Jaipur
+918529833535

'practice'

Items tagged with 'practice'

product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
BP Apparatus

Reckoned enterprises in this domain, we are immersed in providing an impeccable Eye Tonometer. Presented Eye Tonometer is processed under the supervision of knowledgeable personnel as par the preset industry principles and guidelines. We offer this Eye Tonometer in several specifications as per the requisites of customers. Our respected client can acquire this product at most competitive rate from us. Apart from this, these are developed after specifically understanding the varying necessities and desires of our customers to retain their perfection and efficiency. Features: High performance Low maintenance Quality tested Product Details: Usage Laboratory Brand Swastik Type Eye Tonometer Measurement capacity 0-20 divisions Presentation In practice kit including testblock and weights Precision +/- 0.3

Send Message
product image
Rapid Test

Buy AccuTest Vitamin D Rapid Card Test (10 Tests) Online from Accurex. The Vitamin D test kit consists of 25 AccuTest Vitamin D individually packed test, devices in foil pouches, 25 pipettes for collecting 10 ul of whole blood, 25 lancets, 1 Buffer Vial (Buffer 5 mL) with stabilizers and, thimerosal, 1 Package Insert. Vitamin D Fast test kit is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This Vitamin D test provides a preliminary screening test result. INTENDED USE AccuTest Vitamin D is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This assay provides only a preliminary screening test result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. The performance characteristics of this assay have not been established in a pediatric population. PRINCIPLE AccuTest Vitamin D is based on the principle of a competitive enzyme immunoassay. The assay is based on the competition for 25-OH Vitamin D present in blood/serum sample and Vitamin D present on the test line for fixed number of antibody-gold conjugate. Depending upon the concentration of Vitamin D in blood/serum, there will be free antibody-gold conjugate molecules that will bind to Vitamin D on the test strip and will show a colored line in the test line zone. A control line is present in the test window to work as procedural control. PRECAUTIONS 1. For in vitro diagnostic use only. 2. The test is designed for use with human blood/serum only. 3. Reagents must be at room temperature (8⁰C – 30 ⁰C). 4. Do not use if test device packaging is open or damaged. 5. Do not use the product beyond expiration date. 6. Handle all specimens as potentially infectious. Proper handling and disposal methods should be used according to good laboratory practices. 7. Read test results for 10 minutes as required. Results may deteriorate and may not be consistent after 10 minutes. 8. In order to avoid variable results, mix the blood sample thoroughly. 9. A serum sample subjected to repeated freeze thaw cycles may give variable results Direction for Use PROCEDURE 1. Remove the cassette from the sealed pouch and place it on a hard flat surface with the view window facing up (use the cassette as soon as possible). 2. Using a micropipette, add 10 µl of whole blood or 5ul of serum sample directly into the rectangular specimen well (marked with Red drop) of the cassette. 3. Add 3 full drops of Buffer into the square buffer well of the cassette (Do not move the cassette after addition of buffer). 4. Let the cassette sit for 10 minutes and read your results immediately. Results may deteriorate after the 10 minute mark. Other Info STORAGE AND STABILITY The test device should be stored at 8 ⁰C – 30 ⁰C and will be stable until the expiration date stated on the package. The product is humidity sensitive and should be used immediately after being open. INTERPRETATION OF RESULTS Match the color of the test line with the chart provided.

Send Message
product image
Hematology

Product Specification Model ABX Micros 60 Screen 2 lines of 40 alphanumerical characters. Dimensions 16.5 in x 14 x 12.5 in Weight 31 lbs Power Supply 90/240 V - 50/60 Hz - 230 VA Printer Laser Printer Stability 24 hours (CBC) Graphics LMG histogram,RBC,PLT histograms Minimum Order Quantity 1 Product Description We are a leading entity, occupied in presenting a wide range of ABX Micros 60 Hematology Analyzer. Furthermore, our customers can avail these products from us at reasonable prices. Other Details: Most reliable 3-DIFF analyzer. This device is ideal for medical practices, emergency laboratories, or also as a backup. The Micros 60 also comes as an "open"- or "closed"-tube version.

Send Message

Still searching for
practice?