Jaipur
+918529833535

'prior notice'

Items tagged with 'prior notice'

product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180T is a fully automated Glycohemoglobin analyzer based on HPLC (High Performance Liquid Chromatography) and is highly effective for ß-thalassemia testing. Measurement speed: 3.5 minutes/test Measurement Item as below HbA2 HbF HbA1c (Stable HbA1c, S-A1c), HbS, HbC, HbE and HbD can be detected. Column design with no more pre-filter change. Color LCD with reagent level, graphs on screen. Samples Whole blood or hemolysis sample Measurement items HbA1c(Stable HbA1c, S-A1c), HbA2 and HbF (HbS, HbC, HbE and HbD can be detected.) Reagents *1 ELUENT 80A, ELUENT 80B, ELUENT 80CT and HEMOLYSIS WASHING SOLUTION 80H Column *2 COLUMN UNIT 80T Measurement principle Reversed-phase cation exchange chromatography Detection method Dual-wavelength colorimetry (wavelengths measured: 420nm/500nm) Resolution 0.1% Ratio, 1 mmol/mol Measurement range *3 HbA1c : 3-20%, 9-195 mmol/mol HbA2 : 2-10% HbF : 0-100% Guaranteed measurement range *4 HbA1c : 4.2-12.9%, 22-117 mmol/mol HbA2 : 2.4-6.3% HbF : 0.1-14.3% Processing speed 210 seconds per sample Sample consumption Approx.14μL(whole blood) Sample container Blood collection tube (12.3 to 15mm diameter) × ( 75 to 100mm length) Sample cup(500μL) Sampling method Cap-Piercing Rack type ARKRAY racks Number of measurement samples One-way transportation (factory set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approx. 39℃ Display Color graphic LCD with backlight Memory capacity 500 test results ( including calibration results ) Built-in Printer Termal printer, 58mm thermal paper External output Serial 1 port (Can be optionally used as an Ethernet port.) Measurement conditions Temperature : 15-30℃ Humidity : 20-80% relative humidity (non-condensing ) Required sample volume Blood collection tube : Minimum 10mm away from the bottom Sample cup : 400μL or more Warm-up time Maximum 30 min. Dimensions 530(W)×530(D)×530(H)mm (Not including the hemolysis washing solution bottle) Weight Analyzer: Approx. 39kg, Sampler: Approx. 4kg Power supply AC100V-240V ±10% 50/60Hz Power consumption Max. 300 VA *1, *2 Reagents and column are sold separately from HA-8180T analyzer. *3 Error-free measurement ranges. *4 Guaranteed ranges for obtaining results equivalent to those from HA-8160 TP mode measurement. ※Design and specications may be changed without prior notice

Send Message
product image
Laboratory Usage

Using best-in-class technology, the Mindray CL-6000i is a chemiluminescence immunoassay analyzer with high throughput, high performance and high reliability. Features Throughput: up to 480 tests per hour Measurement principle: enhanced ALP-AMPPD method Reagent carousel: 36 reagent positions with non-stop refrigerating Sample handling: up to 300 samples can be loaded in one batch, sample loading and offloading continuously by sample racks, fast prioritizing STAT samples Sample volume: 5-110 μL Continuously loading of reagents, substrate, cuvettes, wash buffer and waste bags Zero daily maintenance Product Specification Model Name/Number CL-6000i Usage/Application Hospital Brand Mindray Sample Volume Range 5-110 microlitre Throughput up to 480 tests per hour Measurement Principle enhanced ALP-AMPPD method Reagent Carousel 36 reagent positions with non-stop refrigerating Sample Handling up to 300 samples can be loaded in one batch,sample loading and offloading continuously by sample r

Send Message
product image
Laboratory Testing Reagents

We are noticed amongst the well-known manufacturer and supplier in this domain, involved in providing Calibration Solution. This product is processed & formulated by our professionals utilizing superior grade chemicals in line with international quality norms. The offered product is obtainable in different grades with airtight packing in bottles as per the requirements of the clients. This product is tested at labs on numerous predefined standards of the industry before its final dispatch to the customers. Features: Safe usage Superior quality Easy to store Other Details: Calibration Solution Hamilton USA Make Ph / TDS / Cond / ORP / Redox in a Bottle of 500 ml NIST Traceable Certificate & 5 Year Shelf Life Product Details: Packaging Type Bottles Brand Hamilton Packaging Size 500 ml Color White Transparent Shelf Life 5 Years Certificate NIST Traceable

Send Message
product image
Glucometer

ONTOUR®PLUS ELITE blood glucose monitoring system. Discover high accuracy1 and ease of use - the features you want from a meter. Product Features High accuracy1 smartLIGHT® target range indicator Second-Chance® Sampling - 60 seconds Easy to use Connects to the free CONTOUR®DIABETES app** An Easy-To-Use System The features you want from a meter2. Easy to read: Big numbers on display. Easy to use: Large rubber buttons. No initial set up.* Personalized target ranges with averages on the meter. Discover smartLIGHT® for easier understanding of blood glucose levels3 The unique smartLIGHT® feature makes it quicker and easier to interpret blood glucose readings using coloured lights that clearly identify if the reading is above, within or below your target range.† Discover Second-Chance® sampling which may help save test strips4 CONTOUR®PLUS ELITE has a 60 second count down screen that provides patients the opportunity to apply more blood to the same strip if the first sample is insufficient. onnects to the free CONTOUR®DIABETES app The features you want from a meter2. Easy to read: Big numbers on display. Easy to use: Large rubber buttons. No initial set up.* Personalized target ranges with averages on the meter. The free CONTOUR DIABETES app is available to support diabetes self-management, adding insight and meaning to the results Easy to use: Syncs automatically with the meter to upload all blood glucose readings to an electronic diary Easy to understand: My Patterns helps identify trends in blood glucose results and displays notifications of potential causes Easy to share: The blood sugar diary report can be sent prior to, or shared during, an appointment with a healthcare professional The CONTOUR®DIABETES app applies appropriate safeguards to ensure your personal data is processed securely and in compliance with applicable laws.

Send Message
product image
Hemoglobin Meter

Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Operation Principle: The test strip utilizes Dry Chemistry Colorimeter Method (Azido methaemoglobin Method). When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors avtomatically measure the change in membrane reflectance. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Blood Sample Collection: Fresh or EDTA-anticoagulated capillary or venous whole blood may be used. If an EDTA – treated sample is refrigeratted to come to the room temperature before testing. EDTA treated blood samples should be mixed using end to and inversions at least 8 times prior to use, and should be tested within 24nours Do not use the haemolytic sample anticogulants other than EDTA are not recommended for use. Caution: 1. Same as all diagnostic tests, hemoglobin test results should be evaluated with the specific patient’s condition. Any results demonstrating the inconsistency with the patient’s clinical status should be repeated or supplemented with additional test data. 2. Do not touch the test membrane by hand 3. H12 Hemoglobin Test Strips are one-off product, do not use again Storage & Preparation: 1.H12 Hemoglobin Test Strips should be stored at O C-30 C dry and dark places, 2 C – B C is the best storage environment emperatures recommended. Keep away from direct sunlight and heat, must not be frozen, If the container was stored in refrigerated before first use, please don’t take it back into the refrigerator again after first use. 2. H12 Hemoglobin Test Strips are ready to use. No additional preparation is required 3. Enclosed desiccants with lest strip. Remove only those strips needed for testing. The remaining lest strips should be resealed in their onginal container and used up in 3 months after first use. Do not use lest strips and throw away alter expiry date. 4. Use the strip immediately once taking it out af the container, otherwise the result will be incorrect 5. Do not fold or cut the test strip. 6. Used lest strips cannot be used again, dispose them as normal medical waste Direction for Use Operating Instructions: 1. URIT Hemoglobin Meter, H12 Hemoglobin Test Strip, Lancing Device, and disposable blood taking needle. 2. Test steps: 1) Turn the meter on and input the Code Card. Check the Code Card displaying on the meter to ensure it to match the Code Card printed on the lest strip container. Otherwise, the result is incorrect. 2) Massage the patient’s finger from the knuckle up to the tip to stimulate blood flow. Clean the sample area with alcohol and wipe it dry with a sterile gauze pad. 3) Insert the lest strip into the strip holder with the notched end in first and the hole facing up. 4) Puncture the skin on the lower side of fingertip with blood collection needle, and remove 13-15 TIL of whole biood with capillary or other micro blood collection apparatus. While waiting for the instrument to display the blood drop symbol, quickly add the drops to the test hole on the reagent sheet. Please make sure that the blood drop volume can completely cover the test hole but not overflow the test hole. 5) The meter starts the test automatically after the blood sample disperses Once the lest is in process do nol disturb or move the meter or test strip, or press any key. The test result will display within 12 seconds. Qualtiy Control Procedure: Use only H12 Hemoglobin Test Strip with QC substance to perform QC. The range of QC substance is the numerical range indicated on the label of the QCsubstance or test strips. When to do a QCtest: 1. Whenever you suspect that the meter or test strips are not working properly. 2. If your hemoglobin test results are not consistent with how you feel. Other Info Limitations of test Method: H12 Hemoglobin Test Strip is only suitable for testing fresh or whole capillary blood or whole venous blood containing EDTA anticoagulants. Do not use serum, plasma or arterial blood

Send Message
product image
Rapid Test

Buy AccuTest COVID-19 IgG/IgM Rapid Test (Pack of 10 Tests) Online. COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. PRECAUTIONS & WARNING 1. This package insert must be read completely before performing thetest. Failuretofollow directions in insert may yield inaccurate test results. 2. Test results should be read between 10 and 15 minutes after aspecimenisapplied to the sample well. Results read after 20 minutes may giveerroneousresults.3. Do not open the sealed pouch until you are ready to conduct theassay.Onceopened, the cassettes should be used immediately. 4. Do not use expired devices. 5. Bring all reagents to room temperature (15-30°C) prior to use. 6. Do not mix components from different kits. Use only the buffer suppliedalongwith the kit. 7. Wear protective clothing and disposable gloves while handling thekit reagentsand clinical specimens. Wash hands thoroughly after performing thetest. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents arebeinghandled. 9. Dispose of all specimens and materials used to performthe test as biohazardouswaste. 10. Handle the negative and positive controls in the same manner as patientspecimens for operator protection. 11. Do not perform the test in a room with strong air flow, i.e. an electricfanorstrong air-conditioning. 12. Do not touch result window. 13. Use only for in-vitro diagnostic purpose.

Send Message
product image
Rapid Test

Buy AccuTest Syphilis Rapid Card Test (50 Tests) Online from Accurex. This Syphilis test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. Syphilis is caused by the bacterium Treponema pallidum. There different types of test like VDRL test, RPR test, FTA-ABS, etc. AccuTest Syphilis Test Kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity & specificity of 99.67%. Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. AccuTest Syphilis Rapid Test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. This kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity and specificity of 99.67%. 1. AccuTest Syphilis is a chromatographic immunoassay kit for rapid qualitative detection of Treponemal antibodies (IgA, IgM, IgG) generated against Treponema pallidum Antigens (17KDa, 15KDa, 47KDa) in human serum or plasma with high sensitivity and specificity. 2. Results just in 5-20 minutes 3. Accu Test Syphilis exhibits sensitivity and specificity of 99.67%. Features: Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. After the specimen is added to the specimen well in the device, it reacts with syphilis antigen coated particles in the test. The mixture migrates chromatographically along the length of the test strip and interacts with the immobilized syphilis antigen. The double antigen test format can detect IgA, IgG & IgM in specimens. If the specimen contains TP antibodies a coloured band will appear in the lest line region indicating a positive result. In the absence of TP antibodies a coloured band will not appear in the region indicating a negative result. To serve as a procedural control, a coloured band will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred. Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Direction for Use Procedure: 1. Bring the pouch to room temperature before opening to avoid condensation of moisture on the membrane of the device. Also bring the specimen to R.T. prior to testing. 2. Label the device with patient’s identification. 3. Add 2-3 drops (approx. 30 pl) of sample into the sample well of the test device. Avoid overflowing. 4. Wait for 5 – 20 minutes and read the result. It is important that the background is clear beforg the result is read. Note: Do not read the result after 30 minutes since specimen back flow may cause false result. STORAGE, STABILITY & HANDLING 1. The kit should be stored at 2 – 30° C. Do not freeze. 2. Do not use the kit past the expiration date stated on label. 3. Take off the device from the sealed pouch just before use as the device is sensitive to humidity and heat.

Send Message
product image
Rapid Test

Buy AccuTest HIV – 1/2 Ab Rapid Card Test (50 Tests) Online from Accurex. This Rapid HIV test is a visual, solid phase immunochromatographic assay for qualitative in-vitro diagnostic detection of antibodies against HIV-1 and HIV-2 in human serum/plasma. This HIV test may be used as an aid in diagnosis of HIV infection. In the HIV blood test – A reactive result should be confirmed by supplemental testing as part of a validated HIV testing algorithm. INTENDED USE: AccuTest HIV – 1/2 Ab test is a visual, solid phase immunochromatographic assay for qualitative in-vitro diagnostic detection of antibodies against HIV-1 and HIV-2 in human serum/plasma. The product may be used as an aid in diagnosis of HIV infection. A reactive result should be confirmed by supplemental testing as part of a validated HIV testing algorithm. INTRODUCTION: The Human Immunodeficiency Virus (HIV) is a retrovirus that infects cells of the immune system, destroying or impairing their function. The most advanced stage of HIV infection is Acquired Immunodeficiency Syndrome (AIDS). The general method of detecting infection with HIV is to observe the presence of antibodies to the virus by an EIA method followed by confirmation with any confirmation method. AccuTest HIV – 1/2 Ab is a simple, visual qualitative test that detects antibodies in human serum/plasma. The test is based on immunochromatography and can give a result within 15 minutes. PRINCIPLE: AccuTest HIV – 1/2 Ab employs chromatographic lateral flow device in a cassette format. Colloidal gold conjugated recombinant antigens (Au-Ag) corresponding to HIV-1 (gp120 + gp41) and HIV-2 (gp-36) are dry-immobilized at the end of nitrocellulose membrane strip. HIV-1 & HIV-2 antigens are bound at the Test Zone (1 & 2) respectively. Goat Anti-Mouse IgG antibodies are bound at the Control Zone(C). When the sample is added, it migrates by capillary diffusion rehydrating the gold conjugate. If there are HIV-1 or HIV-2 antibodies in sample, they will bind with the gold conjugated antigens forming particles. These particles will continue to migrate along the strip until the Test Zone (1 or 2) where they are captured by the HIV-1 or HIV-2 antigens generating a visible purple line. If the specimen contains antibodies to HIV-1, the specimen will bind to the 1 test line and produce line. If specimen contains antibodies to HIV2, the specimen will bind to the 2 test line. If there are no HIV-1 or HIV-2 antibodies in sample, no purple line is formed in the Test Zone. The gold conjugate will continue to migrate alone until it is captured in the Control Zone (C) by the Goat Anti Mouse IgG antibodies aggregating in a purple line, which indicates that the migration of liquid has been successful. The control line must be present for the test to be valid. PRECAUTIONS: 1. For best results, adhere to instructions provided. 2. All specimens should be handled as potentially infectious. 3. The test device is sensitive to humidity as well as heat. 4. Do not use beyond expiration date. 5. Do not use test kit if pouch is damaged or seal is broken. 6. Use test device immediately after removing from the pouch. 7. The components (test device and assay diluents) in this kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 8. The AccuTest HIV – 1/2 Ab Test devices should be stored at 4 to 30 °C. Do not expose the kit to temperature over 30 °C. 9. Specimen with extremely high concentrations of red blood cells, fibrin should be recentrifuged before use. 10. AccuTest HIV – 1/2 Ab Test Device (Serum/Plasma) is for in vitro diagnostic use only. 11. AccuTest HIV – 1/2 Ab Test Device (Serum/Plasma) will only indicate the presence of antibodies to HIV-1/2 in the specimen and should not be used as the sole criteria for the diagnosis of HIV-1, HIV-2, and/or HIV-1 subtype O infection. 12. For confirmation of reactive test results, specimens should undergo further testing using different assays, such as rapid diagnostic tests, EIA and/or Western blotting in accordance with a validated HIV testing algorithm. 13. As with all diagnostic tests, all results must be interpreted together with other clinical information available to the physician. 14. Results should not be used to determine the serotype of HIV infections TEST PROCEDURE: 1. Allow the test device, buffer and specimen to reach room temperature (15-30 °C) prior to testing. 2. Remove the test device from the foil pouch and use the test device as soon as possible (within one hour). 3. Place the device on a flat, dry surface. Label with specimen ID. 4. Holding the sample dropper vertically above the test disk, slowly transfer 1 drop (10µl) of sample in to the sample well, then add 2 drops of assay diluent (about 75 µl) and start the timer. 5. As the test begins to work, you will see purple color moving across the result Window in the center of the Test Disk. 6. Wait for the colored lines to appear. Interpret test results at 15 to 20 minutes. Do not interpret test result after 20 minutes. STORAGE AND STABILITY Store as packaged in the sealed pouch at 4-30 °C (storage in refrigerator is permitted). Do not store in the freezer. Protect the test kit from humidly. The test device is stable until the expiration date printed on the test kit and/or sealed test device pouch. Do not use beyond the expiration date. The test device must remain in the sealed pouch until use.

Send Message
product image
Rapid Test

Buy AccuTest HCV Rapid Card Test (30 Tests) Online from Accurex. HCV means Hepatitis C Virus which is a is a small, enveloped, positive-sense, single-stranded RNA virus. Hepatitis C symptoms are fever, fatigue, decreased appetite, nausea, vomiting, abdominal pain, dark urine, pale feces, joint pain and jaundice. HCV test is a rapid Chromatographic Immunoassay work on principle of the double antigen sandwich technique, Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. AccuTest HCV Test is a rapid Chromatographic Immunoassay for the Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. Hepatitis C Virus (HCV) is a small, enveloped, positive-sense, single-stranded RNA virus. Antibody to HCV is found in over 80% of patients with well documented non-A, non-B hepatitis. Conventional methods fail to isolate the virus in cell culture or visualize it by electron microscope. Cloning the viral genome has made it possible to develop serologic assays that use recombinant antigen, multiple antigens using recombinant protein and/or synthetic peptides have been added in new serologic tests to avoid nonspecific cross-reactivity to increase the sensitivity of HCV antibody tests. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or quest Principle: AccuTest HCV Rapid Hepatitis C Virus Test (Serum/Plasma/Whole Blood) is a lateral flow chromatographic immunoassay based on the principle of the double antigen-sandwich technique. The membrane is coated with recombinant HCV antigen on the test line region of the device. During testing, the serum/plasma or W.Blood specimen reacts with HCV antigen coated particles. The mixture migrates upward on the membrane chromatographically by capillary action to react with recombinant HCV antigen or membrane and generate a colored line. Presence of this colored line indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear at the control line region, indicating that the correct volume of specimen has been added and membrane wicking has occurred. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Safety Information •Positive: If a distinct purple line is formed at the test one marked ‘T’ (Test Line) and the Control Zone marked ‘C’ (Control Line) the test result is positive, indicating the sample contains Hepatitis C antibody. The interpretation of test results (+ve for hepatitis) remains unchanged even if there is a difference in intensity of color in positive line and control line as is many a time found. •Negative: If a distinct purple line is formed only at the control zone marked ‘C’ (control line) the test result is negative • Invalid: A total absence of color in both © and (T) regions or no colored band appears on the control © region is an indication of procedure error and/or the test reagent has deteriorated. Repeat with a new test kit. Direction for Use Test Procedure 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Other Info Storage and Stability AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch.

Send Message

Still searching for
prior notice?