Jaipur
+918529833535

'outer diameter 5 mm length'

Items tagged with 'outer diameter 5 mm length'

product image
Laboratory Testing Analyzer

For smaller Laboratories Smaller, but with full functionality Compact size Full functions and performance in a compact size. *Size comparison with HA-8180V Accuracy HPLC technology provides accurate results-inluding detailed chromatogram. it will be shown in both IFCC and NGSP units. Cap-piercing method ADAMS Lite uses a cap-piercing method which enables the placement of capped blood samples. This not only reduces the workload but also helps protect lab technicians from infection. Easy-to-maintain No special tools are required for daily maintenance. Exchanged parts are hand-tightened, minimizing the workload of users. Specifications Measurement objects Whole blood or hemolysis sample Measured items Fast Mode: HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode: HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed). Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm/500 nm (Dual-wavelength colorimetry) Resolution 0.1% Ratio, 1 mmol/mol Measurement range HbA1c: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Processing speed Variant mode: 160 seconds/test Fast mode: 100 seconds/test Sample consumption Whole blood sample: Approximately 4µL Anemia sample: Approximately 8 µL Hemolysis sample: Approximately 350 µL Sample container Sample tube: (12.3 or 15 mm in outer diameter) × (75 to 100 mm in height) Sample cup: 500 µL Sample supply Piercing sampling Compatible rack type ARKRAY racks (for 5 samples) Operating environment Temperature: 10 - 30°C; Humidity: 20 - 80% RH (No condensation) Display 20 digits × 2 lines LCD Printer For use with 58-mm width thermal printer paper Number of measurement samples Maximum 10 samples Power requirements AC 100 - 240 V±10%, 50/60 Hz Dimensions 330 (W) × 515 (D) × 485 (H) mm (Not including protrusions, eluent packs and hemolysis washing solution bottle)

Send Message
product image
Immunology Analyzer

The EUROIMMUN Analyzer I is an open system for fully automated ELISA processing of up to 7 microplates and 180 patient samples in one run. The combination of EUROIMMUN ELISAs and EUROIMMUN Analyzer I enables a quick and simple, but also a secure routine operation, owing to the automatic recognition and allocation of reagents and the import of QC data via Data Matrix codes. A further quality feature is the optionally available climate control unit, which ensures constant incubation conditions — regardless of fluctuating or excessively high laboratory temperatures. The EUROIMMUN Analyzer I is designed for medium to high sample volumes. Fully automated ELISA processing for medium to high sample volume with minimal manual input High reliability and traceability due to automatic identification of barcodes of patient samples and ready-to-use reagents Fast processing of up to 70 tests per hour and up to 7 plates and 180 samples per run Convenient operation of the software including scanning of QC certificates using a 2D-hand barcode scanner Specifications Sample types Plasma, serum, CSF and stool Patient sample capacity up to 180 samples Plate capacity up to 7 Parameter capacity per run up to 54 Shakeable incubators 4 Throughput up to 70 tests per hour Sample tubes Outer diameter 10 – 16 mm, height up to 100 mm Traceability integrated code scanner for identification of samples and reagents User interface Microsoft ® Windows ® 10 Enterprise 2019 LTSC (64 Bit) Online connection ASTM interface, bi-directional Dimensions (WxDxH) 1100 mm x 750 mm x 1000 mm Weight 130 kg

Send Message
product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180T is a fully automated Glycohemoglobin analyzer based on HPLC (High Performance Liquid Chromatography) and is highly effective for ß-thalassemia testing. Measurement speed: 3.5 minutes/test Measurement Item as below HbA2 HbF HbA1c (Stable HbA1c, S-A1c), HbS, HbC, HbE and HbD can be detected. Column design with no more pre-filter change. Color LCD with reagent level, graphs on screen. Samples Whole blood or hemolysis sample Measurement items HbA1c(Stable HbA1c, S-A1c), HbA2 and HbF (HbS, HbC, HbE and HbD can be detected.) Reagents *1 ELUENT 80A, ELUENT 80B, ELUENT 80CT and HEMOLYSIS WASHING SOLUTION 80H Column *2 COLUMN UNIT 80T Measurement principle Reversed-phase cation exchange chromatography Detection method Dual-wavelength colorimetry (wavelengths measured: 420nm/500nm) Resolution 0.1% Ratio, 1 mmol/mol Measurement range *3 HbA1c : 3-20%, 9-195 mmol/mol HbA2 : 2-10% HbF : 0-100% Guaranteed measurement range *4 HbA1c : 4.2-12.9%, 22-117 mmol/mol HbA2 : 2.4-6.3% HbF : 0.1-14.3% Processing speed 210 seconds per sample Sample consumption Approx.14μL(whole blood) Sample container Blood collection tube (12.3 to 15mm diameter) × ( 75 to 100mm length) Sample cup(500μL) Sampling method Cap-Piercing Rack type ARKRAY racks Number of measurement samples One-way transportation (factory set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approx. 39℃ Display Color graphic LCD with backlight Memory capacity 500 test results ( including calibration results ) Built-in Printer Termal printer, 58mm thermal paper External output Serial 1 port (Can be optionally used as an Ethernet port.) Measurement conditions Temperature : 15-30℃ Humidity : 20-80% relative humidity (non-condensing ) Required sample volume Blood collection tube : Minimum 10mm away from the bottom Sample cup : 400μL or more Warm-up time Maximum 30 min. Dimensions 530(W)×530(D)×530(H)mm (Not including the hemolysis washing solution bottle) Weight Analyzer: Approx. 39kg, Sampler: Approx. 4kg Power supply AC100V-240V ±10% 50/60Hz Power consumption Max. 300 VA *1, *2 Reagents and column are sold separately from HA-8180T analyzer. *3 Error-free measurement ranges. *4 Guaranteed ranges for obtaining results equivalent to those from HA-8160 TP mode measurement. ※Design and specications may be changed without prior notice

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message
product image
Rapid Test

Buy AccuTest Syphilis Rapid Card Test (50 Tests) Online from Accurex. This Syphilis test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. Syphilis is caused by the bacterium Treponema pallidum. There different types of test like VDRL test, RPR test, FTA-ABS, etc. AccuTest Syphilis Test Kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity & specificity of 99.67%. Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. AccuTest Syphilis Rapid Test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. This kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity and specificity of 99.67%. 1. AccuTest Syphilis is a chromatographic immunoassay kit for rapid qualitative detection of Treponemal antibodies (IgA, IgM, IgG) generated against Treponema pallidum Antigens (17KDa, 15KDa, 47KDa) in human serum or plasma with high sensitivity and specificity. 2. Results just in 5-20 minutes 3. Accu Test Syphilis exhibits sensitivity and specificity of 99.67%. Features: Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. After the specimen is added to the specimen well in the device, it reacts with syphilis antigen coated particles in the test. The mixture migrates chromatographically along the length of the test strip and interacts with the immobilized syphilis antigen. The double antigen test format can detect IgA, IgG & IgM in specimens. If the specimen contains TP antibodies a coloured band will appear in the lest line region indicating a positive result. In the absence of TP antibodies a coloured band will not appear in the region indicating a negative result. To serve as a procedural control, a coloured band will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred. Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Direction for Use Procedure: 1. Bring the pouch to room temperature before opening to avoid condensation of moisture on the membrane of the device. Also bring the specimen to R.T. prior to testing. 2. Label the device with patient’s identification. 3. Add 2-3 drops (approx. 30 pl) of sample into the sample well of the test device. Avoid overflowing. 4. Wait for 5 – 20 minutes and read the result. It is important that the background is clear beforg the result is read. Note: Do not read the result after 30 minutes since specimen back flow may cause false result. STORAGE, STABILITY & HANDLING 1. The kit should be stored at 2 – 30° C. Do not freeze. 2. Do not use the kit past the expiration date stated on label. 3. Take off the device from the sealed pouch just before use as the device is sensitive to humidity and heat.

Send Message
product image
Protine Analysis

“PA54 Specific Protein Analyzer performs tests in just three simple steps.it helps in monitoring of Inflamation, Rheumatism, Diabetes, Hemostasis, Renal Function, Cardivascular and immunological diseases.” Features: Parameters: HS-CRP, CRP, HbA1c, mALB, D-Dimer, Anti-CCP, RF, ASO, CYS-C, IgA, IgM, IgG, C3, C4, etc. Can be extended more than 30 parameters Sample type: Whole blood, serum, plasma, urine etc. Product Specification Model PA 54 Usage/Application Laboratory Use Display Type Digital Display 5.6 inches color touch screen Wavelength Range 650 nm Brand Operon Power supply AC 100-240V 50/60Hz Working temperature 10~30 degree C Memory 100,000 results storage Reaction time 1.5~3min Testing Channel 4 independent channels Light Source Diode laser Throughput 160 samples/hour

Send Message

Still searching for
outer diameter 5 mm length?