Jaipur
+918529833535

'physician'

Items tagged with 'physician'

product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message
product image
Rapid Test

Buy AccuTest HIV – 1/2 Ab Rapid Card Test (50 Tests) Online from Accurex. This Rapid HIV test is a visual, solid phase immunochromatographic assay for qualitative in-vitro diagnostic detection of antibodies against HIV-1 and HIV-2 in human serum/plasma. This HIV test may be used as an aid in diagnosis of HIV infection. In the HIV blood test – A reactive result should be confirmed by supplemental testing as part of a validated HIV testing algorithm. INTENDED USE: AccuTest HIV – 1/2 Ab test is a visual, solid phase immunochromatographic assay for qualitative in-vitro diagnostic detection of antibodies against HIV-1 and HIV-2 in human serum/plasma. The product may be used as an aid in diagnosis of HIV infection. A reactive result should be confirmed by supplemental testing as part of a validated HIV testing algorithm. INTRODUCTION: The Human Immunodeficiency Virus (HIV) is a retrovirus that infects cells of the immune system, destroying or impairing their function. The most advanced stage of HIV infection is Acquired Immunodeficiency Syndrome (AIDS). The general method of detecting infection with HIV is to observe the presence of antibodies to the virus by an EIA method followed by confirmation with any confirmation method. AccuTest HIV – 1/2 Ab is a simple, visual qualitative test that detects antibodies in human serum/plasma. The test is based on immunochromatography and can give a result within 15 minutes. PRINCIPLE: AccuTest HIV – 1/2 Ab employs chromatographic lateral flow device in a cassette format. Colloidal gold conjugated recombinant antigens (Au-Ag) corresponding to HIV-1 (gp120 + gp41) and HIV-2 (gp-36) are dry-immobilized at the end of nitrocellulose membrane strip. HIV-1 & HIV-2 antigens are bound at the Test Zone (1 & 2) respectively. Goat Anti-Mouse IgG antibodies are bound at the Control Zone(C). When the sample is added, it migrates by capillary diffusion rehydrating the gold conjugate. If there are HIV-1 or HIV-2 antibodies in sample, they will bind with the gold conjugated antigens forming particles. These particles will continue to migrate along the strip until the Test Zone (1 or 2) where they are captured by the HIV-1 or HIV-2 antigens generating a visible purple line. If the specimen contains antibodies to HIV-1, the specimen will bind to the 1 test line and produce line. If specimen contains antibodies to HIV2, the specimen will bind to the 2 test line. If there are no HIV-1 or HIV-2 antibodies in sample, no purple line is formed in the Test Zone. The gold conjugate will continue to migrate alone until it is captured in the Control Zone (C) by the Goat Anti Mouse IgG antibodies aggregating in a purple line, which indicates that the migration of liquid has been successful. The control line must be present for the test to be valid. PRECAUTIONS: 1. For best results, adhere to instructions provided. 2. All specimens should be handled as potentially infectious. 3. The test device is sensitive to humidity as well as heat. 4. Do not use beyond expiration date. 5. Do not use test kit if pouch is damaged or seal is broken. 6. Use test device immediately after removing from the pouch. 7. The components (test device and assay diluents) in this kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 8. The AccuTest HIV – 1/2 Ab Test devices should be stored at 4 to 30 °C. Do not expose the kit to temperature over 30 °C. 9. Specimen with extremely high concentrations of red blood cells, fibrin should be recentrifuged before use. 10. AccuTest HIV – 1/2 Ab Test Device (Serum/Plasma) is for in vitro diagnostic use only. 11. AccuTest HIV – 1/2 Ab Test Device (Serum/Plasma) will only indicate the presence of antibodies to HIV-1/2 in the specimen and should not be used as the sole criteria for the diagnosis of HIV-1, HIV-2, and/or HIV-1 subtype O infection. 12. For confirmation of reactive test results, specimens should undergo further testing using different assays, such as rapid diagnostic tests, EIA and/or Western blotting in accordance with a validated HIV testing algorithm. 13. As with all diagnostic tests, all results must be interpreted together with other clinical information available to the physician. 14. Results should not be used to determine the serotype of HIV infections TEST PROCEDURE: 1. Allow the test device, buffer and specimen to reach room temperature (15-30 °C) prior to testing. 2. Remove the test device from the foil pouch and use the test device as soon as possible (within one hour). 3. Place the device on a flat, dry surface. Label with specimen ID. 4. Holding the sample dropper vertically above the test disk, slowly transfer 1 drop (10µl) of sample in to the sample well, then add 2 drops of assay diluent (about 75 µl) and start the timer. 5. As the test begins to work, you will see purple color moving across the result Window in the center of the Test Disk. 6. Wait for the colored lines to appear. Interpret test results at 15 to 20 minutes. Do not interpret test result after 20 minutes. STORAGE AND STABILITY Store as packaged in the sealed pouch at 4-30 °C (storage in refrigerator is permitted). Do not store in the freezer. Protect the test kit from humidly. The test device is stable until the expiration date printed on the test kit and/or sealed test device pouch. Do not use beyond the expiration date. The test device must remain in the sealed pouch until use.

Send Message
product image
Rapid Test

Buy AccuTest H Pylori AB Rapid Card Test (50 Tests) Online from Accurex. The Helicobacter Pylori is a lateral flow chromatographic immunoassay for the qualitative detection of antibodies to H.pylori in human Whole Blood/Serum/Plasma. H Pylori test provides an aid in the diagnosis of infection with H.pylori. H.pylori is implicated in the etiology of a variety of gastrointestinal diseases, including duodenal and gastric ulcer, non-ulcer dyspepsia and active and chronic gastritis. h pylori symptoms are an ache or burning pain in your stomach (abdomen), Nausea, Loss of appetite, Frequent burping, Bloating & Unintentional weight loss NTENDED USE The H.pylori Antibody Rapid Test Card is a lateral flow chromatographic immunoassay for the qualitative detection of antibodies to H.pylori in human Whole Blood/Serum/Plasma. It provides an aid in the diagnosis of infection with H.pylori. INTRODUCTION H.pylori is implicated in the etiology of a variety of gastrointestinal diseases, including duodenal and gastric ulcer, non-ulcer dyspepsia and active and chronic gastritis. H.pylori infection is found in more than 90% of duodenal ulcer patients and in around 75% of all peptic ulcer sufferers. H.pylori infection is also more common in gastric cancer patients. The risk of gastric cancer has been estimated to be six-fold higher in H.pylori infected populations than in uninfected populations. H.pylori infections occur in human populations throughout the world. In developed countries, about 50% of the population may have H.pylori infection by the age of 60 years, while only 10-20% of adults in the third decade of life have it. Transmission is most probably by the fecal-oral or oral-oral route. Both invasive and non-invasive methods are used to diagnose H.pylori infection in patients with symptoms of gastrointestinal disease. Invasive methods include culture of gastric biopsy samples, histologic examination of stained biopsy specimens, or direct detection of the urease activity in the biopsy (CLO test). These methods need to obtain a biopsy sample by endoscopy.which is expensive,and usually results discomfort and risk to the patient.noninasive techniques include urea breath tests and serological methods. Urea breath test requires expensive laboratory equipment and moderate radiation exposure. Serologic tests are employed to detect antibodies as human immune response to H.pylori, for example the ELISA and the Western immunoblot. The H.pylori Antibody Rapid Test Card detect antibodies to H.pylori infection in human Whole Blood/Serum/Plasma. It is a noninvasive method and does not use radioactive isotopes. The test is easy to perform and requires no specialized equipment. Visual interpretation provides an accurate qualitative result. It is a useful on-site aid in the diagnosis of H.pylori infection. Diagnosis of H.pylori infection by antibody immunoassay can reduce the number of patients requiring endoscopy. PRINCIPLE The H.pylori Antibody Rapid Test Card is an immunoassay based on the principle of the double antigen-sandwich technique. During testing, a Whole Blood/Serum/Plasma specimen migrates upward by capillary action. The antibodies to H.pylori if present in the specimen will bind to the H.pylori conjugates. The immune complex is then captured on the membrane by the pre-coated H.pylori antigens, and a visible pink-purple line will show up in the test line region indicating a positive result. If antibodies to H.pylori are not present or are present below the detectable level, a pink-purple line will not form in the test line region indicating a negative result. To serve as a procedural control, a pink-purple line will always appear at the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred. Safety Information The H.pylori Antibody Rapid Test Card is limited to provide a qualitative detection. The intensity of the test line does not necessarily correlate to the concentration of the antibody in the blood. x The results obtained from this test are intended to be an aid in diagnosis only. Each physician must interpret the results in conjunction with the patient’s history, physical findings, and other diagnostic procedures. x A negative test result indicates that antibodies to H.pylori are either not present or at levels undetectable by the test. Direction for Use TEST PROCEDURE 1. Remove the test cassette from the sealed pouch and use it as soon as possible. 2. Place the test cassette on a clean and level surface. 3. For serum or plasma specimen: Hold the dropper vertically and transfer 3 drops of serum or plasma to the specimen well (S) of the test cassette, then start the timer. See illustration below. 4. For whole blood specimens: Hold the dropper vertically and transfer 1 drop of whole blood (approximately 30μl) to the specimen well(S) of the test cassette, then add 2 drops of buffer (approximately 70μl) and start the timer. 5. Read results at 15 minutes. Do not interpret the result after 20 minutes. Other Info STORAGE AND STABILITY x Store as packaged in the sealed pouch at 4-40℃. The kit is stable within the expiration date printed on the label. x Once open the pouch, the test should be used within one hour. Prolonged exposure to hot and humid environment will cause product deterioration.

Send Message
product image
Glycohemoglobin Analysis

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 100 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Rapid Test

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 10 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % Safety Information Important saftey handling: • Wash hands thoroughly, with soap and water before and after testing • Never use fingerstick devices for more than one person. Use auto disabling, single use fingerstick devices for assisted monitoring of blood glucose. Storage & Handling: • Store the strips in their original vial in a cool, dry place between: 0°-50° C (32° and 122° F). Keep away from direct sunlight and heat. • Do not refrigerate or freeze. • When you take a strip from the vial, close the cap immediately. Use the strip immediately. • Check the expiry date on the vial. If the expiry date has passed, do not use the strips. Important health-related information: • Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult your physician or doctor immediately. • Test results below 70 mg/dL. mean low blood glucose (hypoglycemia). • Test results greater than 180 mg/dL mean high blood glucose (hyperglycemia). • If you get results below 70 mg/dL or above 180 mg/dL and do not have symptoms of hypoglycemia or hyperglycemia, repeat the test. If you have symptoms or continue to get results that fall below 70 mg/dL or above 180 mg/dL, follow the treatment/advice of your healthcare professional. • If you are experiencing symptoms that are not consistent with your blood glucose test and you have followed all instructions described in the Xpress Gluco owner’s booklet, consult your healthcare professional Other Info UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Gluco + Test Strips (Pack of 50 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips require a sample volume of 0.5 μL and taking just 5 seconds to return a test result. XPRESSGLUCO+ strips make the testing experience superior. These Glucometer strips are for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh Accurex Blood Glucose test strips provide accurate results in just 5 seconds. XPRESSGLUCO+ Blood Glucose Test Strips are used with the XPRESSGLUCO+ Blood Glucose Meters. They are intended for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh. They are for testing outside the body (in vitro diagnostic use only). Donot use them for diagnosis of diabetes or testing on neonates. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Safety Information • Discard used test strips and lancets responsibly according to your local regulations. • Keep test strips vial away from children. A child could choke on the test strips. The test strips and their vial contain agents that may be harmful if swallowed. If they are swallowed, promptly see a doctor for immediate assistance. Do not change medication based on the test results without the advice of a physician or healthcare professional. Direction for Use • Prior to first use, ensure that the package is undamaged and closed. • Keep the test strip vial away from sunlight and in a cool, dry place between 5 – 40°C (41 – 104°F). Do not freeze it. • Store test strips in their original pack only. Do not put the test strips in any other container. • Use test strips immediately after removing from the package. • Do not use test strips after the expiration date. • Avoid getting dirt, food or water on the test strip. Do not handle test strips with wet hands. All parts of the test strip should be touched only with dry and clean fingers. • Do not perform blood glucose tests at a temperature below +10°C (50°F) or above +40°C (104°F), or above 85% relative humidity Other Info Each test strip is plasma-calibrated†, requiring a sample volume of 0.5 μL and taking just 5 seconds to return a test result. The test range is 20 to 600 mg/dL (or 1.1 to 33.3 mmol/L) with resolution at 1 mg/dL (0.1 mmol/L). †Plasma-calibrated: Test results produced on capillary whole blood samples by XPRESSGLUCO+ System are compared with the results of the corresponding plasma samples tested by the YSI 2300 Glucose Analyzer, calibrated by YSI 2747 Glucose Standard (a NIST traceable glucose standard). The margin of error of the YSI 2300 Glucose Analyzer measurement is 0.289 mg/dL when the blood glucose concentration is higher than 100 mg/dL, or 0.029 mg/dL when the blood glucose concentration is lower than 100 mg/dL. (1 mmol/L= 18 mg/dL).

Send Message
product image
Glycohemoglobin Analysis

XPRESSGLUCO+ strips make the testing experience superior. These Glucometer strips are for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco + Test Strips (Pack of 100 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips require a sample volume of 0.5 μL and taking just 5 seconds to return a test result. XPRESSGLUCO+ Blood Glucose Test Strips are used with the XPRESSGLUCO+ Blood Glucose Meters. They are intended for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh. They are for testing outside the body (in vitro diagnostic use only). Donot use them for diagnosis of diabetes or testing on neonates. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Safety Information • Discard used test strips and lancets responsibly according to your local regulations. • Keep test strips vial away from children. A child could choke on the test strips. The test strips and their vial contain agents that may be harmful if swallowed. If they are swallowed, promptly see a doctor for immediate assistance. Do not change medication based on the test results without the advice of a physician or healthcare professional. Other Info Each test strip is plasma-calibrated†, requiring a sample volume of 0.5 μL and taking just 5 seconds to return a test result. The test range is 20 to 600 mg/dL (or 1.1 to 33.3 mmol/L) with resolution at 1 mg/dL (0.1 mmol/L). †Plasma-calibrated: Test results produced on capillary whole blood samples by XPRESSGLUCO+ System are compared with the results of the corresponding plasma samples tested by the YSI 2300 Glucose Analyzer, calibrated by YSI 2747 Glucose Standard (a NIST traceable glucose standard). The margin of error of the YSI 2300 Glucose Analyzer measurement is 0.289 mg/dL when the blood glucose concentration is higher than 100 mg/dL, or 0.029 mg/dL when the blood glucose concentration is lower than 100 mg/dL. (1 mmol/L= 18 mg/dL).

Send Message

Still searching for
physician?