Jaipur
+918529833535

'position hand'

Items tagged with 'position hand'

product image
Digital Spectrophotometer

Product Details: Application Laboratory Accuracy 0.001 g Position Hand Held Make Japan, Brix Material Steel, Rubber Type Portable We are the leading of Coolant Hand Refractometers. Salinity Refractometer, ERMA, Japan Make, Range: 0-28%, Range: 0-100% Hand Refractometer Model D, for urine, Serum / Protein, ERMA JAPAN make Model : D Refractometer for battery/ coolants, ERMA Japan Gem Refractometer Digital portable refractometer imported Make Brix : 0-45%, Refractive Index Range : 1.3330 to 1.7000 Digital portable refractometer imported Make Brix : 0-95%, Refractive Index Range : 1.4098 to 1.5318 nD, Salinity : 0-30% U.S.A Salinity meter, Digital (Table Model), 3 1/2 Digit LED Display with Salinity Cell & Other Accessories Digital specific gravity salinity meter Temperature Meter, Model DSG - 10 Range : Specific Gravity : 1.000 - 1.030, Salinity (PPT) : 5 ppt to 40 ppt, Temp : 0ºC - 100ºC Digital salinity TDS Temperature Meter, Model: HDS 1024, Imported Make Range : Salinity : 0.00 - 5.00 % Salt, TDS : 0-999 ppm mg/L, Temperature : 0ºC to 100ºC

Send Message
product image
Laboratory Usage

Using best-in-class technology, the Mindray CL-6000i is a chemiluminescence immunoassay analyzer with high throughput, high performance and high reliability. Features Throughput: up to 480 tests per hour Measurement principle: enhanced ALP-AMPPD method Reagent carousel: 36 reagent positions with non-stop refrigerating Sample handling: up to 300 samples can be loaded in one batch, sample loading and offloading continuously by sample racks, fast prioritizing STAT samples Sample volume: 5-110 μL Continuously loading of reagents, substrate, cuvettes, wash buffer and waste bags Zero daily maintenance Product Specification Model Name/Number CL-6000i Usage/Application Hospital Brand Mindray Sample Volume Range 5-110 microlitre Throughput up to 480 tests per hour Measurement Principle enhanced ALP-AMPPD method Reagent Carousel 36 reagent positions with non-stop refrigerating Sample Handling up to 300 samples can be loaded in one batch,sample loading and offloading continuously by sample r

Send Message
product image
Laboratory Usage

TACHOMETER/STROBOSCOPE, Model : BP-2259 ( 2 in 1, DIGITAL PHOTO TACHOMETER with DIGITAL STROBOSCOPE ) FEATURES* Intelligent, microprocessor circuit design, high accuracy, wide range, digital readout.* One instrument include two functions of " Digital Photo Tachometer " & " Digital Stroboscope "* Digital Stroboscope :Wide setting range from 100 RPM to 100,000 RPM, digital display with high accuracy. Modern solid state high visible orange light, long life, almost maintenance free. It is ideal for inspectingand measuring the speed of moving gears, fans, centrifuges, pumps, motors and other equipment used in general industrial maintenance, production, quality control, laboratories and as well as for schools and colleges for demonstrating strobe action.* Digital Photo Tachometer :No contact RPM measurement, wide measuring range from 0.5 to 100,000 RPM. 0.1 RPM resolution for the measured value < 1000 RPM. The last value, max., value, min. value can be stored into the memory automatically & be obtained by pressing " Memory Call Button ". High visible LCD display gives RPM reading exactly with no guessing or errors.* The use of durable, long lasting components, including a strong, light weight ABS plastic housing.Cabinet has been carefully shaped to fit comfortable in either hand. GENERAL SPECIFICATIONS Display 5 digits, 10 mm ( 0.4" ) LCD Operation 0 - 50 (32 - 122 ). ( Liquid Crystal display ) with Temperature function annunciation. Operating Less than 80% RH.Accuracy ± ( 0.1 % + 2 digit ). Humidity Sampling Time 1 second ( 60 RPM ). Size 215 x 65 x 38 mm.Time base:Quartz crystal. (8.5 x 2.6 x 1.5 inch). Circuit Exclusive one-chip design Weight 300g(0.66 LB)/including battery.microprocessor LSI circuit. Accessories : Carrying case ................... 1 PC.Battery 4 x 1.5V AA ( UM-3 ) battery. Operation manual ..............1 PC.ELECTRICAL SPECIFICATIONS ( PHOTO TACHOMETER )Measurement Range 5 to 99,999 RPM Resolution 0.1 RPM ( < 1,000 RPM ) 1 RPM ( 1,000 RPM )Photo Tach. detecting distance 50 to 150 mm/2 to 6 inch. * Typical max. 300 mm/12 inch depending upon ambient light.ELECTRICAL SPECIFICATIONS ( STROBOSCOPE )Stroboscopic 100 to 100,000 FPM/RPM Flash tube High efficiency orange LED Flash Rate FPM: flash per minute lamp.RPM : round per minute Flash Duration Approximately 60 to 1,000Flash Adjust 3 ranges : microseconds. Range Range A: 100-1,000 FPM Flash color Orange Range B: 1,000-10,000 FPM Flash Duration Approx. 16% of period time. Range C: 10,000-100,000 FPM Flash Adjust Coarse adjust knob and Resolution 0.1 FPM/RPM. Knob Fine adjust knob.(Less than 1,000 FPM/RPM) Calibration Crystal time base and1 FPM/RPM microprocessor circuit, don't(Over 1,000 FPM/RPM) necessary take any external calibration process. OPERATIONS PROCEDURES ( STROBOSCOPE )Preparation Determine the range switch to " 1000 RPM " ," 10,000 RPM " or" 100,000 RPM " position.Checking When checking speed, care must be taken to insure that the strobe is flashing in Speed unison (one to one) with the object being monitored. A Stroboscope will also stop motion at 2:1, 3:1, 4:1 et., this is normally referred to as harmonies. To be sure of unison, turn the dial until two images appear - this will double the actual speed. Then lower the flashing rate until a single and stationary image appears -this is the actual true speed.Checking For motion analysis, simply locate the actual speed as mentioned above and then Motion turn the dial slowly up or down. This will give a slow motion effect allowing complete inspection.

Send Message
product image
Laboratory Usage

We are the Leading Supplier of Hand Sugar Refractometer. Hand Sugar Refractometer is developed for working with sugar related liquids (fruit juice, soft-drinks, wine, honey), help monitor to control sugar concentrations in foods and beverages. Checking the “ripeness” of fruit in the field, verifying product quality after harvesting or controlling concentrations during processing and packaging, refractometers provide critical information to ensure product quality. And the model RHB-10, RHB-18 and RHB-32 are also commonly used for controlling the concentration of various industrial fluids (cutting lubricants and flux rinsing compounds). Model Range Min.Div. Accuracy Remark RHB-10 Brix: 0-10% Brix: 0.1% Brix: ±0.10% ATC RHB-18 Brix: 0-18% Brix: 0.1% Brix: ±0.10% ATC RHB-32 Brix: 0-32% Brix: 0.2% Brix: ±0.20% ATC RHB-55 Brix: 0-55% ATC RHB-62 Brix: 28-62% Brix: 0.2% Brix: ±0.20% ATC RHB-82 Brix: 45-82% Brix: 0.5% Brix: ±0.50% ATC Brix: 58-92% Brix: 0.5% Brix: ±0.50% RHB-92 Baume: 38-43Be' Baume: 0.5Be' Baume: ±0.50Be' ATC water: 12-27% water: 1% water: ±1%

Send Message
product image
Rapid Test

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 10 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % Safety Information Important saftey handling: • Wash hands thoroughly, with soap and water before and after testing • Never use fingerstick devices for more than one person. Use auto disabling, single use fingerstick devices for assisted monitoring of blood glucose. Storage & Handling: • Store the strips in their original vial in a cool, dry place between: 0°-50° C (32° and 122° F). Keep away from direct sunlight and heat. • Do not refrigerate or freeze. • When you take a strip from the vial, close the cap immediately. Use the strip immediately. • Check the expiry date on the vial. If the expiry date has passed, do not use the strips. Important health-related information: • Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult your physician or doctor immediately. • Test results below 70 mg/dL. mean low blood glucose (hypoglycemia). • Test results greater than 180 mg/dL mean high blood glucose (hyperglycemia). • If you get results below 70 mg/dL or above 180 mg/dL and do not have symptoms of hypoglycemia or hyperglycemia, repeat the test. If you have symptoms or continue to get results that fall below 70 mg/dL or above 180 mg/dL, follow the treatment/advice of your healthcare professional. • If you are experiencing symptoms that are not consistent with your blood glucose test and you have followed all instructions described in the Xpress Gluco owner’s booklet, consult your healthcare professional Other Info UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Glycohemoglobin Analysis

Xpress A1c strips are used for a testing of quantitative determination of glycated hemoglobin(HBA1c) in human whole blood. It is used to monitor metabolic control in diabetic patients. it helps in diagnosis of the diabetes or pre-diabetes in adults. Buy Xpress A1c strips online (Pack of 25 Strips) – the best a1c test strips from Point of Care (POC) Range of Accurex HbA1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. The Xpress A1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. The Xpress A1c strips then needs to be inserted into Xpress A1c meter for hemoglobin measurement, The Xpress A1c meter measures the absorbance of whole blood at Hb isosbestic point. Xpress A1c meter uses two wavelengths of light to calculate Hemoglobin level, user level calibration is not required. How to use: Step 1: Wash hands using soap and warm water. Rinse and dry thoroughly. Step 2: Turn on the meter by pressing-releasing the power button. Step 3: Remove an Xpress A1c strip from the vial. Step 4: Prick a finger to obtain a blood sample. Step 5: Touch and hold the drop of blood to the pointed edge of the Xpress A1c strip. The blood is drawn into the Xpress A1c strip by capillary action Step 6: Once the blood fills the Xpress A1c strip chamber. Insert the Xpress A1c strip into the Xpress A1c meter. Step 7: Your Hemoglobin result will appear on the display window. Step 8: Remove the Xpress A1c strip from the meter and discard it. The meter will automatically turn off or long-press the power button to turn off. The Xpress A1c strips are used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. is used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes.Features: Sample Type: Whole Blood/EDTA Blood/Capillary Blood Measuring Range: 0 to 25 g/dl Temperature: 0°C-50°C Storage Temperature: Room Temperature Expiry: Long Expiry(min 02 yrs) Pack Size: 25 Test/Vial LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message
product image
Glycohemoglobin Analysis

Accurex Xpress A1c Glycohemoglobin Analysis System Kit . The Kit contains HbA1c Meter, 1 Sampler, 1 box of 25 test strips, Buffer A, Buffer B. Glycohemoglobin Analyzer It is used for testing glycohemoglobin concentration as an aid to monitor the risk of developing diabetes & control the status of diabetes. Buy Xpress A1c Meter Kit Online from Accurex Point of Care (POC ) Range – The HbA1c analyzer is specifically designed to be used with the corresponding test strip. HbA1c analyzer Hemoglobin A1C is a common blood test that measures blood glucose levels over the past two to three months. •Glycohemoglobin Analyzer •Handheld HbA1c Meter •Battery Operated •No Pipetting, No Lysing •Lab like Accuracy •Battery Operated •Truly Portable •Voice prompt for •User Guidance • Accurate result with cv <3% •Lab like accuracy with 95% •No interference of HB Variant •No pipetting •No lysing •Reagent: Suitable to store at room temperature (upto 30º C) The Power of HbA1c in your Hand esting Principle: Boronate Affinity Chromatography Testing Parameter: Glycohemoglobin (HbA1c) Measuring Range: 4.0% – 14.0% Precision: CV <3% (HbA1c: 4.0% – 6.5%) Blood Sample: Finger Prick or Venous Blood ( EDTA Anticoagulant) Blood Volume: About 3ul Testing Time: About 5 minutes Data Unit: Set in Advance the Data Unit • NGSP%; IFCC mmol/mol; eAG* mmol/l Voice Prompt: Voice Prompt to Guide the user Data Storage: 1000 Testing Data Data Port: Mini USB data interface can be connected with HIS/LIS; System Thermal Printer Power Required: AAA Battery x 4 Analyzer Dimension: 61.6 x 122.9 x 24.5 mm Screen Size: 47 x 32 mm” Safety Information LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Other Info Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message
product image
Diabetes

Product Features: Better precision, CV < 2.5 % Patented CLE technology enables complete elimination of labile glycohemoglobin ensuring accurate HbA1c results. HbA1c test results in 3.5 minutes with HbA2/HbF flagging. Separation of hemoglobin fractions Complete removal of labile fraction up to 10% No interference of HbF up to 10% No interference of lipemia or icterus, can run on non-fasting patient samples HbA1c reportability presence of HbS, HbC, HbD and HbE Compact bench top model User friendly touch screen operation Sampling from multiple sized primary tubes, including microcapillary collection tubes On board QC functions with Levey-Jennings and statistical calculations Unlimited storage of calibration, QC data and chromatograms No sample preparation required Simple reagent and column replacement Automated maintenance RFID reagent identification and tracking Automatic barcode identification of samples NGSP certified Calibrators and Controls IFCC traceable Complete kit with buffers, calibrator and column Product Application: Hba1c Testing Sampler Handler: 10 Position Rack Loader, positive identification by internal barcode reader Sample Type: Whole blood on EDTA K3 or K2 anticoagulant Haemolysate from EDTA whole blood samples Time for Analysis: Throughput approximately 3.5 minutes between samples Interferences: Complete removal (not separation) of labile up to 10% Sampling System: Sample Aspiration Probe coupled with a high precision, Sample Aspiration Volume: 14.5 µl in whole blood, 670 µl in lysate mode. Pump: 2 high pressure syringe pumps Detector Type: UV-Vis Reagent Traceability: RFID Printer: Built- in thermal printer with possibility to connect to external printer

Send Message

Still searching for
position hand?