Jaipur
+918529833535

'plasma equivalent results'

Items tagged with 'plasma equivalent results'

product image
Glycohemoglobin Analysis

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 100 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Rapid Test

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 10 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % Safety Information Important saftey handling: • Wash hands thoroughly, with soap and water before and after testing • Never use fingerstick devices for more than one person. Use auto disabling, single use fingerstick devices for assisted monitoring of blood glucose. Storage & Handling: • Store the strips in their original vial in a cool, dry place between: 0°-50° C (32° and 122° F). Keep away from direct sunlight and heat. • Do not refrigerate or freeze. • When you take a strip from the vial, close the cap immediately. Use the strip immediately. • Check the expiry date on the vial. If the expiry date has passed, do not use the strips. Important health-related information: • Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult your physician or doctor immediately. • Test results below 70 mg/dL. mean low blood glucose (hypoglycemia). • Test results greater than 180 mg/dL mean high blood glucose (hyperglycemia). • If you get results below 70 mg/dL or above 180 mg/dL and do not have symptoms of hypoglycemia or hyperglycemia, repeat the test. If you have symptoms or continue to get results that fall below 70 mg/dL or above 180 mg/dL, follow the treatment/advice of your healthcare professional. • If you are experiencing symptoms that are not consistent with your blood glucose test and you have followed all instructions described in the Xpress Gluco owner’s booklet, consult your healthcare professional Other Info UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Critical Care

Product Description: Medica Corporation’s EasyLyte® analyzer is a completely automated, microprocessor-controlled electrolyte system that uses ISE (Ion Selective Electrode) technology to make electrolyte measurements. The EasyLyte measures combinations of Na+, K+, in whole blood, serum, plasma, or urine. EasyLyte incorporates state-of-the-art electronics and an innovative ergonomic design that differentiates it significantly from competitors. The analyzer also stores quality-control data that is easily accessible. Patient histories are immediately retrievable for evaluation. EasyLyte analyzers combine simple yes/no prompted operation, low maintenance, and high reliability into one economical design. Product Features: EasyLyte is Easy to Use, Easy to Operate, Easy to Maintain The entire menu is driven by 2 simple buttons Results are displayed on LCD screen as well as printouts EasyLyte does 2 point as well as 1 point calibration Facility to analyze different type of samples: whole blood, serum, plasma ,urine samples EasyLyte has capillary and syringe sampling facility EasyLyte has auto probe wiping facility Analysis of electrolytes is done using 100ul of blood and 400ul of diluted urine Rate of analysis 55 secs per sample Analyzer is capable of storing 128 patients data with trilevel QC results Analyzer has modular plug in reagent pack system EasyLyte has facility for auto calibrations with a programmed interval of 4 hrs and also calibration on demand Analyzer has facility to upgrade to a walk away Electrolyte station by use of Auto Sampler It has a built in thermal printer and a RS 232 port for interfacing Product Applications: Sodium - Na, Potassium - K CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg) Reagents used with this 'EasyLyte' CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg)

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Vitamin D Rapid Quantitative Test along with Finecare™ FIA Meter is a fluorescence immunoassay quantitative determination of total 25(OH) D2/D3 level in human serum or plasma. Results are to be used in conjunction with other clinical and laboratory data to assist the clinician in the assessment of vitamin D sufficiency. STORAGE AND STABILITY 1. Store at 4°C~30°C up to the expiration date. 2. The solid marker bottle can be stored at 2°C~8°C for 28 days after being reconstituted. 3. Do not remove the device from the pouch until ready to use. The Test Cartridges should be used within 1 hour once opened.

Send Message
product image
Immunoassay Reagents

INTENDED USE The Finecare™ 2019-nCoV lgM/lgG Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for qualitative detection of IgG and IgM antibodies of novel coronaviruses (2019-nCoV) in human whole blood, serum and plasma specimen. Clinically, the test is to be used as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by 2019-nCoV. The test provides preliminary test results. Negative results cannot exclude the possibility of 2019-nCoV infection and they cannot be used as the sole basis for treatment or other management decision. STORAGE AND STABILITY 1. Store at 4-30°C in the sealed pouch up to the expiration date printed on the package. Do not freeze. 2. The test device should be used within 1 hour after taking out from the foil envelope. 3. Keep away from sunlight, moisture and heat. 4. Kit contents are stable until the expiration date printed on the outer box.

Send Message
product image

Intended Use The 4th Generation HCV TRI-DOT is a rapid, visual, sensitive and qualitative in vitro diagnostic test for the detection of (IgM,IgG & IgA) antibodies to Hepatitis C virus in human serum or plasma. It has been developed and designed with increased sensitivity for core and NS3 antibodies using a unique combination of modified HCV antigen. Salient Features Based on “Flow Through Technology”, which is similar to Elisa technology because of involvement of washing steps at various levels to enhance the specificity. Use of highly purified HCV antigens for Core, NS3, NS4, NS5 immobilized on the device. Detection of all the subtypes of HCV. Results within 3 minutes. In built quality control dot which validates the test. 100% Sensitivity & 98.9% Specificity as per WHO evaluation. Shelf life : 24 months at 2-8°C

Send Message
product image
Rapid Test

Intended Use Diagnos Dengue card is a rapid solid phase Immuno-chromatographic test for the qualitative differential detection of IgM and IgG antibodies to dengue virus in Human serum /Plasma. This test is for in vitro diagnostic use only and is intended as an aid in for presumptive diagnosis between primary and secondary dengue infection. Salient Features Rapid, visual and qualitative Immunoassay. Differential detection of IgM & IgG Antibodies. Detection of all the 4 Dengue serotypes (DEN-1, DEN-2, DEN-3 and DEN-4). See through device for easy interpretation of results. Unique sample processing method ensures highest accuracy in results. Results with in 20 minutes. Longer shelf life : 30 months at 2-30°C. Convenient pack size : 10 tests Sensitivity-95% and Specificity- 97%. Principle

Send Message

Still searching for
plasma equivalent results?