Jaipur
+918529833535

'potential biological risk'

Items tagged with 'potential biological risk'

product image
Glycohemoglobin Analysis

Xpress A1c strips are used for a testing of quantitative determination of glycated hemoglobin(HBA1c) in human whole blood. It is used to monitor metabolic control in diabetic patients. it helps in diagnosis of the diabetes or pre-diabetes in adults. Buy Xpress A1c strips online (Pack of 25 Strips) – the best a1c test strips from Point of Care (POC) Range of Accurex HbA1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. The Xpress A1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. The Xpress A1c strips then needs to be inserted into Xpress A1c meter for hemoglobin measurement, The Xpress A1c meter measures the absorbance of whole blood at Hb isosbestic point. Xpress A1c meter uses two wavelengths of light to calculate Hemoglobin level, user level calibration is not required. How to use: Step 1: Wash hands using soap and warm water. Rinse and dry thoroughly. Step 2: Turn on the meter by pressing-releasing the power button. Step 3: Remove an Xpress A1c strip from the vial. Step 4: Prick a finger to obtain a blood sample. Step 5: Touch and hold the drop of blood to the pointed edge of the Xpress A1c strip. The blood is drawn into the Xpress A1c strip by capillary action Step 6: Once the blood fills the Xpress A1c strip chamber. Insert the Xpress A1c strip into the Xpress A1c meter. Step 7: Your Hemoglobin result will appear on the display window. Step 8: Remove the Xpress A1c strip from the meter and discard it. The meter will automatically turn off or long-press the power button to turn off. The Xpress A1c strips are used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. is used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes.Features: Sample Type: Whole Blood/EDTA Blood/Capillary Blood Measuring Range: 0 to 25 g/dl Temperature: 0°C-50°C Storage Temperature: Room Temperature Expiry: Long Expiry(min 02 yrs) Pack Size: 25 Test/Vial LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message
product image
Glycohemoglobin Analysis

Accurex Xpress A1c Glycohemoglobin Analysis System Kit . The Kit contains HbA1c Meter, 1 Sampler, 1 box of 25 test strips, Buffer A, Buffer B. Glycohemoglobin Analyzer It is used for testing glycohemoglobin concentration as an aid to monitor the risk of developing diabetes & control the status of diabetes. Buy Xpress A1c Meter Kit Online from Accurex Point of Care (POC ) Range – The HbA1c analyzer is specifically designed to be used with the corresponding test strip. HbA1c analyzer Hemoglobin A1C is a common blood test that measures blood glucose levels over the past two to three months. •Glycohemoglobin Analyzer •Handheld HbA1c Meter •Battery Operated •No Pipetting, No Lysing •Lab like Accuracy •Battery Operated •Truly Portable •Voice prompt for •User Guidance • Accurate result with cv <3% •Lab like accuracy with 95% •No interference of HB Variant •No pipetting •No lysing •Reagent: Suitable to store at room temperature (upto 30º C) The Power of HbA1c in your Hand esting Principle: Boronate Affinity Chromatography Testing Parameter: Glycohemoglobin (HbA1c) Measuring Range: 4.0% – 14.0% Precision: CV <3% (HbA1c: 4.0% – 6.5%) Blood Sample: Finger Prick or Venous Blood ( EDTA Anticoagulant) Blood Volume: About 3ul Testing Time: About 5 minutes Data Unit: Set in Advance the Data Unit • NGSP%; IFCC mmol/mol; eAG* mmol/l Voice Prompt: Voice Prompt to Guide the user Data Storage: 1000 Testing Data Data Port: Mini USB data interface can be connected with HIS/LIS; System Thermal Printer Power Required: AAA Battery x 4 Analyzer Dimension: 61.6 x 122.9 x 24.5 mm Screen Size: 47 x 32 mm” Safety Information LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Other Info Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message
product image
Rapid Test

Intended Use The 4th Generation HIV TRI-DOT + Ag test is a visual, rapid, sensitive and accurate immunoassay for the differential detection of HIV-1 p24 antigen and HIV-1 & HIV-2 antibodies (IgM,IgG & IgA) in Human Serum or Plasma. The test is a screening test for p24 antigen (HIV-1), anti-HIV-1 & anti-HIV-2 and is for in vitro diagnostic use only. It is intended for screening of blood donors or other individuals at risk for HIV-1 & HIV-2 infection and for clinical diagnostic testing. Salient Features Rapid visual test ,based on enzyme immuno assay & Flow Through Technology. Rapid test for simultaneous and differential detection of p24 Antigen & antibodies for HIV on the same device. Ideal for Blood screening: detects sero-negative HIV Cases. Use of gp-41, C terminus of gp120 for HIV-1 antibodies & gp-36 for HIV -2 antibodies. Detection of Group ‘0’ & subtype ‘C’ of HIV-1, which is most prevalent in India. Unique washing steps for clear Interpretation of Results. Evaluated by National Institute of Biologicals- 100 % Sensitivity & 100 % Specificity. Long Shelf life: 15 months at 2-8° C.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Cys C Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Cys C in human whole blood, serum or plasma. This test is used as an aid to predict the risk of developing chronic kidney disease. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ BNP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Brain Natriuretic Peptides (BNP) in human whole blood or plasma. This test is used as an aid to predict the risk of heart failure. STORAGE AND STABILITY 1. Store the test kit at 4 ℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Rapid Test

Intended Use HIV Ag & Ab Card (4th Generation) is a visual, rapid qualitative and sensitive solid phase immunochromatographic assay for the differential detection of HIV-1 p24 Antigen and Antibodies (IgM, IgG & IgA) to HIV-1& HIV-2 in Human Serum/ Plasma/ Whole blood (collected by venipuncture or Fingerprick). The test is a screening test for p24 antigen (HIV-1) and HIV antibodies (anti-HIV-1 & anti-HIV-2) and is for in vitro diagnostic use only. It is intended for screening of blood donors or other individuals at risk for HIV-1 & HIV-2 infection and for clinical diagnostic testing. It is a screening test for p24 antigen (HIV-1) and HIV antibodies (anti-HIV-1 & anti-HIV-2). The test is for in vitro diagnostic use only and is intended for screening of blood donors or others individuals at risk for HIV-1 and/or HIV-2 infection and for clinical diagnostic testing. Salient Features • Finger prick, rapid, visual and qualitative Immunoassay. • 4TH Generation Rapid test for differential detection of p24 Antigen & antibodies for HIV in serum/plasma /whole blood. • Ideal for Blood screening, detects sero-negative HIV Cases. • Use of gp-41, C terminus of gp120 for HIV-1 , gp-36 for HIV -2 antibodies and Anti-p24 for HIV p24 Ag detection. • Detection of Group ‘0’ & subtype ‘C’ of HIV-1, which is most prevalent in India. • Based on Immunochromatography Technique. • See through device for easy interpretation of results. • Sensitivity : 100 % & Specificity: 100% • Analytical Sensitivity of HIV p24 Ag : 100 IU/ml (traceable to p24 Antigen NIBSC Standard, U.K. Code No. 90/636) • Long Shelf life 30 months at 2-30°C • Convenient pack size: 25 T.

Send Message
product image
Clinical Chemistry

ADVIA Chemistry XPT System An advanced, automated clinical chemistry analyzer for high-volume laboratories The ADVIA® Chemistry XPT System provides timely, reliable results with continuous operation to meet the chemistry workloads of the most demanding laboratories. Delivers high throughput of up to 2400 tests per hour. Manages comprehensive testing with a menu of more than 115 assays. Improves workflow using automation and system technologies such as micro-volume and aliquot retention. Features & Benefits The ADVIA Chemistry XPT System*** is engineered for continuous operation and timely, accurate results—supporting you to reach your full potential today and be prepared for tomorrow. With an advanced user interface that is easy to use and VeriSmart Technology to support accuracy of testing, the ADVIA Chemistry XPT System predictably and consistently delivers timely, reliable results to meet expanding workloads. Simplified, Continuous Operation Simplify operation and training with the intuitive, icon-driven user interface. Extend walkaway times with concentrated reagents that provide high test capacity onboard. Quickly load most system fluids on the fly. Automate calibration, QC, startup, and shutdown. Consistent, Predictable Turnaround Time and Accuracy Offer a comprehensive chemistry menu of over 115 assays, including general and specialty chemistry, DAT, TDM, and specific proteins. Push productivity with a throughput of up to 2400 tests per hour (1800 photometric, plus 600 ISE). Control testing: STAT and specialty samples can always be front-loaded while an automation track is running. Designed for Automation Adapt and grow with direct connectivity to Siemens Healthineers and . Simplify your laboratory operations with connectivity to IT solutions including , , and . Increase productivity and efficiency with direct-from-track sampling and onboard aliquoting that allows samples to be immediately released to the next workstation. Do More with Less Reduce blood-draw requirements with micro-volume technology that uses a single 30 μL sample for up to 15 tests. Eliminate sample callback with automated, pre-programmable dilution, reflex, and rerun testing that uses an onboard aliquot. Improve workflow and accuracy with VeriSmart echnologies that perform hardware and software checks at all stages of sample processing.

Send Message
product image
Medical Equipment

Brand new BeneHeart D60 has made a major breakthrough for the industry. The multi-talent D60 integrating 12-lead ECG and POCUS, gives strong boost for on-site diagnosis. The first ever int-ext dual-factor evaluation system with closed-loop rescue approach combining resuscitation, debriefing, and training, supports continuous improvement of the rescue quality. With full touch screen and key hard buttons allowing for quick and neat control, BeneHeart D60 effectively expands rescue potential and makes rescuers more confident. Smart Touch, More Intuitive With advanced high-definition capacitive touch screen technology and flat UI design, D60 brings a clearer visual experience and more smooth operation feelings, making efficiency at your fingertips. First 9” display with 1200 x 1020 resolution Auto-brightness Gesture-control touchscreen Keep physical knob and buttons for key operations With the intelligent sensing, you can operate D60 normally, even if - the screen is spilled with liquid - wearing up to 5 layers of gloves All in one-360J Manual defib /AED /Pacing /Monitoring: ECG, SPO2, NIBP, CO2 Ultra-light Only 4.2kg (with battery) for exceptional portability Versatile paddles-External paddles with contact indicator improve usability for clinicians Visual AlarmSight™ Problem-solving support with graphical visualization One Device with Multi-talent

Send Message

Still searching for
potential biological risk?