Jaipur
+918529833535

'release button'

Items tagged with 'release button'

product image
Glucometer

Item Description The Accu-Chek Softclix lancing device can help make lancing easy. Its rotatable cap offers 11 fixed depth settings for different skin types. Clixmotion technology minimizes any painful side-to-side motion of the lancet, which is why this lancing device is virtually pain-free to use. Benefits and features Virtually pain-free lancing Clixmotion technology controls the lancet’s movement Less side-to-side motion of the lancet means less skin damage Turn the rotatable cap for 11 penetration depth settings for different skin types The Accu-Chek Softclix lancets are precisely manufactured for precise entry Additional specifications Penetration Depth: 11 fixed-depth options, set with the rotatable cap Penetration Range: 0.8 to 2.3 mm Lancing Technology: Clixmotion Technology Weight: 21 g Alternative Site Testing: AST cap provided Needle Diameter: 0.4 mm Gauge: 28 Coating: Silicon How to use the Accu-Chek Softclix lancing device The Accu-Chek Softclix lancing device is small and easy to operate, with one-hand priming and lancing. Pull off the cap. Insert a new lancet into the lancet holder and push it in until it clicks. Press the cap on again until it clicks. Rotate the cap until the desired penetration depth is set. Press the priming button down until it clicks. Press the lancing device firmly against the side of the fingertip. Press the yellow release button. After measuring your blood glucose, pull off the cap and slide the ejector forwards to remove the lancet.

Send Message
product image
Glucometer

Item Description The Accu-Chek Safe-T-Pro Uno lancing device keeps up with increased safety and hygienic requirements by health authorities, legislators, and health institutions. At the same time, it provides an ergonomic handling, lancing in just 3 milliseconds, and safety features that prevent accidental needle sticks. Its pre-set lancing depth makes it ready to use immediately. Benefits and Features Ready to use with a pre-set depth setting Safe-T-Technology ensures the needle is always safely stored away Stored needle prevents accidental needle sticks Ergonomical and easy to grip for safe handling Hygienic - each lancet can only be used once Beveled needle and small diameter for virtually pain-free blood sampling Equally suitable for right and left-handed use After a single use, the complete lancing device is disposed of Additional specifications Pre-fixed depth setting: Yes Penetration depth: 1.5 mm Needle diameter : 0.36 mm (28 G) Special needle cut: 3-facet cut Siliconized needle: Yes Sterility : 4 years after sterilization Single-use only: Yes Automatic retraction of needle : Yes Recognition of used device : Yes Intuitive handling : Yes How to use the Accu-Chek Safe-T-Pro Uno Simple, 2-step lancing Twist the sterility cap one quarter turn and remove it. Hold the lancing device between your index finger, middle finger, and thumb. Press the lancing device firmly against the chosen puncture site. Using your thumb, press the release button down completely. Move the lancing device away from the puncture site and discard it.

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Glucometer Plus Kit Online, it’s a smart Glucometer Machine kit. This Digital Glucometer consists of 1 Blood Glucose Meter, 10 Test Strips, 1 Multilet Lancing Device, 10 Sterile Lancets, 1 Carry Pouch, 1 Warranty Card, Test Strip Insert Sheet, 1 Battery (3V) Gluco Plus Meter is intended for use in the home & in clinical settings. There are different types of Glucometers in Point of Care (POC). XPRESSGLUCO + meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). The system is intended for use outside the body (in vitro diagnostic use only). It should be used only for self-testing blood glucose (blood sugar) and only with fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh. The system is intended for use in the home and in clinical settings. The system should not be used for the diagnosis of diabetes or for the testing of newborns. Blood glucose is measured by an electrical current that is produced when a blood samples mixes with the reagent (special chemicals) of the test strip. The electrical current changes with the amount of glucose in the blood sample. The XPRESSGLUCO+ meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). Safety Information 1. The user should not take any decision of medical relevance without first consulting his or her medical practitioner. 2. Call your doctor immediately if you experience symptoms that are not consistent with your blood glucose test results. 3. High altitudes above than 3,402 meter (11,161 ft) may affect the test results. 4. Temperatures outside the range of 10°C to 40°C (50°F to 104°F) may affect the test results. Do not test beyond of temperature range. 5. Do not perform servicing and maintenance while the meter is in use. 6. No modification of this equipment is allowed. 7. Do not use this meter near cellular or cordless telephones in a call, walkie-talkies, garage door openers, radio transmitters, or other electrical or electronic equipment that are sources of electromagnetic, radiation, as these may interfere with the proper operation of the meter. Direction for Use 1. Wash you hands and puncture sit: Wash your hands in warm, soapy water. Rinse and dry completely . Warm your fingers to increase blood flow. 2. Insert Test Strip : Remove a new test strip from vial. Be sure to tightly replace vial cap after removing test strips. Insert a test strip with the contact bar end entering into the test strip slot first. Push the test strip as far as it will go without bending it. The meter turns on automatically. 3. Hold the prepared lancing device firmly against the side of your fingertip. Press the release button. (NOTE : If you want to do alternative site testing, please refer to the “About Alternative Site Testing (AST)” section. Please consult your healthcare professional before obtaining blood from site other than your fingertip.) 4. Obtain a Blood Sample : Gently massage your finger or puncture site to obtain the required blood volume. To perform the test, you need only 0.5 μL of blood sample. Do not smear the blood sample. To obtain best accurate result, wipe off the first drop of blood and gently squeeze another drop of blood. 5. Apply Blood Sample : When the meter shows the “ ” symbol, apply blood to the opening of the absorbent channel of the test strip where it meets the narrow channel. Blood will be drawn into the test strip. If the test strip confirmation window is full, you will hear a beep. 6. Read Your Result : After the meter counts down from 5 to 1, your blood glucose test result appears along with the unit of measure, date and time. Test result is lower than the target range Test result is within the target range. Test result is higher than the target range *The default target range is 70 mg/dl to 180 mg/dl. 7. Turn Off the Meter : This blood glucose result is automatically stored in the meter memory. Turn the meter off by removing the test strip. Discard the used test strip carefully to avoid contamination. 8. After use, twist off the Lancing Device Cap. Push the exposed tip of the lancet into its Protective Cap. 9. Slide the Lancet Ejector forward and disposing the used lancet in an approved container. Discard the used lancet according to your country’s safety regulations. Replace the Lancing Device Cap. Other Info •Use only XPRESSGLUCO+ Control Solution with your XPRESSGLUCO+ meter. •Check the expiration date on the bottle. Do not use if expired. •Use within a period of 90 days from the date that you first open it. Record the discard date on the control solution bottle when you first open it to serve as a reminder to discard after 90 days. •The control solution ranges are printed on the label of the XPRESSGLUCO+ Blood Glucose Test Strip vial. They are not recommended target ranges for your blood glucose. •For in vitro diagnostic use. •Do not add any liquid to the XPRESSGLUCO+ Control Solution. •Do not take internally or inject.

Send Message
product image
Clinical Chemistry

The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins such as cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers: Throughput of up to 1,800 tests per hour to keep pace with workload peaks 200 basic metabolic panels per hour to meet turnaround-time demands Large onboard reagent capacity and optional concentrated reagents to reduce interruptions Optimal standardization of reagents and systems for efficient consumable usage Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 1800® Clinical Chemistry System pushes the limit of productivity in the core lab and meets the turnaround-time (TAT) goals of today’s laboratories. Its extensive menu allows integration of general clinical chemistry testing with testing for drugs-of-abuse, TDM, special chemistry, and specific proteins such as cystatin C and CardioPhase® hsCRP. Automation-ready design Point-in-space aspiration enables connectivity to a track, VersaCell® System. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Peak productivity Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks. Throughput of 200 basic metabolic panels per hour helps to meet turnaround-time demands. Automatic Sample Retain technology lets you perform reruns and dilutions without the need to retrieve primary tubes. Consolidate chemistry testing on one system with a comprehensive menu, consistent cycle times, speed, and open application capability. Total system reliability Minimal-maintenance ISEs Robust hardware and simplified software design, with automatic calibration validation and tracking Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion Direct water connection Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Easy efficiency Large onboard reagent capacity and optional concentrated reagents reduce interruptions. High-resolution touchscreen delivers push-button operation. Reagent pause capability and onboard Sample Pause button make loading easy. Minimal maintenance requirements, including no-maintenance oil bath, reduce hands-on time. Sample integrity checking, include serum indices reporting, short-sample flagging, and clot detection, reducing the need for manual intervention.

Send Message
product image
Clinical Chemistry

ADVIA Chemistry XPT System An advanced, automated clinical chemistry analyzer for high-volume laboratories The ADVIA® Chemistry XPT System provides timely, reliable results with continuous operation to meet the chemistry workloads of the most demanding laboratories. Delivers high throughput of up to 2400 tests per hour. Manages comprehensive testing with a menu of more than 115 assays. Improves workflow using automation and system technologies such as micro-volume and aliquot retention. Features & Benefits The ADVIA Chemistry XPT System*** is engineered for continuous operation and timely, accurate results—supporting you to reach your full potential today and be prepared for tomorrow. With an advanced user interface that is easy to use and VeriSmart Technology to support accuracy of testing, the ADVIA Chemistry XPT System predictably and consistently delivers timely, reliable results to meet expanding workloads. Simplified, Continuous Operation Simplify operation and training with the intuitive, icon-driven user interface. Extend walkaway times with concentrated reagents that provide high test capacity onboard. Quickly load most system fluids on the fly. Automate calibration, QC, startup, and shutdown. Consistent, Predictable Turnaround Time and Accuracy Offer a comprehensive chemistry menu of over 115 assays, including general and specialty chemistry, DAT, TDM, and specific proteins. Push productivity with a throughput of up to 2400 tests per hour (1800 photometric, plus 600 ISE). Control testing: STAT and specialty samples can always be front-loaded while an automation track is running. Designed for Automation Adapt and grow with direct connectivity to Siemens Healthineers and . Simplify your laboratory operations with connectivity to IT solutions including , , and . Increase productivity and efficiency with direct-from-track sampling and onboard aliquoting that allows samples to be immediately released to the next workstation. Do More with Less Reduce blood-draw requirements with micro-volume technology that uses a single 30 μL sample for up to 15 tests. Eliminate sample callback with automated, pre-programmable dilution, reflex, and rerun testing that uses an onboard aliquot. Improve workflow and accuracy with VeriSmart echnologies that perform hardware and software checks at all stages of sample processing.

Send Message
product image
Hematology

The BC-3600 Hematology analyzer features closed tube sampling via a single push button. A built-in large 10.4 inch color touchscreen allows maximum visibility. Hemoglobin analysis is performed using cyanide-free reagent. The analyzer processes up to 60 samples per hour and stores up to 40,000 results with histograms. The barcode reader and optional LIS connectivity enable seamless sample data transmission. Nearly all scheduled maintenance procedures are automated by touch buttons. The intuitive software enhances workflow efficiency and provides operators with a pleasant user experience. Key Features CBC plus 3-part differential, 16 parameters + 3 histograms 60 samples per hour, 1 min per CBC Closed tube sampling, minimize operational biohazard Built In diluent dispenser for predilution mode All-in-one CBC result screen display; results at a glance Touch button maintenance procedures One maintenance reagent only – probe cleaner Storage capacity of 40,000 results with histograms Uploadable QC files; ensure accuracy and time efficiency Parameters WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT,MCV, MCH, MCHC, RDW,PLT, MPV and histograms for WBC, RBC, PLT Principles Electrical impedance method for cell counting and Cyanide - free for hemoglobin Sample Volume Prediluted 20µL Whole Blood 21µL Carryover WBC/RBC/HGB≤0.5% PLT≤1.0% Connectivity 4 USB ports (for external printer, software upgrade, barcode reader,keyboard and mouse), LAN port (1), RS232 (1) Printout Thermal recorder, 50mm width paper, various printout formats, external printer (optional) Product Specification Brand Mindray Differential Type 3-Part Model Name/Number BC 3600 Display Type Large color touch screen Resolution 800x600 Usage/Application Hospital Throughput 60 samples per hour Power Supply AC 100-240V,50/60 +-1Hz Weight 62 lbs Dimension 16 in(W) x 18 in(H) x 18 in(D) Humidity 30%-85% Temperature 15 ~30 Deg C Minimum Order Quantity 1

Send Message
product image
Medical Equipment

Brand new BeneHeart D60 has made a major breakthrough for the industry. The multi-talent D60 integrating 12-lead ECG and POCUS, gives strong boost for on-site diagnosis. The first ever int-ext dual-factor evaluation system with closed-loop rescue approach combining resuscitation, debriefing, and training, supports continuous improvement of the rescue quality. With full touch screen and key hard buttons allowing for quick and neat control, BeneHeart D60 effectively expands rescue potential and makes rescuers more confident. Smart Touch, More Intuitive With advanced high-definition capacitive touch screen technology and flat UI design, D60 brings a clearer visual experience and more smooth operation feelings, making efficiency at your fingertips. First 9” display with 1200 x 1020 resolution Auto-brightness Gesture-control touchscreen Keep physical knob and buttons for key operations With the intelligent sensing, you can operate D60 normally, even if - the screen is spilled with liquid - wearing up to 5 layers of gloves All in one-360J Manual defib /AED /Pacing /Monitoring: ECG, SPO2, NIBP, CO2 Ultra-light Only 4.2kg (with battery) for exceptional portability Versatile paddles-External paddles with contact indicator improve usability for clinicians Visual AlarmSight™ Problem-solving support with graphical visualization One Device with Multi-talent

Send Message
product image
Medical Equipment

Since the company was founded, Mindray has been continuously exploring new ways to improve diagnostic confidence. Powered by the most revolutionary ZONE Sonography® Technology, Resona 7’s new ZST+ platform brings ultrasound image quality to a higher level by zone acquisition and channel data processing. As well as the premium level image quality, Resona 7 also enhances clinical research capabilities with the revolutionary V Flow for vascular hemodynamic evaluation, and the most intelligent plane acquisition from 3D datasets for fetal CNS diagnosis. Combining the most intuitive gesture-based multi-touch operation and all the essential clinical features, Resona 7 is truly leading new waves in ultrasound innovation. With core platform advantages of ZST+ The channel data based ZST+ is an extraordinary innovation, representing an ultrasound evolution. Transforming ultrasound metrics from conventional beamforming to channel data based processing, ZST+ is able to deliver multiple imaging advances: Advanced Acoustic Acquisition, Dynamic Pixel Focusing, Sound Speed Compensation, Enhanced Channel Data Processing and Total Recall Imaging. Advanced features V Flow V Flow (Vector Flow) is a novel approach for vascular hemodynamic analysis. V Flow uses color coded vector arrows to indicate the velocity’s magnitude and direction of blood cells. With ultra-high frame rates, it provides extremely accurate and angle-independent visualization of complex vascular hemodynamic profiles. With comprehensive data information, V Flow is the most valuable tool for vascular clinical research. resona-7-fig3-1-pc UWN+ Contrast Imaging UWN+ (Ultra-Wideband Non-linear Plus) CEUS enables the Resona 7 to detect and utilize both the 2nd harmonic and non-linear fundamental signals, generating significantly enhanced images, resulting in greater sensitivity of minor signals and longer agent duration with lower MI. Forwarding smart to clinical intelligence The Resona 7 elevates clinical intelligence with a complete solution that enables clinicians to manage both routine and advanced studies more efficiently,consistently, and accurately, from acquisition to calculation. As an example, Smart Planes CNS shows exceptional intelligence in accurate diagnosis and analysis of the fetal central nervous system (CNS) Smart Planes CNS Mindray’s exclusive pioneering technology positions the Resona 7 as the industry’s first ultrasound system to allow fully automatic and accurate detection of the most significant planes and frequently used measurements of fetal CNS, leading to intelligent diagnosis, improved throughput, and reduced user dependence. Smart Planes CNS provides a user-friendly tool that greatly improves scanning efficiency through increased accuracy coupled with automated operation. With a simple button click on a 3D fetal brain volume image, the standard CNS scanning planes (MSP, TCP, TTP and TVP) and a range of related anatomical measurements (BPD, HC, OFD, TCD, CM and LVW) are obtained immediately. Smart Face Acquiring an optimal view of the fetal face in 3D ultrasound is cumbersome and time-consuming. In some cases, it is impossible to get rid of the occlusions such as cord, placenta, uterus and extremities. The new Resona 7 with Zone Intelligence provides a fast and intelligent optimization for fetal face with simply one-touch. It can immediately remove occlusions in the volume data, eliminate unwanted noise information, and generate an optimal view of the fetal face with minimal effort. Ergonomics The Resona 7 is designed around you. Gesture-based operation opens up a new trend in cart-based ultrasound with an agile, smart, and intuitive user experience beyond your expectations. Gel warmer’s three level temperature and swiveling angle adjustment of the control panel delivers great patient comfort and user convenience.

Send Message
product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message

Still searching for
release button?