Jaipur
+918529833535

'reflectance photometer measuring system'

Items tagged with 'reflectance photometer measuring system'

product image
Urinalysis

Product Description: This is a continuous loading system for automatic movement, timing, measurement & evaluation of urine test strips. Product Features: High Throughput - High Memory Capacity Easy operation via touchscreen Product Application: Automated reading of Urine test strips that avoids subjective errors in visual reading Technical Specifications: System: Continuous loading Semi-automated Urine test strip analyzer Type: Reflectance photometer Measuring System: Wavelengths – 460 nm, 530 nm, 610 nm Memory: 1000 results Throughput: 400 tests /hr User interface: LCD touchscreen (800 x 480 pixel) Printer: Built-in Thermal Printer Certificates: CE Physical Dimensions: 300 x 287 x 148 mm Weight : 3.2 Kg Test Strips: DekaPHAN Laura & MicroalbuPHAN Laura Parameters: Specific Gravity, Leucocytes, Nitrite, pH, Protein, Glucose, Ketone, Urobilinogen, Bilirubin, Blood & Microalbumin, Creatinine Optical QC: Grey QC strip System Interface: Communication via RS232 & USB port Host Protocol: Uni-directional Sample Identification: Sample ID via keyboard entry, barcode reader Power source: AC 100-240V/50-60 Hz Power consumption: ≤45 W

Send Message
product image
Urinalysis

Product Description: Laura SMART is a simple, quick and compact solution for routine clinical laboratories, ambulances and para clinics. It helps in automated timing, measurement and evaluation of urine test strips. Product Features: Two measuring modes (Standard: 60 samples/h & Smart Timing:240 samples/h) Portable mode using batteries Calculation of Microalbumin & Creatinine ratio Easy operation via touchscreen Product Applications: Automated reading of Urine test strips avoiding subjective errors in visual reading System: Semi-automated Urine strip analyzer Type: Reflectance photometer Measuring System: Wavelengths – 470, 540, 650 nm Memory: 400 results Throughput: 60 tests/hr in Normal Mode & 240 testes/hr in Smart mode User interface: Color TFT LCD display Printer: Built-in Thermal Printer Certificates: CE Physical Dimensions: 230 X 127 x 110 mm Weight: 0.8 Kg Test Strips: DekaPHAN Laura & MicroalbuPHAN Laura Parameters: Specific Gravity, Leucocytes, Nitrite, pH, Protein, Glucose, Ketone, Urobilinogen, Bilirubin, Blood & Microalbumin, Creatinine Optical QC: Grey QC strip System Interface: Communication via RS232 & USB port Host Protocol: Uni-directional Sample Identification: Sample ID via keyboard entry, barcode reader Power source: AC 90-230V/50-60 Hz Power consumption: 20 W max./1 W standby

Send Message
product image
Laboratory Usage

Product Description We are engaged in manufacturing and supplying of flamephoto Meters. This is a measuring device for ascertaining presence of metal ions like calcium, potassium, lithium and sodium in the inorganic chemical compounds. Most flamephoto meters are equipped with sodium or potassium filters. We supply both single and dual chambers flamephoto meters to cater the varying needs of our esteemed clients. Specifications: Digital Flame Photometer( Single chamber) Model No. Ist Lab-65 Digital Flame Photometer (Single Channel) with filter (NA K) 3 1/2 digit LED display (PPm)along with compressor and other accessories Ca Li filter can be provided on request. Digital Flame Photometer (Dual Channel) Model No. Ist Lab-66 Single aspirations,with filter (NA K).Final result in ppm,2 1/2 digit dual LED display for simultaneos result along with compressor accessories

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 190-1100 nm Optical System Double Beam Spectral Bandwidth 1 nm Wavelength Accuracy 0.1 nm Wavelength Repeatability 0.1 nm Photometric Accuracy 0.3 % T Photometric Range 0-200 % T, -0.3 - 3.0 A, 0-9999 C Photometric Repeatability 0.2 % T Stray Light Less than equal to 0.05%T Stability 0.001 A/h Detector Silicon Photodiode Lamp Type Deuterium Lamp, Tungsten Halogen Lamp Baseline Flatness 0.001 A Noise 0.001 A Data Output Port USB Port Display Graphic LCD (320*240 Dots) Dimensions 630 x 430 x 206 mm Printer Port Parallel Port Weight 26 kg We are the leading manufacturer of a wide range o These products are UV-VIS Spectrophotometer easy to operate and highly appreciated for its durability. Specifications: Wavelength Range 190-1100 nm Mode Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics Scanning Speed Fast / Medium / Slow Wavelength Accuracy 0.1 nm Bandwidth 1 nm Wavelength Reproducibility 0.1 nm Photometric Display Range 0-200 % T, -0.3 - 3.0 A, 0-9999 C Photometric Accuracy 0.3 % T Photometric Repeatability 0.2 % T Stability 0.001A/h @ 500 nm Baseline Flatness 0.001 A Noise 0.001A Stray Light < 0.05% T @ 220nm, 360 nm) Data Output Port USB Printer Port Parallel Port Display Graphic LCD (320*240 Dots) Lamps Deuterium Lamp & Tungsten Halogen Lamp Detector Silicon Photodiode Dimensions(L*W*H) 630 x 430 x 206 mm Net Weight 26 Kg

Send Message
product image
Urinalysis Analyzer

The Orinalyser U500 Urine Analyser is a Multi Strip Urine Reagent Strip Analyser. It is a reflectance photometer that analyzes the intensity and color of light reflected from the reagent areas of a urinalysis reagent strip. The analyser throughput is 500 tests per hour and the measuring cycle is 7 seconds per test. •500 tests/hour throughput •Large LCD touch screen offers simple menu navigation •Auto strip detection and alignment for better efficiency •Uniquely designed strip platform and waste tray unit for easy one-step cleaning •Autocalibration and waste disposal. •Auto flag for abnormal results •RS232C & USB port for data transfer

Send Message
product image
Glucometer

Accu-Chek® Active blood glucose meter Personalised Diabetes Coaching Accurate, no coding, easy Item Description The Accu-Chek Active blood glucose meter packs many powerful features into a smaller size. No coding reduces handling steps, see test result averages up to 90 days, get alerts if your test strips are expired or if you’ve underdosed, re-dose within 10 seconds, set pre-and post-meal reminders to test, and more. Benefits and Features accurate: Accurate1 blood glucose measurement easy: No coding for even easier blood glucose monitoring easy-to-read display (new typeface) intuitive handling with just 2 buttons safe: Underdose detection visual double check 10 seconds re-dose option clever: Pre- and postmeal markers postprandial reminder 7,14,30 or now 90 day test averages USB interface for data transfer Remark: Previous Accu-Chek Active meter generations will be upgraded to no coding via black activation chip . Know more>> 1The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). Additional specifications Meter type : Accu-Chek Active meter (Model GB) Catalogue no. / Serial no. : See type plate on the back of the meter Test principle : Determination of glucose in fresh capillary blood by reflectance photometry. Blood glucose values can be tested in whole blood or plasma. The meter displays blood glucose values corresponding to those in plasma. Measuring interval : 10-600 mg/dL Blood volume : 1-2 μl Measuring time : Test strip in the meter: approx. 5 seconds Test strip outside the meter: approx. 08 seconds Power supply : 1 battery (type CR2032) Battery life : approx. 1000 tests or approx. 1 year Automatic power-off : after 30 or 90 seconds depending on operating status Memory : 500 test results with time and date, as well as 7, 14, 30 and 90 days averages Temperature : During testing: +8 to +42°C During storage without battery: -25 to +70°C During storage with battery: -20 to +50°C Atmospheric humidity : During testing: up to 85% relative humidity During testing: up to 93% relative humidity Altitude: Sea level to 4000 m Dimensions : 97.8 x 46.8 x 19.1 mm Weight : Without battery: approx. 46 g With battery: approx. 50 g Display : 96-segment liquid crystal display (LCD) Interface : USB (Micro B) Safety class : III Electromagnetic compatibility : The Accu-Chek Active meter meets the electromagnetic immunity requirements and the electromagnetic emissions requirements as per EN 61326-2-6 and EN ISO 15197 Annex A. The chosen basis for electrostatic discharge immunity testing was basic standard IEC 61000-4-2. Performance analysis : Calibration and traceability: The performance data for the Accu-Chek Active bGM system was calibrated using venous blood containing various glucose concentrations. Reference values are obtained using the hexokinase method, which is calibrated using the ID-GCMS method. Accuracy performance : The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). How to use Accu-Chek Active blood glucose meter Testing your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in 4 simple steps. Insert the glucose test strip Prick your finger with the lancet to draw out a blood drop. Carefully touch the blood drop onto the green field of the test strip. Read the blood glucose result.

Send Message
product image
Clinical Chemistry

The HumaStar 80 is a clinical chemistry analyzer that combines the low maintenance effort of photometers with the convenience of automated sample processing. Its key features include autodiagnosis for electronic and mechanical components, emergency sample analysis and LIS interface. Highlights Original instrumentation provided by Human Diagnostics Diamond Down-To-Frame® refurbishment provided. Refurbishment includes disassembly and total restoration. Process continues with assembly, repair, and diagnostics. Certification concludes with calibration, QC and QA validation. Contact Diamond for pricing, specifications and availability. Assays Total assays tested: 48 - Acid Phosphatase (ACP), Alanine Aminotransferase (ALT) Entry-level, optimized batch analyzer > Up to 80 tests per hour > 40 tests per hour typical> 20 reagents on board> 54 sample positions> 18 μl micro flow cell> STAT function> Intelligent optimized batch mode> English, French, Italian, Spanish software> Automatic re-run with sample dilution> Integrated maintenance schedule> Built-in QC management> Heated pipetting system> Dimensions: 72 x 73 x 45 cm > Net weight: 42 kg> 230/110 Vac, 350

Send Message
product image
Immunology Analyzer

Product Description: The LisaScan EM Microplate Reader is an economical, compact and versatile 8 channel ELISA reader which can be adapted to various ELISA applications. It is India’s largest selling automated microplate ELISA reader Product Features: Wavelength Range: 400 to 750nm with a dynamic measurement range of 0.0 to 4.0 O.D 100 user-programmable test storage Inbuilt thermal printer for reports & graphs Auto self-check on start-up & external printer connectivity Compatible to various plate geometrics-96 well microplates ( Flat, U & V bottom) Wavelength selection: Monochromatic, bi-chromatic & multi-chromatic* Reading time 8 sec. for single wavelength using 8-channel optics User-friendly inbuilt operation software with 7000 sample test results storage User interface: High Resolution LCD display with 20 Keys Rugged waterproof & membrane panel Computer linked ELISA data management software - Eli-LIMS* CE marked Inbuilt shaking facility,Three Linear Speeds - Low, Medium and Fast Reports can be printed using internal thermal or external printer No need of manual calculations and documentation Documentation ease – Reports can even be stored using optional Eli-LIMS software Computer can be connected Extensive ELISA data management Product Applications: ELISA System type: Open System Plate types: 96 well plates Wells Type: U, V and Flat bottom wells Operating Modes: Absorbance Quantitative Qualitative Semi-Quantitative Kinetic Mode Measurement Modes: Continuous / Step Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set Wavelength Selection: Monochromatic Bi-Chromatic Multi-Chromatic* (Maximum 4) Calculation Modes: Non-linear Standard Cut-off Index Formula Column Subtraction Linear Regression Point to Point Cubic Spline Linear – Log Blank Options: Blank, Control, Assay Validation equations Against Air, Well Plate, Column, Column-mean Row, Row mean Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters Test Programs: 100 totally “open” Test Programs Photometer: Measuring system: 8-Channel optical system Lamp Source: Tungsten Halogen with Lamp saver function Wavelength Range: 400 to 750 nm Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass Dynamic Range: 0.0 ~4.0 OD Photometric accuracy: < 1% at 2.5 OD at 450 nm Photometric resolution: 0.001 OD Linearity: <1% at 2.5 OD at 450 nm Measurement Time: SPEED : 8 Seconds single wavelength NORMAL : 17 Seconds single wavelength Display: High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm Keyboard: Rugged waterproof & membrane panel PC Communication: USB Based Protocol compatible with Eli-LIMS and TNW Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor). Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves. Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored. Lab name in Print-out Lab name in Display Collated reports Print-out of Normal Range along with the result (on external printer only). Graphs can be printed on Thermal Printer Sorted by: Date I.D. Both by Date & I.D. Test Plate ID Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad. Operating Temperature: 20˚ C to 40˚ C Storage Temperature: -10˚ C to 50˚ C Humidity: Max. 80% RH, non- condensing Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter 115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified) Dimension: 502 mm X 369 mm X 216 mm Weight: 7 Kg

Send Message
product image
Clinical Chemistry

Product Description: An advanced & versatile semi automated analyzer for all Clinical chemistry, Electrolytes, Immunoturbidimetric assays and Coagulation test Product Features: Semi automated analyzer 56 direct access keys Temperature selection for 20oC - 40oC in steps of 1oC 5 reporting formats Online display of reaction curve Result recalculation Three levels of quality control with Levy Jennings plot 5 reporting formats USB port interface for PC & printer Product Applications: Entire range of Clinical chemistry, Electrolytes, Immunoturbidimetric assays and Coagulation Optical Module: Static photometer with photometric range (340-670) 8 Interference filters 340, 405, 450, 505, 546, 578, 600 and 670 n.m. Silicon photodiode detectors Photometric range from 0 to 3.0 OD Quartz Halogen lamp of 12V, 20W Measuring Module: Unique Triple cuvette system 18 µl Flow cell 10 mm Square cuvette 6 mm Round glass tube with adaptor Peltier temperature control: 20°C-40°C in steps of 1°C Peristaltic Pump Minimum aspiration volume 200 µl Analysis Modes 1-point linear Rate A non-linear 2-point linear 1-point sample blank linear 1-point non-linear 1-point sample blank non-linear 2-point non-linear Absorbance Rate A linear Coagulation Memory: 200 User defined test programs 1000 test result Reagent Blank 3 Levels of QC Result Recall: Collated Reports by Date, ID, Date & ID Test & Date wise Patient Demographics Built-in QC: Daily and monthly monitoring for 3 Levels Levy-Jenning QC graphs Display: High resolution graphics LCD with backlight. View Area: 120 x 92 mm Keyboard: 41 Multifunction Keys and 6 dynamic keys Printer: In built high resolution graphic thermal printer Interface: USB connectivity to PC Direct printer connectivity through USB port Port for External keyboard Power: External Universal SMPS adapter 18V DC, 70W, 115/230V AC (± 10%), 50/60 Hz Size: (mm): 205 (H) x 450 (W) x 300(D) Weight: Approx. 7 Kgs. Optional Accessories: External 16 Position Dry Block Incubator

Send Message

Still searching for
reflectance photometer measuring system?