Jaipur
+918529833535

'performance'

Items tagged with 'performance'

product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
Clinical Chemistry

With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Usage/Application Operation Theater Positioning Ceiling Mounted Model Name/Number HyLED 7 Series Brand Mindray Light Source Type LED Central illuminance at 1m distance 160,000 lux Light field diameter(at 1m distance) 180~300 mm Depth of illumination(L1+L2) 1,200 mm Correlated color temperature 4,350 K Color rendering index(Ra) 96 Color rendering index(R9) 97 Shadow dilution with tube 100% Shadow dilution with one mask 75% Shadow dilution with tube and one mask 70% Shadow dilution with two masks 55% Shadow dilution with tube and two masks 50% Ambient illumination 8,000 lux Bulb power consumption 85 W Power supply 100~240 VAC, 50/60 Hz Number of LED bulbs 32 Light head dimension 600 mm Integrated Camera Optional Carrier-arm Camera Optional HyLED 7 Series Contact Us With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Efficient & Economic • Incredible long service time up to 60,000 hours • Central Illumination: 160,000 lux/130,000 lux • Adjustable light field diameter • Max. depth of Illumination : 1,200 mm • Low power consumption Original & Unique • Perfectly integrated into laminar flow (Certified per DIN-1946 Part 4) • Touch screen panel for easier control • 330° rotatable integrated HD/FHD camera • Ultra-thin design & excellent maneuverability • Ergonomic and compact design less than 12kg Ergonomic and Compact Design • The ultra-thin concentrically circular design for better hygiene. • DIN-1946 Part 4 certificated. (12-2008) Flexible Design • Combined with an Ondal spring arm maximizes mobility and ensures stability. • Ultra-thin light head with only less than 12 Kg. • Smooth, metal back cover of the light head. High Performance • With a minimum lifetime of 60,000 hours, each latest generation LED illuminates far longer than traditional light sources. • Easier and less costly maintenance: each LED bulb with individual circuit can be replaced respectively, which will minimize the maintenance cost. Easy and Intuitive Control • Traditional control panel • Touch screen panel(optional) Shadow-free The HyLED 7 Series surgical light inherits the advanced technology from the HyLED 9 series and shows excellent shadow management function. The professional shadow dilution experiment simulated extreme situations by using tubes and masks proved that Mindray HyLED 7 Series surgical light has sufficient illumination even in extreme situations. Camera System for Communication The camera system provides better communication and documenting solutions. The camera system integrated with the surgical lights also provides a platform for medical research purpose, teaching communication and video documenting. Digital video recorder Supporting external USB storage device Supporting HDMI/YPbPr/HD-SDI/DVI-D/VGA input signal Default with camera control function Supporting video recording from other medical devices source

Send Message
product image
Instruments

The NB350 neonatal noninvasive ventilator is specially designed for neonatal ventilation, equipped with comprehensive NIV modes to provide reliable non-invasive respiratory support to meet the various needs of neonatal respiratory management. EasySync™ Technology The patented EasySync™ technology analyzes multi-channel parameters including gas flow and pressure without additional sensors, enabling accurate detection of spontaneous breath and improving synchrony in SNIPPV. The EasySync™ technology leads to a good synchronization performance comparable to electrical activity of the diaphragm (Edi). IOC (Intelligent Oxygen Control) The oxygen saturation of neonates tends to fluctuate, requiring caregivers to frequently adjust ventilator’s FiO2 settings. IOC (Intelligent Oxygen Control) achieves a closed-loop FiO2-SpO2 control by maintaining the patient’s SpO2 within the predetermined range, which reduces the workload of caregivers and improves patient safety. Integrated SpO2 monitoring for neonates in real time.1 Automatically adjust FiO2 setting by adaptive algorithm.2 Steadily maintain the SpO2 of neonates within the preset target range. Comfortable and Reliable Patient-interface The specialized patient-interface for the NB350 comes with a variety of sizes to fit for different clinical applications and patients. The ergonomic design with soft, skin-friendly material fully enhances the comfort of neonates throughout therapies. Bonnet/Headgear The bonnet/headgear integrate a fixings lot (seat) for pressure generator to avoid misposition and disconnection of patient-interface. Skin-friendly and breathable bonnet/headgear. Durable headgear hook-and-loop fastener allows easy and quick re-adjustment of the patient-interface. Infant Jet™ Pressure Generator Adjustable nasal prong/nasal mask positioning to adapt different facial orientations. Specifically designed to facilitate Coanda effect, significantly reducing respiratory resistance. Related Articles

Send Message
product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Laboratory Usage

Using best-in-class technology, the Mindray CL-6000i is a chemiluminescence immunoassay analyzer with high throughput, high performance and high reliability. Features Throughput: up to 480 tests per hour Measurement principle: enhanced ALP-AMPPD method Reagent carousel: 36 reagent positions with non-stop refrigerating Sample handling: up to 300 samples can be loaded in one batch, sample loading and offloading continuously by sample racks, fast prioritizing STAT samples Sample volume: 5-110 μL Continuously loading of reagents, substrate, cuvettes, wash buffer and waste bags Zero daily maintenance Product Specification Model Name/Number CL-6000i Usage/Application Hospital Brand Mindray Sample Volume Range 5-110 microlitre Throughput up to 480 tests per hour Measurement Principle enhanced ALP-AMPPD method Reagent Carousel 36 reagent positions with non-stop refrigerating Sample Handling up to 300 samples can be loaded in one batch,sample loading and offloading continuously by sample r

Send Message
product image
Immunology Analyzer

The CL-900i is a compact, fully-automated CLIA analyzer. With dimensions of just 86cm length, 72cm width, 56cm height, it is specially designed for small volume labs. The analyzer incorporates ergonomic design with an easy-access operating area, which is located on the cover. The machine does not require regular maintenance, providing our customers with the best operating experience, as well as competitive cost performance. Features Basic parameters: Measurement principle: enhanced ALP-AMPPD method Small footprint: 860mm*740mm*560mm (W*D*H) Throughput of up to 180 tests/hour 50 sample positions and 15 reagent positions Chemiluminescence Immunoassay Reagent Reagent Test Menu PC

Send Message
product image
Medical Equipment

In compliance with out-of-hospital patient transport standards such as EN1789, EN13718-1, IEC60601-1-12 and U.S. military standards, N1 is a highly competent solution for various out-of-hospital transport settings both on land and in air. The N1's exceptional reliability and strong performance enhance your confidence to provide seamless patient care during transport no matter intra or out of hospital. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. benevision-n1-fig2-1-pc BeneVision N1 as a Multi-Parameter Module Slide directly into the module slot or SMR of the N-Series monitor providing an expansive set of parameter measurements. When combined with our additional advanced parameter modules, this solution fits even the highest level of critical care environments. benevision-n1-fig2-3-pc Companion Mode Connect with N-Series host monitor via cable connection to N1 dock and have the ability for dual-screen monitoring and bi-directional control of the bedside monitor - expanding slot space for more advanced parameters and enhanced ICU workflow. Patient-Centric Data Collection When connected to a bedside patient monitor, advanced parameters collected from the host monitor such as AG and BIS, etc., will also be stored in N1 with trend data and alarm events reviewable even when it is disconnected.

Send Message
product image
Rapid Test

STANDARD F HbA1c FIA performs quantitative analysis on glycosylated hemoglobin in whole blood samples using fluorescence immunochromatography. As STANDARD F Analyzer has been enhanced in its performance by using fluorescent substance, accurate quantitative test results can be obtained using with this product. ntented Use This product performs quantitative analysis on glycated hemoglobin in the whole blood samples. Advantage Able to perform accurate quantitative analysis using fluorescent substance Hb S, Hb F, Carbamylated Hemolgobin without interference phenomenon Automatic strip recognition by reading the information stored in 2D barcode IFCC / NGSP certified Specification Specimen Whole blood Test time 5 minutes Specimen volume 5 µl CV% <3%

Send Message
product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message

Still searching for
performance?