Jaipur
+918529833535

'reagent set'

Items tagged with 'reagent set'

product image
Clinical Chemistry

Infinite Liquid a-Amylase 12 ml Diagnostic Reagent from Accurex (Pack Size : 6 x 2 ml). a-Amylase reagent is used for determination of amylase activity based on kinetic method using Gal G2 – a CNP. Amylase is a ready-to-use reagent. Normal amylase level is 40 to 140 units per liter (U/L) or 0.38 to 1.42 microkat/L (µkat/L). Infinite a-Amylase can be used on any Spectrophotometer, Discrete semiautomated & Automated analyzers. Reaction type is Kinetic. Accurex Biomedical is the first biochemical reagents manufacturing company in India About Infinite a-Amylase ‘is a reagent set for determination of amylase activity based on kinetic method using Gal G2 – a CNP. Infinite a-Amylase is a ready-to-use reagent. Infinite a-Amylase can be determined in just 21/2 minutes at 37°C. Infinite a-Amylase is linear upto 2000 IU/1. Infinite a-Amylase is a High Stability Reagent. Infinite a-Amylase can be used on any Spectrophotometer, Discrete semiautomated and Automated analyzers. Programme can be designed for any specific analyzer upon request. Pack Size : 6 x 2 ml Principle Amylase test involves use of a chromogenic substrate Gal G, – a CNP (2-chloro-4-nitrophenyl linked with galactosyl maltoside). The direct action of amylase with this substrate results in the release of more than 90% of 2-chloro-4-nitrophenol, which can be monitored by kinetic assay at 405 nm. The increase in absorbance is directly proportional to the amylase activity in the sample. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details Mix thoroughly and transfer the assay mixture immediately to the thermostated cuvette and start the stopwatch simultaneously. Record the first reading at 60 second and subsequently three more readings with 30 seconds interval at 405 nm.

Send Message
product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 60 Diagnostic Reagent (Pack Size : 12 x 5 ml) from Accurex. Alkaline Phosphatase 60 are used in the diagnosis of hepatobiliary disorders and bone disease associated with increased osteoblastic activity. Alkaline Phosphatase high levels may be a sign of a liver problem or a bone disorder Alkaline Phosphatase 60 reagent is set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP), the reagent is a Highly stable reagent & its activity can be determined in just 2.5 minutes. About Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Pack Size : 12 x 5 ml Principle The working solution is stablə for 21 days at 2- 8°C. The working solution should be prepared and stored in the dark (working solution bottle) provided.This is critical because the reagent is light sensitive. It should therefore be kept away from direct light. Alkaline Phosphatase cleaves p-nitrophenyl phosphate (p-NPP) into p-nitrophenol and phosphate. p-nitrophenol is a yellow color compound in alkaline medium and absorbs light at 405 nm. The rate of increase in absorbance at 405 nm. is proportional to Alkaline phosphatase activity in specimen. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label. The working solutions of Non Prostatic Acid Phosphatase & Total Acid Phosphatases are stable for 7 days at 2-8°C.

Send Message
product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 300 Diagnostic Reagent from Accurex (Pack Size : 30 x 10 ml). Alkaline Phosphatase reagent is used for determination of Alkaline Phosphate activity based on kinetic method using p-nitrophenyl phosphate (p-NPP). Alkaline Phosphatase is a single reagent system using one step procedure & Alkaline Phosphatase activity can be determined in just 2.5 minutes & is is a Highly stable reagent. Alkaline Phosphatase cleaves p-nitrophenyl phosphate p- NPP in the presence of magnesium ions to form p nitrophenol & phosphate. About Method – p-NPP-DEA Buffer – Kinetic reaction with 60 seconds lag phase – Easy reconstitution : Tablet + Diluent – High liquid stability : 21 days Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphate activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Principle Alkaline Phosphatase cleaves p-nitrophenyl phosphate p- NPP) in the presence of magnesium ions to form p nitrophenol and phosphate. The intensity of the yellow color formed is directly proportional to the Application alkaline phosphatase activity in the specimen and measured kinetically. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details Two liquid reagent systems. Stable till the expiry date indicated on the label when stored in 2-8°C.

Send Message
product image
Clinical Chemistry

utozyme Albumin 300 Diagnostic Reagent from Accurex. Albumin 300 is used for determination of albumin in serum or plasma based on BCG method. Autozyme Albumin is a single reagent system which is ready to use, Albumin is linear up to 6 gm% & can be determined in 1 minute at room temperature. Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex. Albumin normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). About Autozyme Albumin is a reagent set for determination of albumin in serum or plasma based on BCG method Autozyme Albumin is a single reagent system, ready to use. Autozyme Albumin is linear up to 6 gm% Albumin can be determined in 1 minute at room temperature The shelf-life of Autozyme Albumin is 18 months Pack Size : 2 x 50 ml Principle Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex, The absorbance of this complex is proportional to the albumin concentration in serum or plasma. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and an abnormal commercial reference control serum,. it should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, cleanliness of glassware and accuracy of pipetting. Other Details The reagents are for in vitro diagnostic use. BCG reagent and standard should be stored at temperature indicated on the bottle label.

Send Message
product image
Clinical Chemistry

Autozyme Albumin 100 Diagnostic Reagent (Pack Size : 2 x 50 ml) from Accurex. Albumin reagent is used for determination of albumin in serum or plasma based on BCG method, can be determined in 1 minute at room temperature. BCG reagent and standard should be stored at temperature indicated on the bottle label. Accurex has gained considerable expertise in manufacturing & marketing of In-vitro Diagnostic reagents. Serum albumin in the presence of Bromocresol-green under acidic condition forms a green colored complex. Albumin normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). About Autozyme Albumin is a reagent set for determination of albumin in serum or plasma based on BCG method Autozyme Albumin is a single reagent system, ready to use. Autozyme Albumin is linear up to 6 gm% Albumin can be determined in 1 minute at room temperature The shelf-life of Autozyme Albumin is 18 months Pack Size : 2 x 50 ml Principle Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex, The absorbance of this complex is proportional to the albumin concentration in serum or plasma. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and an abnormal commercial reference control serum,. it should be realized that the uSe of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, cleanliness of glassware and accuracy of pipetting. Other Details The reagents are for in vitro diagnostic use. BCG reagent and standard should be stored at temperature indicated on the bottle label.

Send Message
product image
Clinical Chemistry

Infinite ADA 60 Diagnostic Reagent (R1 1 X 20ml: R2 1 X 10 ml) from Accurex. Infinite ADA reagent is used for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids. The Reagent is a ready-to-use two liquid reagent system & can be performed in 11 minutes at 37° C. ADA is also know as Adenosine Deaminase which eliminates a molecule called deoxyadenosine, which is generated when DNA is broken down. About Infinite ADA is a reagent set for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids. Infinite ADA is a ready-to-use, two liquid reagent system. With Infinite ADA, the assay is linear upto 200 U/L. Infinite ADA assay can be performed in 11 minutes at 37° C. Principle ADA catalyzes deamination of adenosine to inosine which is then converted to hypoxanthine by purine nucleoside phosphorylase (PNP). Hypoxanthine is then converted to uric acid and hydrogen peroxide (H2O2) by xanthine oxidase (XOD). H2O2 is further reacted with N-Ethyl-N-(2-hydroxy-3- sulfopropyl)-3-methylaniline (EHSPT) and 4-aminoantipyrine (4 AAP) in the presence of peroxidase (POD) to generate quinone dye. Quality Control To ensure adequate quality control, it is recommended that each laboratory should use a normal and an abnormal commercial reference control material. It should be realized that the use of quality control material checks both reagent and instrument functions together. Factors which might affect the performance of this test include instrument function, temperature control, cleanliness of glasswares and accuracy of pipetting. Other Details The reagents R1 & R2 are ready-to-use. The reagent kit should be stored at 2° – 8° C and is stable till the expiry date indicated on the label. Reagent R1 is light-sensitive & to be stored in dark. Contamination of the reagents should be strictly avoided.

Send Message
product image
Clinical Chemistry

Acid Phosphatase Diagnostic Reagent (Pack size: 8 x 1 ml) from Accurex. Acid Phosphatase is used in accordance with ISO 14189 to detect acid phosphatase from Clostridium perfringens. Autozyme Acid Phosphate reagent is set for determination of Acid Phosphatase activity based on Kinetic method using a-naphthyl phosphate. In acidic pH of the buffer system, the reagent hydrolyses a-naphthyl phosphate to a-naphthol & phosphate. Accurex has gained considerable expertise in manufacturing & marketing of In-vitro Diagnostic reagents. About Autozyme Acid Phosphate is a reagent set for determination of Acid Phosphatase activity based on Kinetic method using a-naphthyl phosphate Autozyme Acid Phosphate is a single reagent system using one step procedure Autozyme Acid Phosphate can be determined in just 8 minutes at 37 degree C Acid Phosphate can be used on any Spectrophotometer, Discrete semi automated and Automated Analyzer. Programme can be designed for any specific analyzer upon request. Pack Size : 8 x 1 ml Principle In acidic pH of the buffer system, Acid Phosphatase hydrolyses a-naphthyl phosphate to a-naphthol and phosphate. The o-naphthol is then coupled with Diazotized Fast Red TR to form a Diazo dye which has strong absorbance at 405 nm. The increase in absorbance is directly proportional to the level of acid phosphatase in serum. The addition of L-Tartrate inhibits prostatic acid phosphatase but does not inhibit other isoenzymes. The activity of Prostatic Acid Phosphatase is obtained by subtracting the result of Non prostatic Acid phosphatase (Determination with Tartrate) from Total Acid Phosphatase (without tartrate). Quality Control To ensure adequate quality control it is recommended that each batch should include a normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect ne performance of this test includes proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting.

Send Message
product image
Hematology

The advanced BC-6800Plus not only provides more reliable routine CBC plus 5-part DIFF results, but also has a higher throughput of up to 200 samples per hour. Based on the new SF Cube technology platform, the BC-6800Plus could provide more reliable blood cell results and abnormal cells flagging results with anticipated warning messages, exceeding clinicians’ expectations and setting a new standard for blood analysis. SF Cube Technology With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells, which is the key to revealing more abnormal cells. NRBC result in every CBC In WNB scattergram, BC-6800Plus provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6800Plus without extra reagent or cost. NLR parameter in each CBC+DIFF Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. More accurate RET and PLT-O result By utilizing the new fluorescent dye, the reticulocytes and platelets are more specific stained with stronger fluorescent signal, that brings more reliable reticulocyte and platelet results. Automatic Rerun & Reflex Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check. 200 test/hour BC-6800Plus can load up to 100 samples at a time and offers a throughput of up to 200 tests per hour.

Send Message
product image
Laboratory Testing Reagents

Product Description We are the Leading Supplier of Calibration Solution for pH TDS COND. The team of our skilled professionals is actively involved in providing a comprehensive array of Calibration Solution Salinity Cap. Our product is acclaimed in the industry owing to its purity & high effectiveness. This solution is processed under the direction of skilled professionals utilizing the optimum grade chemicals as per the set industry norms. Provided product is ideal for quickly performing the routine calibration required to maintain the robust performance of thermo scientific mass spectrometers. Features: Precise composition Longer shelf life Optimum quality Other Details: Calibration Solution for Salinity Cap - 480 ml, Range - 5 ppt, 25 ppt, 45 ppt CON603K Conductivity 0 to 200 m S/cm - Battery IP 54 Product Specification Usage Industrial Packaging Size 480 ml Grade Standard Reagent Grade Packaging Type Bottle Range 5 ppt, 25 ppt, 45 ppt Color Transparent Liquid

Send Message

Still searching for
reagent set?