Jaipur
+918529833535

'pathological changes'

Items tagged with 'pathological changes'

product image
Instruments

Operate with Ease In the modern busy clinical environment, ease of use is a fundamental requirement for all medical devices. With this in mind, the new SV600 ventilators enable clinicians to set and deliver ventilation therapies quickly and easily via the intelligent ergonomic design and flat user interface. PulmoSight TM Utilizes numerical and graphical displays to show real time resistance, compliance and the spontaneous breathing status. Combined with the dynamic short trend display clinicians are able to monitor and evaluate changes in the patient's pulmonary ventilation and initiate the appropriate therapies. User configurable UI The SV600 ventilators offer exceptional user flexibility. Users are able to configure frequently used parameter controls by making them quick access shortcut keys in the UI. Also the ventilation mode keys can be arranged in order of frequency of use. This enables you to customize device in your way making parameter adjustment easier and quicker. Graphic guidelines The new intuitive graphical display enables users to learn quickly how to navigate and locate mode and parameter controls, thereby reducing errors and improving efficiency. Minimal Maintenance Routine maintenance requires no tools. The new 'door design' means that no tools are required to perform regular routine maintenance of the oxygen sensors, water trap, fan dust filter, HEPA air intake dust filter, etc. This ensures your new device always remains clean and clutter free. Intelligent Decision Making Ventilation modes and decision-supporting tools like Intelligent Assistant are developed on the basis of clinical needs and professional guidelines to help medical personnel calmly make clinical decisions. An extensive range of ventilation modes Smart ventilation solution: AMV TM + IntelliCycle TM Emergency solution: CPRVTM Sequential treatment regimen: Non-invasive ventilation & high flow oxygen therapy Dual channel auxiliary pressure measurements Lung protection kit Expandable Capabilities Securing your devices future is reliant on being able to expand your devices capabilities by interacting or integrating new concepts and technologies. The new SV800 / SV600 ventilators allow just this. Continue the latest electronic software and hardware, your new device is ready to embrace new technological advancement with ease. Integrated neonatal module with tidal volumes as low as 2 ml Plug & Play modules , including SpO2, mainstream or sidestream CO2 Backup air supply in case of air supply failure Seamlessly connected to the hospitals clinical information system via the Mindray BeneLink solution or eGateway solution Brand Mindray Model Name/Number SV600 Patient Age Group Neonatal, Adult, Paediatric Mounting Type ICU Operating Type Automatic Display Full color 15.6 inch Resolution 1920x1080 pixel Compliance IEC 60601-1-2 for EMC

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Gluco + Test Strips (Pack of 50 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips require a sample volume of 0.5 μL and taking just 5 seconds to return a test result. XPRESSGLUCO+ strips make the testing experience superior. These Glucometer strips are for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh Accurex Blood Glucose test strips provide accurate results in just 5 seconds. XPRESSGLUCO+ Blood Glucose Test Strips are used with the XPRESSGLUCO+ Blood Glucose Meters. They are intended for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh. They are for testing outside the body (in vitro diagnostic use only). Donot use them for diagnosis of diabetes or testing on neonates. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Safety Information • Discard used test strips and lancets responsibly according to your local regulations. • Keep test strips vial away from children. A child could choke on the test strips. The test strips and their vial contain agents that may be harmful if swallowed. If they are swallowed, promptly see a doctor for immediate assistance. Do not change medication based on the test results without the advice of a physician or healthcare professional. Direction for Use • Prior to first use, ensure that the package is undamaged and closed. • Keep the test strip vial away from sunlight and in a cool, dry place between 5 – 40°C (41 – 104°F). Do not freeze it. • Store test strips in their original pack only. Do not put the test strips in any other container. • Use test strips immediately after removing from the package. • Do not use test strips after the expiration date. • Avoid getting dirt, food or water on the test strip. Do not handle test strips with wet hands. All parts of the test strip should be touched only with dry and clean fingers. • Do not perform blood glucose tests at a temperature below +10°C (50°F) or above +40°C (104°F), or above 85% relative humidity Other Info Each test strip is plasma-calibrated†, requiring a sample volume of 0.5 μL and taking just 5 seconds to return a test result. The test range is 20 to 600 mg/dL (or 1.1 to 33.3 mmol/L) with resolution at 1 mg/dL (0.1 mmol/L). †Plasma-calibrated: Test results produced on capillary whole blood samples by XPRESSGLUCO+ System are compared with the results of the corresponding plasma samples tested by the YSI 2300 Glucose Analyzer, calibrated by YSI 2747 Glucose Standard (a NIST traceable glucose standard). The margin of error of the YSI 2300 Glucose Analyzer measurement is 0.289 mg/dL when the blood glucose concentration is higher than 100 mg/dL, or 0.029 mg/dL when the blood glucose concentration is lower than 100 mg/dL. (1 mmol/L= 18 mg/dL).

Send Message
product image
Glycohemoglobin Analysis

XPRESSGLUCO+ strips make the testing experience superior. These Glucometer strips are for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco + Test Strips (Pack of 100 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips require a sample volume of 0.5 μL and taking just 5 seconds to return a test result. XPRESSGLUCO+ Blood Glucose Test Strips are used with the XPRESSGLUCO+ Blood Glucose Meters. They are intended for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh. They are for testing outside the body (in vitro diagnostic use only). Donot use them for diagnosis of diabetes or testing on neonates. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Safety Information • Discard used test strips and lancets responsibly according to your local regulations. • Keep test strips vial away from children. A child could choke on the test strips. The test strips and their vial contain agents that may be harmful if swallowed. If they are swallowed, promptly see a doctor for immediate assistance. Do not change medication based on the test results without the advice of a physician or healthcare professional. Other Info Each test strip is plasma-calibrated†, requiring a sample volume of 0.5 μL and taking just 5 seconds to return a test result. The test range is 20 to 600 mg/dL (or 1.1 to 33.3 mmol/L) with resolution at 1 mg/dL (0.1 mmol/L). †Plasma-calibrated: Test results produced on capillary whole blood samples by XPRESSGLUCO+ System are compared with the results of the corresponding plasma samples tested by the YSI 2300 Glucose Analyzer, calibrated by YSI 2747 Glucose Standard (a NIST traceable glucose standard). The margin of error of the YSI 2300 Glucose Analyzer measurement is 0.289 mg/dL when the blood glucose concentration is higher than 100 mg/dL, or 0.029 mg/dL when the blood glucose concentration is lower than 100 mg/dL. (1 mmol/L= 18 mg/dL).

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Glucometer Plus Kit Online, it’s a smart Glucometer Machine kit. This Digital Glucometer consists of 1 Blood Glucose Meter, 10 Test Strips, 1 Multilet Lancing Device, 10 Sterile Lancets, 1 Carry Pouch, 1 Warranty Card, Test Strip Insert Sheet, 1 Battery (3V) Gluco Plus Meter is intended for use in the home & in clinical settings. There are different types of Glucometers in Point of Care (POC). XPRESSGLUCO + meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). The system is intended for use outside the body (in vitro diagnostic use only). It should be used only for self-testing blood glucose (blood sugar) and only with fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh. The system is intended for use in the home and in clinical settings. The system should not be used for the diagnosis of diabetes or for the testing of newborns. Blood glucose is measured by an electrical current that is produced when a blood samples mixes with the reagent (special chemicals) of the test strip. The electrical current changes with the amount of glucose in the blood sample. The XPRESSGLUCO+ meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). Safety Information 1. The user should not take any decision of medical relevance without first consulting his or her medical practitioner. 2. Call your doctor immediately if you experience symptoms that are not consistent with your blood glucose test results. 3. High altitudes above than 3,402 meter (11,161 ft) may affect the test results. 4. Temperatures outside the range of 10°C to 40°C (50°F to 104°F) may affect the test results. Do not test beyond of temperature range. 5. Do not perform servicing and maintenance while the meter is in use. 6. No modification of this equipment is allowed. 7. Do not use this meter near cellular or cordless telephones in a call, walkie-talkies, garage door openers, radio transmitters, or other electrical or electronic equipment that are sources of electromagnetic, radiation, as these may interfere with the proper operation of the meter. Direction for Use 1. Wash you hands and puncture sit: Wash your hands in warm, soapy water. Rinse and dry completely . Warm your fingers to increase blood flow. 2. Insert Test Strip : Remove a new test strip from vial. Be sure to tightly replace vial cap after removing test strips. Insert a test strip with the contact bar end entering into the test strip slot first. Push the test strip as far as it will go without bending it. The meter turns on automatically. 3. Hold the prepared lancing device firmly against the side of your fingertip. Press the release button. (NOTE : If you want to do alternative site testing, please refer to the “About Alternative Site Testing (AST)” section. Please consult your healthcare professional before obtaining blood from site other than your fingertip.) 4. Obtain a Blood Sample : Gently massage your finger or puncture site to obtain the required blood volume. To perform the test, you need only 0.5 μL of blood sample. Do not smear the blood sample. To obtain best accurate result, wipe off the first drop of blood and gently squeeze another drop of blood. 5. Apply Blood Sample : When the meter shows the “ ” symbol, apply blood to the opening of the absorbent channel of the test strip where it meets the narrow channel. Blood will be drawn into the test strip. If the test strip confirmation window is full, you will hear a beep. 6. Read Your Result : After the meter counts down from 5 to 1, your blood glucose test result appears along with the unit of measure, date and time. Test result is lower than the target range Test result is within the target range. Test result is higher than the target range *The default target range is 70 mg/dl to 180 mg/dl. 7. Turn Off the Meter : This blood glucose result is automatically stored in the meter memory. Turn the meter off by removing the test strip. Discard the used test strip carefully to avoid contamination. 8. After use, twist off the Lancing Device Cap. Push the exposed tip of the lancet into its Protective Cap. 9. Slide the Lancet Ejector forward and disposing the used lancet in an approved container. Discard the used lancet according to your country’s safety regulations. Replace the Lancing Device Cap. Other Info •Use only XPRESSGLUCO+ Control Solution with your XPRESSGLUCO+ meter. •Check the expiration date on the bottle. Do not use if expired. •Use within a period of 90 days from the date that you first open it. Record the discard date on the control solution bottle when you first open it to serve as a reminder to discard after 90 days. •The control solution ranges are printed on the label of the XPRESSGLUCO+ Blood Glucose Test Strip vial. They are not recommended target ranges for your blood glucose. •For in vitro diagnostic use. •Do not add any liquid to the XPRESSGLUCO+ Control Solution. •Do not take internally or inject.

Send Message

Still searching for
pathological changes?