Jaipur
+918529833535

'other ingredients'

Items tagged with 'other ingredients'

product image
Glycohemoglobin Analysis

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 100 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Rapid Test

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 10 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % Safety Information Important saftey handling: • Wash hands thoroughly, with soap and water before and after testing • Never use fingerstick devices for more than one person. Use auto disabling, single use fingerstick devices for assisted monitoring of blood glucose. Storage & Handling: • Store the strips in their original vial in a cool, dry place between: 0°-50° C (32° and 122° F). Keep away from direct sunlight and heat. • Do not refrigerate or freeze. • When you take a strip from the vial, close the cap immediately. Use the strip immediately. • Check the expiry date on the vial. If the expiry date has passed, do not use the strips. Important health-related information: • Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult your physician or doctor immediately. • Test results below 70 mg/dL. mean low blood glucose (hypoglycemia). • Test results greater than 180 mg/dL mean high blood glucose (hyperglycemia). • If you get results below 70 mg/dL or above 180 mg/dL and do not have symptoms of hypoglycemia or hyperglycemia, repeat the test. If you have symptoms or continue to get results that fall below 70 mg/dL or above 180 mg/dL, follow the treatment/advice of your healthcare professional. • If you are experiencing symptoms that are not consistent with your blood glucose test and you have followed all instructions described in the Xpress Gluco owner’s booklet, consult your healthcare professional Other Info UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
HEMOGLOBIN METER

Mispa HbX Portable Haemoglobin Analyzer Overview Mispa HbX , Smart Haemoglobin analyzer is a symbol of advanced point of care equipment with modern technology and convenience, designed to deliver high accuracy, quality results with least turnaround time and low maintenance. Best in Class Hemoglobin Meter Mispa HbX, the Smart Haemoglobin Analyzer, is the best example of an advanced point-of-care hemoglobin reader with modern technology. It is easy to use and designed to deliver accurate, high-quality results with the shortest turnaround time and minimal maintenance. This digital Hb meter is one of the best hemoglobin meters available. Working of A Hemoglobin Meter or a hemoglobin reader A hemoglobin meter or a hemoglobin reader measures the amounts of hemoglobin and hematocrit in whole blood. Hemoglobin tests are typically performed to determine the RBC count, the severity of anemia, hematocrit, and other haematological factors. It is widely utilized during blood donations and key decisions such as blood transfusions. HbX works with Spectrophotometry Scattered compensation Technology for accurate and quick results Results will be retrieved with in less than 3 seconds after sample reading starts Sample Required: 7ul Capillary or Venous blood Three Step procedure makes HbX more convenient to use CV value will be less than 1.5 % 6 Hours Battery Backup makes it a hand equipment 2000 Data storage capacity Micro Fluidic cuvettes with 2 year Shelf life

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Vitamin D Rapid Quantitative Test along with Finecare™ FIA Meter is a fluorescence immunoassay quantitative determination of total 25(OH) D2/D3 level in human serum or plasma. Results are to be used in conjunction with other clinical and laboratory data to assist the clinician in the assessment of vitamin D sufficiency. STORAGE AND STABILITY 1. Store at 4°C~30°C up to the expiration date. 2. The solid marker bottle can be stored at 2°C~8°C for 28 days after being reconstituted. 3. Do not remove the device from the pouch until ready to use. The Test Cartridges should be used within 1 hour once opened.

Send Message
product image
Immunoassay Reagents

INTENDED USE The Finecare™ 2019-nCoV lgM/lgG Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for qualitative detection of IgG and IgM antibodies of novel coronaviruses (2019-nCoV) in human whole blood, serum and plasma specimen. Clinically, the test is to be used as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by 2019-nCoV. The test provides preliminary test results. Negative results cannot exclude the possibility of 2019-nCoV infection and they cannot be used as the sole basis for treatment or other management decision. STORAGE AND STABILITY 1. Store at 4-30°C in the sealed pouch up to the expiration date printed on the package. Do not freeze. 2. The test device should be used within 1 hour after taking out from the foil envelope. 3. Keep away from sunlight, moisture and heat. 4. Kit contents are stable until the expiration date printed on the outer box.

Send Message
product image
Rapid Test

Intended Use The 4th Generation HIV TRI-DOT + Ag test is a visual, rapid, sensitive and accurate immunoassay for the differential detection of HIV-1 p24 antigen and HIV-1 & HIV-2 antibodies (IgM,IgG & IgA) in Human Serum or Plasma. The test is a screening test for p24 antigen (HIV-1), anti-HIV-1 & anti-HIV-2 and is for in vitro diagnostic use only. It is intended for screening of blood donors or other individuals at risk for HIV-1 & HIV-2 infection and for clinical diagnostic testing. Salient Features Rapid visual test ,based on enzyme immuno assay & Flow Through Technology. Rapid test for simultaneous and differential detection of p24 Antigen & antibodies for HIV on the same device. Ideal for Blood screening: detects sero-negative HIV Cases. Use of gp-41, C terminus of gp120 for HIV-1 antibodies & gp-36 for HIV -2 antibodies. Detection of Group ‘0’ & subtype ‘C’ of HIV-1, which is most prevalent in India. Unique washing steps for clear Interpretation of Results. Evaluated by National Institute of Biologicals- 100 % Sensitivity & 100 % Specificity. Long Shelf life: 15 months at 2-8° C.

Send Message
product image
Rapid Test

Intended Use Advantage Malaria PAN+Pf Card is a rapid, visual and sensitive immunoassay for the qualitative diagnosis of infection with P.falciparum and other Plasmodium species (P.falciparum/P.vivax/P.malariae/P.ovale) in human whole blood only. Salient Features Detects P.f. (HRP-2) and PAN(pLDH) Individually pouched Single tests- Practical & Safe Infection free- See through Device Easy to perform test Easy to interpret Colour bands Results within 20 minutes Sensitivity of 100% & Specificity of 99.80% Longer shelf life -30 months, storage at 4-30° C

Send Message
product image
Rapid Test

Intended Use HIV Ag & Ab Card (4th Generation) is a visual, rapid qualitative and sensitive solid phase immunochromatographic assay for the differential detection of HIV-1 p24 Antigen and Antibodies (IgM, IgG & IgA) to HIV-1& HIV-2 in Human Serum/ Plasma/ Whole blood (collected by venipuncture or Fingerprick). The test is a screening test for p24 antigen (HIV-1) and HIV antibodies (anti-HIV-1 & anti-HIV-2) and is for in vitro diagnostic use only. It is intended for screening of blood donors or other individuals at risk for HIV-1 & HIV-2 infection and for clinical diagnostic testing. It is a screening test for p24 antigen (HIV-1) and HIV antibodies (anti-HIV-1 & anti-HIV-2). The test is for in vitro diagnostic use only and is intended for screening of blood donors or others individuals at risk for HIV-1 and/or HIV-2 infection and for clinical diagnostic testing. Salient Features • Finger prick, rapid, visual and qualitative Immunoassay. • 4TH Generation Rapid test for differential detection of p24 Antigen & antibodies for HIV in serum/plasma /whole blood. • Ideal for Blood screening, detects sero-negative HIV Cases. • Use of gp-41, C terminus of gp120 for HIV-1 , gp-36 for HIV -2 antibodies and Anti-p24 for HIV p24 Ag detection. • Detection of Group ‘0’ & subtype ‘C’ of HIV-1, which is most prevalent in India. • Based on Immunochromatography Technique. • See through device for easy interpretation of results. • Sensitivity : 100 % & Specificity: 100% • Analytical Sensitivity of HIV p24 Ag : 100 IU/ml (traceable to p24 Antigen NIBSC Standard, U.K. Code No. 90/636) • Long Shelf life 30 months at 2-30°C • Convenient pack size: 25 T.

Send Message

Still searching for
other ingredients?