Jaipur
+918529833535

'precise test method'

Items tagged with 'precise test method'

product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite hCG Combo Rapid Test is a lateral flow chromatographic immunoassay for the early detection of pregnancy, by providing a quick direct visual test for the placental hormone, hCG in human serum, plasma and urine. It can be performed within 5-10 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite hCG Combo Rapid Test is not intended for quantitative results, nor for over the counter (OTC) sales. It is intended to meet all requirements for yielding rapid, easily read, qualitative results for the purpose of early pregnancy detection via assay of hCG, a placental hormone that may be present in human serum, plasma or urine. The hCG detection limit the OnSite hCG Combo Rapid Test is 12.5 mIU/mL in serum or plasma specimen, and 25 mIU/mL in urine specimen. It is designed for professional use only, and provides only preliminary analytical data. For a final diagnosis of pregnancy, a more specific alternative clinical method must be used to obtain a confirmed analytical result. Clinical accuracy: In comparison with a reference chemiluminecsence or ELISA, hCG detection is 100% sensitivity and 100% specificity in urine specimens 100% sensitivity and 99.5% specificity in serum specimens Analytical sensitivity: 100% positive detection rate at 12.5 mIU/mL in serum/plasma specimens and 100% positive detection rate at 25 mIU/mL in urine specimens Analytical specificity: no cross reactivity with 1,000 mIU/mL human luteinizing hormone (hLH), 1,000 mIU/mL human follicle stimulating hormone (hFSH), and 1,000 mIU/mL human thyroid stimulating hormone (hTSH) Dose hook effect: no dose hook effect was observed for hCG at concentrations up to 500,000 mIU/mL in urine specimens Interference: No interference was seen with 35 biological and chemical analytes commonly found in OTC, prescriptions or abuse drugs in urine or serum/plasma specimens, as well as pH 4-9 (see detail in the package insert) Shelf life: 24 month Kit box package: 1. Individually sealed foil pouches containing; a. One dip strip device b. One desiccant 2. One package insert (instruction for use) Tube package: 1. Strip Package 2. One desiccant 3. One package insert (instruction for use) CTK Products at a Glance Drugs.com: Overview of Human Chorionic Gonadotropin Inserts

Send Message
product image
Rapid Test

The OnSite HBV-5 Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of hepatitis B surface antigen (HBsAg), hepatitis B surface antibody (HBsAb), hepatitis B e-antigen (HBeAg), hepatitis B e-antibody (HBeAb), and hepatitis B core antibody (HBcAb) in human serum or plasma. It is intended to be used by healthcare professionals to aid in the diagnosis of infection with hepatitis B virus (HBV). Any use or interpretation of this preliminary test result must also rely on other clinical findings and the professional judgment of healthcare providers. Alternative test method(s) should be considered to confirm the test results obtained by this device. Panel format cassette to conveniently test for five targets at once Utilize all markers to help distinguish between acute and chronic infections Result in 15 minutes Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Package insert (instruction for use) CTK Products at a Glance Inserts Poster U.S. CDC: hepatitis B Virus FAQs for Health Professionals WHO: Health Topic for Hepatitis

Send Message
product image
Rapid Test

The OnSite hCG Combo Rapid Test is a lateral flow chromatographic immunoassay for the early detection of pregnancy, by providing a quick direct visual test for the placental hormone, hCG in human serum, plasma and urine. It can be performed within 5-10 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite hCG Combo Rapid Test is not intended for quantitative results, nor for over the counter (OTC) sales. It is intended to meet all requirements for yielding rapid, easily read, qualitative results for the purpose of early pregnancy detection via assay of hCG, a placental hormone that may be present in human serum, plasma or urine. The hCG detection limit of the OnSite hCG Combo Rapid Test is 12.5 mIU/mL in serum or plasma specimen, and 25 mIU/mL in urine specimen. It is designed for professional use only, and provides only preliminary analytical data. For a final diagnosis of pregnancy, a more specific alternative clinical method must be used to obtain a confirmed analytical result. Clinical accuracy: In comparison with a reference chemiluminecsence or ELISA, hCG detection is 100% sensitivity and 100% specificity in urine specimens 100% sensitivity and 99.1% specificity in serum specimens Analytical sensitivity: 100% positive detection rate at 12.5 mIU/mL in serum/plasma specimens and 100% positive detection rate at 25 mIU/mL in urine specimens Analytical specificity: no cross reactivity with 1,000 mIU/mL human luteinizing hormone (hLH), 1,000 mIU/mL human follicle stimulating hormone (hFSH), and 1,000 mIU/mL human thyroid stimulating hormone (hTSH) Dose hook effect: no dose hook effect was observed for hCG at concentrations up to 500,000 mIU/mL in urine specimens Interference: No interference was seen with 35 biological and chemical analytes commonly found in OTC, prescriptions or abuse drugs in urine or serum/plasma specimens, as well as pH 4-9 (see detail in the package insert) Shelf life: 24 month Individually sealed foil pouches containi a. One cassette device b. One plastic dropper c. One desiccant One package insert (instruction for use) CTK Products at a Glance Drugs.com: Overview of Human Chorionic Gonadotropin Inserts CATALOG # PRODUCT QUANTITY SPECIMEN R1001C hCG Combo Rapid Test CE 30/kit S/Urine OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT QUANTITY SPECIMEN R1001S hCG Combo Rapid Test (Strip) CE 50/kit, 100/kit S/Urine

Send Message
product image
Rapid Test

The OnSite Duo HSV-1/2 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) and herpes simplex virus 2 (HSV-2) in human serum, plasma or whole blood. This test can be performed in 10 minutes by minimally skilled personnel without the use of laboratory equipment. This test is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with HSV-1 and/or HSV-2. The OnSite Duo HSV-1/2 IgG/IgM Rapid Test uses HSV-1 glycoprotein G1 and HSV-2 glycoprotein G2 for the specific detection and differentiation of IgG and IgM antibodies to HSV-1 and HSV-2 in serum, plasma and whole blood. An HSV-1 and/or HSV-2 IgM positive result indicates an active infection, which may be primary or recurrent. An HSV-1 and/or HSV-2 IgG positive result indicates a recent or past infection. However, a negative test result does not preclude the possibility of infection with HSV-1 and/or HSV-2. Any interpretation or use of this preliminary test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Alternative test method(s) should be considered to confirm the test result obtained by this device. Clinical accuracy: 90.6% sensitivity and 91.4% specificity for anti-HSV-1 IgG detection 93.8% sensitivity and 96.0% specificity for anti-HSV-2 IgG detection 85.0% overall agreement for anti-HSV-1 IgM detection comparing to commercial ELISA 100% overall agreement for anti-HSV-2 IgM detection comparing to BBI Panel (PTH202) Positive rate on random clinical specimens:8% for IgG anti-HSV-1 and 4.9% for IgM anti-HSV-1 (n=10,000); 4.6% for anti-HSV-2 IgG and 1.7% for anti-HSV-2 IgM Cross reactivity: no cross reactivity with the following disease states or special conditions, respectively: palladium, H. pylori, Dengue, Malaria, Typhoid, Toxoplasma, Rubella, CMV, hCG, TB, HAV, HBV, HCV, HEV, HIV, ANA, HAMA, RF (up to 1,000 IU/mL) Interference: No interference was seen with Albumin 60 g/L , Hemoglobin 2 g/L, Bilirubin 20 mg/dL, Heparin 3,000 U/L, Creatinine 442 µmol/L, Salicylic acid 4.24 mmol/L, EDTA 3.4 µmol/L, Sodium citrate 8%, Glucose 55 mmol/L Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use)

Send Message
product image
Instruments

The new and improved RTR-1 uses an image processing method. During measurement, the lateral flow device is captured using a 5-mega pixel camera and the picture is analyzed using image processing algorithms for identification of either presence or absence of test line bands or test line band intensity levels. The reader converts the image into a grayscale and then classifies the intensity levels of the image in 0 to 255 grayscale range. The image processing algorithm undergoes various levels of filtering and segmentation to yield the correct intensity levels from the picture. Based on the preconfigured intensity levels, the reader classifies the band intensity and reads out the results as either positive or negative. ACCURACY: Less than 3% intra-run CV Eliminates subjective interpretation by operator FLEXIBILITY: Single mode for low volume test setting Batch mode allows for high volume test setting Result output as semi-quantitative line intensity and visual image EASE-OF-USE: Built in barcode reader provides faster test setup Touch screen interface for easy operation Lightweight (0.7kg) and portable DATA MANAGEMENT: Results presented on screen, on a printout or uploaded to reader database Storage capacity of 1,000 test results (including images) Laboratory Information System (LIS) and Wi-Fi compatible Human Machine Interface 4-inch resistive touch screen Camera 5 mega pixel CMOS camera Barcode Scanner Integrated 1 dimensional barcode scanner Printer 48 mm inbuilt thermal printer Mode Single mode and batch mode operations Port/USB Data export and software upgrade through 2 USB ports Storage Storage capacity of 1000 test results (including images) Result output “Positive or Negative” as well as quantitative test line intensity Power 12V 2A Processor ARM Cortex-A53 Platform Embedded Linux Dimension 220 mm X 170 mm X 110 mm (L x B x H) Weight 0.7 kg (Approx CATALOG # PRODUCT RTR-1 Rapid Test Reader OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT ADX-110 ELISA Reader ADX-120 Microplate Washer

Send Message
product image
Instruments

CLIAlyzer is an intuitive bench-top chemiluminescent analyzer allowing for quick operation and use. CLIAlyzer delivers results when paired with our RapidLight tests. Laboratories can run multiple specimen options and six tests simultaneously, providing up to 24 test results per hour. The CLIAlyzer is an in vitro diagnostic device used for the quantitative determination of concentrations of various analytes found in serum, whole blood, or plasma specimens. Compact size Automated walkaway system Easy operation with 7-inch touchscreen Barcode reader reduces manual entry errors Results on screen, on a printout, or uploaded to database Storage capacity of 100,000 test results Laboratory Information System (LIS) connectivity High accuracy and precision with highly sensitive PMT for signal detection Assay results as quick as 15 minutes (test-specific) Compatibility with whole blood, serum, plasma (test-specific) Six cartridge positions Automatic detection of test parameter through barcode on test strip, thus reducing any user-related errors Low maintenance analyzer due to no storage of buffer System: Automated chemiluminescence system Interface: 7-inch color touch screen Methodology: Magnetic particle-based assay with chemiluminescence detection Reaction mode: Batch mode Sample type: Serum, plasma, whole blood (test specific) Sample positions: 6 Volume: 420mm x 610mm x 321mm Weight: 35kg Connectivity: USB, RS232, LIS connection Barcode Scanner: 1-D & 2-D barcode

Send Message

Still searching for
precise test method?