Jaipur
+918529833535

'other respiratory disorders'

Items tagged with 'other respiratory disorders'

product image
Rapid Test

Buy AccuTest COVID-19 IgG/IgM Rapid Test (Pack of 10 Tests) Online. COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. PRECAUTIONS & WARNING 1. This package insert must be read completely before performing thetest. Failuretofollow directions in insert may yield inaccurate test results. 2. Test results should be read between 10 and 15 minutes after aspecimenisapplied to the sample well. Results read after 20 minutes may giveerroneousresults.3. Do not open the sealed pouch until you are ready to conduct theassay.Onceopened, the cassettes should be used immediately. 4. Do not use expired devices. 5. Bring all reagents to room temperature (15-30°C) prior to use. 6. Do not mix components from different kits. Use only the buffer suppliedalongwith the kit. 7. Wear protective clothing and disposable gloves while handling thekit reagentsand clinical specimens. Wash hands thoroughly after performing thetest. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents arebeinghandled. 9. Dispose of all specimens and materials used to performthe test as biohazardouswaste. 10. Handle the negative and positive controls in the same manner as patientspecimens for operator protection. 11. Do not perform the test in a room with strong air flow, i.e. an electricfanorstrong air-conditioning. 12. Do not touch result window. 13. Use only for in-vitro diagnostic purpose.

Send Message
product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 60 Diagnostic Reagent (Pack Size : 12 x 5 ml) from Accurex. Alkaline Phosphatase 60 are used in the diagnosis of hepatobiliary disorders and bone disease associated with increased osteoblastic activity. Alkaline Phosphatase high levels may be a sign of a liver problem or a bone disorder Alkaline Phosphatase 60 reagent is set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP), the reagent is a Highly stable reagent & its activity can be determined in just 2.5 minutes. About Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Pack Size : 12 x 5 ml Principle The working solution is stablə for 21 days at 2- 8°C. The working solution should be prepared and stored in the dark (working solution bottle) provided.This is critical because the reagent is light sensitive. It should therefore be kept away from direct light. Alkaline Phosphatase cleaves p-nitrophenyl phosphate (p-NPP) into p-nitrophenol and phosphate. p-nitrophenol is a yellow color compound in alkaline medium and absorbs light at 405 nm. The rate of increase in absorbance at 405 nm. is proportional to Alkaline phosphatase activity in specimen. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label. The working solutions of Non Prostatic Acid Phosphatase & Total Acid Phosphatases are stable for 7 days at 2-8°C.

Send Message
product image
HEMOGLOBIN METER

Mispa HbX Portable Haemoglobin Analyzer Overview Mispa HbX , Smart Haemoglobin analyzer is a symbol of advanced point of care equipment with modern technology and convenience, designed to deliver high accuracy, quality results with least turnaround time and low maintenance. Best in Class Hemoglobin Meter Mispa HbX, the Smart Haemoglobin Analyzer, is the best example of an advanced point-of-care hemoglobin reader with modern technology. It is easy to use and designed to deliver accurate, high-quality results with the shortest turnaround time and minimal maintenance. This digital Hb meter is one of the best hemoglobin meters available. Working of A Hemoglobin Meter or a hemoglobin reader A hemoglobin meter or a hemoglobin reader measures the amounts of hemoglobin and hematocrit in whole blood. Hemoglobin tests are typically performed to determine the RBC count, the severity of anemia, hematocrit, and other haematological factors. It is widely utilized during blood donations and key decisions such as blood transfusions. HbX works with Spectrophotometry Scattered compensation Technology for accurate and quick results Results will be retrieved with in less than 3 seconds after sample reading starts Sample Required: 7ul Capillary or Venous blood Three Step procedure makes HbX more convenient to use CV value will be less than 1.5 % 6 Hours Battery Backup makes it a hand equipment 2000 Data storage capacity Micro Fluidic cuvettes with 2 year Shelf life

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Vitamin D Rapid Quantitative Test along with Finecare™ FIA Meter is a fluorescence immunoassay quantitative determination of total 25(OH) D2/D3 level in human serum or plasma. Results are to be used in conjunction with other clinical and laboratory data to assist the clinician in the assessment of vitamin D sufficiency. STORAGE AND STABILITY 1. Store at 4°C~30°C up to the expiration date. 2. The solid marker bottle can be stored at 2°C~8°C for 28 days after being reconstituted. 3. Do not remove the device from the pouch until ready to use. The Test Cartridges should be used within 1 hour once opened.

Send Message
product image
Immunoassay Reagents

INTENDED USE The Finecare™ 2019-nCoV lgM/lgG Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for qualitative detection of IgG and IgM antibodies of novel coronaviruses (2019-nCoV) in human whole blood, serum and plasma specimen. Clinically, the test is to be used as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by 2019-nCoV. The test provides preliminary test results. Negative results cannot exclude the possibility of 2019-nCoV infection and they cannot be used as the sole basis for treatment or other management decision. STORAGE AND STABILITY 1. Store at 4-30°C in the sealed pouch up to the expiration date printed on the package. Do not freeze. 2. The test device should be used within 1 hour after taking out from the foil envelope. 3. Keep away from sunlight, moisture and heat. 4. Kit contents are stable until the expiration date printed on the outer box.

Send Message
product image
Rapid Test

Intended Use The 4th Generation HIV TRI-DOT + Ag test is a visual, rapid, sensitive and accurate immunoassay for the differential detection of HIV-1 p24 antigen and HIV-1 & HIV-2 antibodies (IgM,IgG & IgA) in Human Serum or Plasma. The test is a screening test for p24 antigen (HIV-1), anti-HIV-1 & anti-HIV-2 and is for in vitro diagnostic use only. It is intended for screening of blood donors or other individuals at risk for HIV-1 & HIV-2 infection and for clinical diagnostic testing. Salient Features Rapid visual test ,based on enzyme immuno assay & Flow Through Technology. Rapid test for simultaneous and differential detection of p24 Antigen & antibodies for HIV on the same device. Ideal for Blood screening: detects sero-negative HIV Cases. Use of gp-41, C terminus of gp120 for HIV-1 antibodies & gp-36 for HIV -2 antibodies. Detection of Group ‘0’ & subtype ‘C’ of HIV-1, which is most prevalent in India. Unique washing steps for clear Interpretation of Results. Evaluated by National Institute of Biologicals- 100 % Sensitivity & 100 % Specificity. Long Shelf life: 15 months at 2-8° C.

Send Message
product image
Rapid Test

Intended Use Advantage Malaria PAN+Pf Card is a rapid, visual and sensitive immunoassay for the qualitative diagnosis of infection with P.falciparum and other Plasmodium species (P.falciparum/P.vivax/P.malariae/P.ovale) in human whole blood only. Salient Features Detects P.f. (HRP-2) and PAN(pLDH) Individually pouched Single tests- Practical & Safe Infection free- See through Device Easy to perform test Easy to interpret Colour bands Results within 20 minutes Sensitivity of 100% & Specificity of 99.80% Longer shelf life -30 months, storage at 4-30° C

Send Message

Still searching for
other respiratory disorders?