Jaipur
+918529833535

'pc connecting'

Items tagged with 'pc connecting'

product image
immunoassayReagents

INTENDED USE The Finecare™ PCT Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Procalcitonin (PCT) in human whole blood, serum or plasma. This test is used as an aid to diagnosis severe, bacterial infection and sepsis. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ CRP/PCT Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of C-Reactive Protein (CRP) and Procalcitonin (PCT) in human whole blood, serum or plasma. This test is used as an aid to see infection and inflammation and used to aid in the early detection of clinically relevant bacterial infections. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Medical Equipment

In compliance with out-of-hospital patient transport standards such as EN1789, EN13718-1, IEC60601-1-12 and U.S. military standards, N1 is a highly competent solution for various out-of-hospital transport settings both on land and in air. The N1's exceptional reliability and strong performance enhance your confidence to provide seamless patient care during transport no matter intra or out of hospital. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. benevision-n1-fig2-1-pc BeneVision N1 as a Multi-Parameter Module Slide directly into the module slot or SMR of the N-Series monitor providing an expansive set of parameter measurements. When combined with our additional advanced parameter modules, this solution fits even the highest level of critical care environments. benevision-n1-fig2-3-pc Companion Mode Connect with N-Series host monitor via cable connection to N1 dock and have the ability for dual-screen monitoring and bi-directional control of the bedside monitor - expanding slot space for more advanced parameters and enhanced ICU workflow. Patient-Centric Data Collection When connected to a bedside patient monitor, advanced parameters collected from the host monitor such as AG and BIS, etc., will also be stored in N1 with trend data and alarm events reviewable even when it is disconnected.

Send Message
product image
Rapid Test

PCT-Q Rs: 1400 Per Test/- Pack Size: 25 Test A reliable diagnostic & prognostic marker for Systemic Bacterial infections, Serves Sepsis, Septic Shock - Highly Specific test to differentiate bacterial infection from viral infection - Increases rapidly within 6-12 hrs - Correlates well with the progression and severity of disesase Correlates well with the progression and severity of disesase * Helps in avoiding unnecessary antibiotic therapy, thereby reducing the cost and occurance of bacterial infection. Additional Information Payment Terms T/T (Bank Transfer)

Send Message
product image
Prescription drugs

The primer and probe mix adopts the dual-target gene design, which targets the specific conserved sequence encoding the ORF1-ab gene and the Nucleocapsid N gene. With the PCR reaction mix provided, the amplification of template can be monitored by the increasing fluorescence signal detected by a real time PCR instrument. The PCR detection system includes an endogenous internal control primer and probe mix. The result of internal control provides the accuracy of sampling and extraction process, in order to avoid false negative results. Pack Size: 100 Tests

Send Message
product image
Immunology Analyzer

Product Description: The LisaScan EM Microplate Reader is an economical, compact and versatile 8 channel ELISA reader which can be adapted to various ELISA applications. It is India’s largest selling automated microplate ELISA reader Product Features: Wavelength Range: 400 to 750nm with a dynamic measurement range of 0.0 to 4.0 O.D 100 user-programmable test storage Inbuilt thermal printer for reports & graphs Auto self-check on start-up & external printer connectivity Compatible to various plate geometrics-96 well microplates ( Flat, U & V bottom) Wavelength selection: Monochromatic, bi-chromatic & multi-chromatic* Reading time 8 sec. for single wavelength using 8-channel optics User-friendly inbuilt operation software with 7000 sample test results storage User interface: High Resolution LCD display with 20 Keys Rugged waterproof & membrane panel Computer linked ELISA data management software - Eli-LIMS* CE marked Inbuilt shaking facility,Three Linear Speeds - Low, Medium and Fast Reports can be printed using internal thermal or external printer No need of manual calculations and documentation Documentation ease – Reports can even be stored using optional Eli-LIMS software Computer can be connected Extensive ELISA data management Product Applications: ELISA System type: Open System Plate types: 96 well plates Wells Type: U, V and Flat bottom wells Operating Modes: Absorbance Quantitative Qualitative Semi-Quantitative Kinetic Mode Measurement Modes: Continuous / Step Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set Wavelength Selection: Monochromatic Bi-Chromatic Multi-Chromatic* (Maximum 4) Calculation Modes: Non-linear Standard Cut-off Index Formula Column Subtraction Linear Regression Point to Point Cubic Spline Linear – Log Blank Options: Blank, Control, Assay Validation equations Against Air, Well Plate, Column, Column-mean Row, Row mean Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters Test Programs: 100 totally “open” Test Programs Photometer: Measuring system: 8-Channel optical system Lamp Source: Tungsten Halogen with Lamp saver function Wavelength Range: 400 to 750 nm Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass Dynamic Range: 0.0 ~4.0 OD Photometric accuracy: < 1% at 2.5 OD at 450 nm Photometric resolution: 0.001 OD Linearity: <1% at 2.5 OD at 450 nm Measurement Time: SPEED : 8 Seconds single wavelength NORMAL : 17 Seconds single wavelength Display: High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm Keyboard: Rugged waterproof & membrane panel PC Communication: USB Based Protocol compatible with Eli-LIMS and TNW Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor). Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves. Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored. Lab name in Print-out Lab name in Display Collated reports Print-out of Normal Range along with the result (on external printer only). Graphs can be printed on Thermal Printer Sorted by: Date I.D. Both by Date & I.D. Test Plate ID Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad. Operating Temperature: 20˚ C to 40˚ C Storage Temperature: -10˚ C to 50˚ C Humidity: Max. 80% RH, non- condensing Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter 115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified) Dimension: 502 mm X 369 mm X 216 mm Weight: 7 Kg

Send Message
product image
Clinical Chemistry

Product Description: Fully Automated 5 Part Differential Analyser with continuous loading Product Features: Tri angle laser-based flow cytometry for WBC and differentials enumeration 33 reportable parameters including NLR, P-LCC, P-LCR, Mentzer index and RDWI 20 µl sample volume Throughput 80 samples/ hr Large storage capacity of 100000 samples Bidirectional Interfacing Large coloured LCD touch screen of 22 inch Product Application: CBC + Diff Analysis Mode Type: Whole Blood, Predilute, Capillary Autoloader: 60 Tubes; Continuous Loading with Auto-Mixing 33 Parameters: CBC: WBC, RBC, Hb, HCT, MCV MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-SD, PDW-CV, P-LCR, P-LCC, DIFF: Neutrophils % & #, Lymphocytes % & #, Monocytes % & #, Eosinophils % & #, Basophils % & # *ALY % & #, *LIC % & #, *NLR, *Mentzer index and *RDWI *Research use only Principle of Measurement: RBC/PLT/WBC : Electrical Impedance WBC DIFF: Tri-angle Laser Flowcytometry Hb: Cyanide Free Colorimetry MCV: Measured HCT: Calculated Histograms : 3 (RBC/WBC/PLT) Scattergrams : 3 (2D Scattergram), 1 (3D Scattergram) QR Code Reader: For reading sample bar codes & direct input of QC values Sample Volume: Whole Blood: 20 µL Pre- diluted: 20 µL Capillary: 20 µL CBC Mode : 13 µL Linearity Range: WBC : 0 - 300 ( x 103/µL) RBC : 0 - 300 ( x 103/µL) Hb: 0 - 25.0 (g/dL) HCT: 0 - 67 (%) PLT : 0 - 3000 (x 103/µL) Calibrator: ELite H Cal Tri-level Controls: Erba H5 CON L, N, H Open Vial Stability at 2 - 8˚C: 16 Days Throughput: 80 Tests/Hr Quality Control: 500 files with L-J Graph X- Bar Analysis Data Storage: 1,00,000 Results with Graphs Dimension (mm): 650x550x610 Weight (kgs): 59 Reagents: ELite 580 Dil ELite H580Lyse1 ELite H580Lyse2 ELite H580Lyse3 Elite H Clean Interfaces: 4 USB ports ( for connecting external devices including external printers) + 1 LAN Port (HL 7, TCP/IP; LIS connectivity) Operating Environment Temperature: 15-40˚C Humidity: 30-90% Power Requirement: A.C. 100 - 240 V with built-in voltage stabiliser 50/60Hz, 200 VA

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ AMH Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative measurement of AMH in human whole blood, serum or plasma. The test is mainly used in the assessment of the ovarian reserve and as an aid in the diagnosis of polycystic ovary syndrome (PCOS). STORAGE AND STABILITY 1. Store the test kit at 4~30°C up to the expiration date printed on the package. 2. If removed from refrigerator, allow the test to return to room temperature for 30 minutes before testing. 3.Do not remove the cassette from the pouch until ready to use. The test cassette should be used within 1 hour once opened.

Send Message

Still searching for
pc connecting?