virus. Reliable diagnosis of both primary and secondary infection. 100% Sensitivity & 99.96 % Specificity. Shelf life: 24 month at 2-30 °C Convenient pack Size: 10 Test. Evaluated By Referral Medical college / Hospitals /Research institutes / Labs.

Send Message
product image
Rapid Test

Intended Use Dengue NS1 Antigen self-test is a rapid solid phase immune-chromatographic test for the qualitative detection of Dengue NS1 Ag in human whole blood/serum/plasma. This test is intended to be for home use with self-collected whole blood specimens from individuals aged 18 years or above( or collected by adults for individuals below 18 years of age) as well as for professional use with venous Whole blood/Serum/Plasma samples. This test is for in-vitro diagnostic use only & is designed as an aid in the early diagnosis of dengue infection patients with clinical symptoms. Salient Features Rapid, Visual, Home test for qualitative detection of Dengue NS1 antigen detection in human whole blood/serum/plasma. Finger prick sample can be used. Single test pack. All material to perform the test & its disposal are provided with the kit. Based on Sandwich principle.\ Detection of Dengue in Seronegative stage i.e. from Day 1 of fever. Detection of all 4 serotypes of dengue virus. Reliable diagnosis of both primary and secondary infection. 100% Sensitivity & 100 % Specificity. Shelf life: 30 month at 2-30 °C.

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Hemoglobin Meter

Get the fastest hemoglobin and HCT test within 10 seconds, Buy Accurex URIT-12 Hemoglobin Meter Online. This Hemoglobin tester gives Accurate & Reliable Result. The Urit 12 hemoglobin machine is the best digital hemoglobin Meter with easy 3-step operation. The hb meter is is perfectly fit for the filtration of the numbers of blood donors, POCT, and hemoglobin testing in medical examination center. etc. It works on the prinicple of Optical reflectance. Sample: Capillary or venous whole blood (13~15 ul) & Strips: Accurex H12 Hemoglobin Test Strip URIT-12 is an easy-operation, fast-testing and portable hemoglobin testing Meter, which is perfectly fit for the filtration of the numbers of blood donors, POCT, and hemoglobin testing in medical examination center (MEC) etc. Compared to HiCN-HB method, the results are satisfactory. • Fast hemoglobin and HCT test within 10 seconds • Accurate & Reliable Result • Easy 3-step operation Parameter: Hemoglobin, HCT (Hematocrit) Principle: Optical reflectance Strip: H12 Hemoglobin Test Strip Speed: 10 seconds Sample: Capillary or venous whole blood (13~15 ul) Memory: 250 test results Measuring Range: 4.0g/dL 24.0g/dL(g/L optional) Quality Control: HQ-A Hemoglonbin control solution Calibration: Factory calibrated according to ICSH Power: DC 6V (Two CR2032 Batteries) Automatization: Self-checking, auto-judging and displaying malfunction Dimension: 102mm 50mm 19mm Accuracy: accuracy ≥ 96%,the correlation is very good in the comparison between URIT-12 and ICSH method. Precision: CV < 5%,testing samples including high, medium & low concentration, the CV of 10 repeated test results is 1.8% 2.2% 2.7% respectively. Hematology analyzer is not suitable for the fast and single hemoglobin testing out of the laboratory and the fast hemoglobin filtration for numbers of blood donors, therefore, it’s very necessary to find a kind of method for fast and accurate hemoglobin testing. When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors automatically measure the change of reflectance in membrane. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Other Info Hemoglobin testing is one of the important clinical hemanalysis items. It is useful for the diagnosis of all kinds of anemia. In clinical laboratory, many test items including hemoglobin can be gotten from hematology analyzer.