Jaipur
+918529833535

'reagent pack'

Items tagged with 'reagent pack'

product image
Laboratory Testing Reagents

Orinasys (Orinasys B10,B10 Plus,4S,GP,GK) is a reagent strip for Urinalysis. Orinasys helps to ensure accurate measurements both visually and automatically. •Covers all the parameters necessary for urine testing. A maximum of 10 items can be measured simultaneously. •Choose the combination which best suits your testing needs. Orinasys (Orinasys B10,B10 Plus,4S,GP,GK) is a reagent strip for Urinalysis. Orinasys helps to ensure accurate measurements both visually and automatically. •Covers all the parameters necessary for urine testing.A maximum of 10 items can be measured simultaneously.•Choose the combination which best suits your testing needs.•Choice of visual measurement or automatic measurementon an exclusive analyzer •Choice of visual measurement or automatic measurement on an exclusive analyzer. Product Specification Number of Reactions(Preps)/Kit 10 Brand Orinasys Result Time (Rapid Kits) 1 min Sample Required Urin Shelf Life 24 Months Storage Instructions Store at room temperature Manufacturer Arkery Healthcare Pvt. Ltd/ Usage/Application Urinal Testing Packaging Type Box Minimum Order Quantity 2 Box

Send Message
product image
Clinical Chemistry

Superior Antisera based turbidimetry assays. Homogenized mixture makes antisera ideal for automation. Lesser Initial Absorbance ensures better sensitivity & linearity. Sl No Product Code Product Pack size (ml) 1 IHA101N HbA1C 1×30 2 IHJS HbA1C Standard 1×2/4×0.5 3 ICA101 CRP 1×44 4 TCJS CRP Standard 1×1 5 IRA101 RF 1×30 6 IRJS RF Standard 1×1 7 IMA101 MAU 1×44 8 IMJS MAU Standard 1×1 9 IAA101 ASO 1×44 10 IAJS ASO Standard 1×1 11 ICA102 Us CRP with Standard 1×10/2×25 12 IC3A102 C3 1×5/2×25 13 IC4A102 C4 1×5/2×25 14 IGAA102 IgA 1×5/2×25 15 IGGA102 IgG 1×5/2×25 16 IGMA102 IgM 1×5/2×25 17 IPJS Protein Standard High 1×1 18 ICH101 Immunology Control High 1×1 Information every single reagents has a diffrent price 1 pack single price.

Send Message
product image
Clinical Chemistry

Ready to use liquid stable reagents. Pack sizes cater to specific customer needs. High quality reagents manufactured to international standards. Categories: Clinical Chemistry, Reagents Description Reagents Technical Information KITS Albumin Alkaline Phosphatase AST/SGOT Bilirubin Direct Calcium CK-NAC Creatinine GGT LDL Direct Magnesium Total Protein Uric Acid ALT/SGPT Amylase Bilirubin Total Bilirubin Total & Direct Cholesterol CK-MB Glucose HDL Direct LDH-L Phosphorus Triglycerides Urea Kinetic (Rate BUN) Lipase information every single reagents has a diffrent price 1 pack single price.

Send Message
product image
Clinical Chemistry

Infinite Liquid a-Amylase 12 ml Diagnostic Reagent from Accurex (Pack Size : 6 x 2 ml). a-Amylase reagent is used for determination of amylase activity based on kinetic method using Gal G2 – a CNP. Amylase is a ready-to-use reagent. Normal amylase level is 40 to 140 units per liter (U/L) or 0.38 to 1.42 microkat/L (µkat/L). Infinite a-Amylase can be used on any Spectrophotometer, Discrete semiautomated & Automated analyzers. Reaction type is Kinetic. Accurex Biomedical is the first biochemical reagents manufacturing company in India About Infinite a-Amylase ‘is a reagent set for determination of amylase activity based on kinetic method using Gal G2 – a CNP. Infinite a-Amylase is a ready-to-use reagent. Infinite a-Amylase can be determined in just 21/2 minutes at 37°C. Infinite a-Amylase is linear upto 2000 IU/1. Infinite a-Amylase is a High Stability Reagent. Infinite a-Amylase can be used on any Spectrophotometer, Discrete semiautomated and Automated analyzers. Programme can be designed for any specific analyzer upon request. Pack Size : 6 x 2 ml Principle Amylase test involves use of a chromogenic substrate Gal G, – a CNP (2-chloro-4-nitrophenyl linked with galactosyl maltoside). The direct action of amylase with this substrate results in the release of more than 90% of 2-chloro-4-nitrophenol, which can be monitored by kinetic assay at 405 nm. The increase in absorbance is directly proportional to the amylase activity in the sample. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details Mix thoroughly and transfer the assay mixture immediately to the thermostated cuvette and start the stopwatch simultaneously. Record the first reading at 60 second and subsequently three more readings with 30 seconds interval at 405 nm.

Send Message
product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 60 Diagnostic Reagent (Pack Size : 12 x 5 ml) from Accurex. Alkaline Phosphatase 60 are used in the diagnosis of hepatobiliary disorders and bone disease associated with increased osteoblastic activity. Alkaline Phosphatase high levels may be a sign of a liver problem or a bone disorder Alkaline Phosphatase 60 reagent is set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP), the reagent is a Highly stable reagent & its activity can be determined in just 2.5 minutes. About Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Pack Size : 12 x 5 ml Principle The working solution is stablə for 21 days at 2- 8°C. The working solution should be prepared and stored in the dark (working solution bottle) provided.This is critical because the reagent is light sensitive. It should therefore be kept away from direct light. Alkaline Phosphatase cleaves p-nitrophenyl phosphate (p-NPP) into p-nitrophenol and phosphate. p-nitrophenol is a yellow color compound in alkaline medium and absorbs light at 405 nm. The rate of increase in absorbance at 405 nm. is proportional to Alkaline phosphatase activity in specimen. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label. The working solutions of Non Prostatic Acid Phosphatase & Total Acid Phosphatases are stable for 7 days at 2-8°C.

Send Message
product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 300 Diagnostic Reagent from Accurex (Pack Size : 30 x 10 ml). Alkaline Phosphatase reagent is used for determination of Alkaline Phosphate activity based on kinetic method using p-nitrophenyl phosphate (p-NPP). Alkaline Phosphatase is a single reagent system using one step procedure & Alkaline Phosphatase activity can be determined in just 2.5 minutes & is is a Highly stable reagent. Alkaline Phosphatase cleaves p-nitrophenyl phosphate p- NPP in the presence of magnesium ions to form p nitrophenol & phosphate. About Method – p-NPP-DEA Buffer – Kinetic reaction with 60 seconds lag phase – Easy reconstitution : Tablet + Diluent – High liquid stability : 21 days Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphate activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Principle Alkaline Phosphatase cleaves p-nitrophenyl phosphate p- NPP) in the presence of magnesium ions to form p nitrophenol and phosphate. The intensity of the yellow color formed is directly proportional to the Application alkaline phosphatase activity in the specimen and measured kinetically. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details Two liquid reagent systems. Stable till the expiry date indicated on the label when stored in 2-8°C.

Send Message
product image
Clinical Chemistry

utozyme Albumin 300 Diagnostic Reagent from Accurex. Albumin 300 is used for determination of albumin in serum or plasma based on BCG method. Autozyme Albumin is a single reagent system which is ready to use, Albumin is linear up to 6 gm% & can be determined in 1 minute at room temperature. Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex. Albumin normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). About Autozyme Albumin is a reagent set for determination of albumin in serum or plasma based on BCG method Autozyme Albumin is a single reagent system, ready to use. Autozyme Albumin is linear up to 6 gm% Albumin can be determined in 1 minute at room temperature The shelf-life of Autozyme Albumin is 18 months Pack Size : 2 x 50 ml Principle Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex, The absorbance of this complex is proportional to the albumin concentration in serum or plasma. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and an abnormal commercial reference control serum,. it should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, cleanliness of glassware and accuracy of pipetting. Other Details The reagents are for in vitro diagnostic use. BCG reagent and standard should be stored at temperature indicated on the bottle label.

Send Message

Still searching for
reagent pack?