Jaipur
+918529833535

'patients information'

Items tagged with 'patients information'

product image
Instruments

A high-end ventilator featured with 1080P HD wide screen, combines an intuitive customized UI with powerful assistive tools and modules. Operate with Ease In the modern busy clinical environment, ease of use is a fundamental requirement for all medical devices. With this in mind, the new SV800/SV600 ventilators enable clinicians to set and deliver ventilation therapies quickly and easily via the intelligent ergonomic design and flat user interface. Intelligent Decision Making Ventilation modes and decision-supporting tools like SBT are developed on the basis of clinical needs and professional guidelines to help free up medical personnel’s time on device operation and focus more on their patients. p68-s4 Extensive ventilation therapy and decision support tools Smart ventilation solution: AMV TM + IntelliCycle TM Emergency solution: CPRV TM Sequential treatment regimen: Non-invasive ventilation & high flow oxygen therapy Dual channel auxiliary pressure measurements Lung protection kit Expandable Capabilities Securing your devices future is reliant on being able to expand your devices capabilities by interacting or integrating new features and technologies. The SV800/SV600 ventilators allow just this. Thanks to latest software and platform it is utilizing, your device is ready to embrace new technological advancement with ease. p68-s0-0 Integrated neonatal module with tidal volume setting down to 2ml Plug & Play modules , including SpO₂, mainstream or sidestream CO₂ Backup air supply in case of central air supply failure and during intra-hospital transport Seamlessly connected to the hospitals clinical information system via the Mindray BeneLink and eGateway modules, or directly via the HL7 p68-s5 Brand - Mindray Model Name/Number SV800 Patient Age Group Adult, Pediatrics & Neonatal Tidal Volume For adult : 100 to 4000 ml, For Pediatric 20 to 300 ml, For neonatal : 2 to 100 ml Ventilation Mode V-A/C, P-A/C, V-SIMV,P-SIMV, Duolevel, CPAP, PSV, APRV, PRVC, NIV, PRVC-SIMV, AMV, CPRV, PSV-S/T, nCPAP, VS Respiratory Rate For adult/pediactrics : 1 to 100/min,for neonate :-1 to 150/min Additional Details Weight 45 kg ventilator + 16.3 kg trolley Plateu (%) OFF, 5% to 60% Peak airway pressure 0 to 100 cm H2O SIMV Rate ,Cycle/min 1 to 60 rpm Mounting type Trolley I:E Ratio 1:10 to 4:1 Touch screen 18.5 inch color active matrix TFT touch screen RSBI 0-9999/1/(L-min) Features Customizing the UI Graphic guidelines Single level menu design Dual channel auxiliary pressure monitore

Send Message
product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Rapid Test

Buy AccuTest HCV Rapid Card Test (30 Tests) Online from Accurex. HCV means Hepatitis C Virus which is a is a small, enveloped, positive-sense, single-stranded RNA virus. Hepatitis C symptoms are fever, fatigue, decreased appetite, nausea, vomiting, abdominal pain, dark urine, pale feces, joint pain and jaundice. HCV test is a rapid Chromatographic Immunoassay work on principle of the double antigen sandwich technique, Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. AccuTest HCV Test is a rapid Chromatographic Immunoassay for the Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. Hepatitis C Virus (HCV) is a small, enveloped, positive-sense, single-stranded RNA virus. Antibody to HCV is found in over 80% of patients with well documented non-A, non-B hepatitis. Conventional methods fail to isolate the virus in cell culture or visualize it by electron microscope. Cloning the viral genome has made it possible to develop serologic assays that use recombinant antigen, multiple antigens using recombinant protein and/or synthetic peptides have been added in new serologic tests to avoid nonspecific cross-reactivity to increase the sensitivity of HCV antibody tests. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or quest Principle: AccuTest HCV Rapid Hepatitis C Virus Test (Serum/Plasma/Whole Blood) is a lateral flow chromatographic immunoassay based on the principle of the double antigen-sandwich technique. The membrane is coated with recombinant HCV antigen on the test line region of the device. During testing, the serum/plasma or W.Blood specimen reacts with HCV antigen coated particles. The mixture migrates upward on the membrane chromatographically by capillary action to react with recombinant HCV antigen or membrane and generate a colored line. Presence of this colored line indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear at the control line region, indicating that the correct volume of specimen has been added and membrane wicking has occurred. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Safety Information •Positive: If a distinct purple line is formed at the test one marked ‘T’ (Test Line) and the Control Zone marked ‘C’ (Control Line) the test result is positive, indicating the sample contains Hepatitis C antibody. The interpretation of test results (+ve for hepatitis) remains unchanged even if there is a difference in intensity of color in positive line and control line as is many a time found. •Negative: If a distinct purple line is formed only at the control zone marked ‘C’ (control line) the test result is negative • Invalid: A total absence of color in both © and (T) regions or no colored band appears on the control © region is an indication of procedure error and/or the test reagent has deteriorated. Repeat with a new test kit. Direction for Use Test Procedure 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Other Info Storage and Stability AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch.

Send Message
product image
Rapid Test

Buy AccuTest H Pylori AB Rapid Card Test (50 Tests) Online from Accurex. The Helicobacter Pylori is a lateral flow chromatographic immunoassay for the qualitative detection of antibodies to H.pylori in human Whole Blood/Serum/Plasma. H Pylori test provides an aid in the diagnosis of infection with H.pylori. H.pylori is implicated in the etiology of a variety of gastrointestinal diseases, including duodenal and gastric ulcer, non-ulcer dyspepsia and active and chronic gastritis. h pylori symptoms are an ache or burning pain in your stomach (abdomen), Nausea, Loss of appetite, Frequent burping, Bloating & Unintentional weight loss NTENDED USE The H.pylori Antibody Rapid Test Card is a lateral flow chromatographic immunoassay for the qualitative detection of antibodies to H.pylori in human Whole Blood/Serum/Plasma. It provides an aid in the diagnosis of infection with H.pylori. INTRODUCTION H.pylori is implicated in the etiology of a variety of gastrointestinal diseases, including duodenal and gastric ulcer, non-ulcer dyspepsia and active and chronic gastritis. H.pylori infection is found in more than 90% of duodenal ulcer patients and in around 75% of all peptic ulcer sufferers. H.pylori infection is also more common in gastric cancer patients. The risk of gastric cancer has been estimated to be six-fold higher in H.pylori infected populations than in uninfected populations. H.pylori infections occur in human populations throughout the world. In developed countries, about 50% of the population may have H.pylori infection by the age of 60 years, while only 10-20% of adults in the third decade of life have it. Transmission is most probably by the fecal-oral or oral-oral route. Both invasive and non-invasive methods are used to diagnose H.pylori infection in patients with symptoms of gastrointestinal disease. Invasive methods include culture of gastric biopsy samples, histologic examination of stained biopsy specimens, or direct detection of the urease activity in the biopsy (CLO test). These methods need to obtain a biopsy sample by endoscopy.which is expensive,and usually results discomfort and risk to the patient.noninasive techniques include urea breath tests and serological methods. Urea breath test requires expensive laboratory equipment and moderate radiation exposure. Serologic tests are employed to detect antibodies as human immune response to H.pylori, for example the ELISA and the Western immunoblot. The H.pylori Antibody Rapid Test Card detect antibodies to H.pylori infection in human Whole Blood/Serum/Plasma. It is a noninvasive method and does not use radioactive isotopes. The test is easy to perform and requires no specialized equipment. Visual interpretation provides an accurate qualitative result. It is a useful on-site aid in the diagnosis of H.pylori infection. Diagnosis of H.pylori infection by antibody immunoassay can reduce the number of patients requiring endoscopy. PRINCIPLE The H.pylori Antibody Rapid Test Card is an immunoassay based on the principle of the double antigen-sandwich technique. During testing, a Whole Blood/Serum/Plasma specimen migrates upward by capillary action. The antibodies to H.pylori if present in the specimen will bind to the H.pylori conjugates. The immune complex is then captured on the membrane by the pre-coated H.pylori antigens, and a visible pink-purple line will show up in the test line region indicating a positive result. If antibodies to H.pylori are not present or are present below the detectable level, a pink-purple line will not form in the test line region indicating a negative result. To serve as a procedural control, a pink-purple line will always appear at the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred. Safety Information The H.pylori Antibody Rapid Test Card is limited to provide a qualitative detection. The intensity of the test line does not necessarily correlate to the concentration of the antibody in the blood. x The results obtained from this test are intended to be an aid in diagnosis only. Each physician must interpret the results in conjunction with the patient’s history, physical findings, and other diagnostic procedures. x A negative test result indicates that antibodies to H.pylori are either not present or at levels undetectable by the test. Direction for Use TEST PROCEDURE 1. Remove the test cassette from the sealed pouch and use it as soon as possible. 2. Place the test cassette on a clean and level surface. 3. For serum or plasma specimen: Hold the dropper vertically and transfer 3 drops of serum or plasma to the specimen well (S) of the test cassette, then start the timer. See illustration below. 4. For whole blood specimens: Hold the dropper vertically and transfer 1 drop of whole blood (approximately 30μl) to the specimen well(S) of the test cassette, then add 2 drops of buffer (approximately 70μl) and start the timer. 5. Read results at 15 minutes. Do not interpret the result after 20 minutes. Other Info STORAGE AND STABILITY x Store as packaged in the sealed pouch at 4-40℃. The kit is stable within the expiration date printed on the label. x Once open the pouch, the test should be used within one hour. Prolonged exposure to hot and humid environment will cause product deterioration.

Send Message
product image
Clinical Chemistry

Product Specification Model Name/Number i15 Brand Edan Usage/Application Laboratory Use Throughput Results In 1 Minute After Sample Aspiration Weight 3.65 Kg Battery 5000 mAh Rechargeable Lithium-Ion Battery Dimensions 238*153*310 mm (W x H x D) Display Type 7 Inch LCD Display Frequency 50 Hz Interface 4 USB 2.0 Host,1 RS232,WLAN Voltage 110- 240 V Input Device Touch Screen And Barcode Scanner Operating Temperature 10-30 Degree C Product Description Portable, lightweight Capable to run 50 samples with fully-charged battery Diagnose at the point of care, patient side, out in the Field or exam room Easy, Quick and Convenient Zero maintenance Minimize hands on time and training requirement Auto-sampling Report is ready within one minute after sample aspiration Accurate and Reliable Innovative microchip liquid control technology and micro-sensor multifunction membrane technology High sensitivity and accuracy Calibrator, Control and Electronic simulator to TRIPLE guarantee the RESULTS! Flexible Data Management Acquire patients' information via barcode/QR code Up to 10,000 patient data storage 4 USB ports and LAN/WiFi for data management Optional data management software Multi-parameter cartridge Multi popular time-sensitive parameters come in one cartridge, including ABG, electrolytes and metabolites Single-use cartridge avoids contamination Room temperature storage with long shelf-life

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ HbA1c Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Hemoglobin A1c in human blood. The test is used as an aid to monitor long-term glycemic status in patients with diabetes mellitus. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Rapid Test

Intended Use Covid 19 Ag Card Test is designed for in vitro qualitative detection of Covid 19 antigen in human nasopharyngeal, nasal swab specimens. The kit is intended for professional use and as a screening test and is an aid in early diagnosis of SARS COV-2 infection in patients with clinical symptoms. Salient Features Rapid Visual Test for the Qualitative Detection of Covid-19 (SARS-COV-2) antigen in Human nasopharyngeal and nasal swab specimens. Based on Sandwich Immunoassay principle. Results within 20 minutes. Single step test procedure. Evaluated & Validated by ICMR Centre ; Sensitivity -91.5% (<30 CT) & Specificity -100% against RT-PCR. Long Shelf life:30 months at 2-30° C. No Instruments required. Convenient pack sizes . 10T,25T,50T,100T & 200T.

Send Message
product image
Rapid Test

Intended Use Dengue NS1 Antigen self-test is a rapid solid phase immune-chromatographic test for the qualitative detection of Dengue NS1 Ag in human whole blood/serum/plasma. This test is intended to be for home use with self-collected whole blood specimens from individuals aged 18 years or above( or collected by adults for individuals below 18 years of age) as well as for professional use with venous Whole blood/Serum/Plasma samples. This test is for in-vitro diagnostic use only & is designed as an aid in the early diagnosis of dengue infection patients with clinical symptoms. Salient Features Rapid, Visual, Home test for qualitative detection of Dengue NS1 antigen detection in human whole blood/serum/plasma. Finger prick sample can be used. Single test pack. All material to perform the test & its disposal are provided with the kit. Based on Sandwich principle.\ Detection of Dengue in Seronegative stage i.e. from Day 1 of fever. Detection of all 4 serotypes of dengue virus. Reliable diagnosis of both primary and secondary infection. 100% Sensitivity & 100 % Specificity. Shelf life: 30 month at 2-30 °C.

Send Message

Still searching for
patients information?