Jaipur
+918529833535

'oscar preg sign test device'

Items tagged with 'oscar preg sign test device'

product image
Rapid Test

The OnSite hCG Combo Rapid Test is a lateral flow chromatographic immunoassay for the early detection of pregnancy, by providing a quick direct visual test for the placental hormone, hCG in human serum, plasma and urine. It can be performed within 5-10 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite hCG Combo Rapid Test is not intended for quantitative results, nor for over the counter (OTC) sales. It is intended to meet all requirements for yielding rapid, easily read, qualitative results for the purpose of early pregnancy detection via assay of hCG, a placental hormone that may be present in human serum, plasma or urine. The hCG detection limit the OnSite hCG Combo Rapid Test is 12.5 mIU/mL in serum or plasma specimen, and 25 mIU/mL in urine specimen. It is designed for professional use only, and provides only preliminary analytical data. For a final diagnosis of pregnancy, a more specific alternative clinical method must be used to obtain a confirmed analytical result. Clinical accuracy: In comparison with a reference chemiluminecsence or ELISA, hCG detection is 100% sensitivity and 100% specificity in urine specimens 100% sensitivity and 99.5% specificity in serum specimens Analytical sensitivity: 100% positive detection rate at 12.5 mIU/mL in serum/plasma specimens and 100% positive detection rate at 25 mIU/mL in urine specimens Analytical specificity: no cross reactivity with 1,000 mIU/mL human luteinizing hormone (hLH), 1,000 mIU/mL human follicle stimulating hormone (hFSH), and 1,000 mIU/mL human thyroid stimulating hormone (hTSH) Dose hook effect: no dose hook effect was observed for hCG at concentrations up to 500,000 mIU/mL in urine specimens Interference: No interference was seen with 35 biological and chemical analytes commonly found in OTC, prescriptions or abuse drugs in urine or serum/plasma specimens, as well as pH 4-9 (see detail in the package insert) Shelf life: 24 month Kit box package: 1. Individually sealed foil pouches containing; a. One dip strip device b. One desiccant 2. One package insert (instruction for use) Tube package: 1. Strip Package 2. One desiccant 3. One package insert (instruction for use) CTK Products at a Glance Drugs.com: Overview of Human Chorionic Gonadotropin Inserts

Send Message
product image
Rapid Test

The OnSite hCG Combo Rapid Test is a lateral flow chromatographic immunoassay for the early detection of pregnancy, by providing a quick direct visual test for the placental hormone, hCG in human serum, plasma and urine. It can be performed within 5-10 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite hCG Combo Rapid Test is not intended for quantitative results, nor for over the counter (OTC) sales. It is intended to meet all requirements for yielding rapid, easily read, qualitative results for the purpose of early pregnancy detection via assay of hCG, a placental hormone that may be present in human serum, plasma or urine. The hCG detection limit of the OnSite hCG Combo Rapid Test is 12.5 mIU/mL in serum or plasma specimen, and 25 mIU/mL in urine specimen. It is designed for professional use only, and provides only preliminary analytical data. For a final diagnosis of pregnancy, a more specific alternative clinical method must be used to obtain a confirmed analytical result. Clinical accuracy: In comparison with a reference chemiluminecsence or ELISA, hCG detection is 100% sensitivity and 100% specificity in urine specimens 100% sensitivity and 99.1% specificity in serum specimens Analytical sensitivity: 100% positive detection rate at 12.5 mIU/mL in serum/plasma specimens and 100% positive detection rate at 25 mIU/mL in urine specimens Analytical specificity: no cross reactivity with 1,000 mIU/mL human luteinizing hormone (hLH), 1,000 mIU/mL human follicle stimulating hormone (hFSH), and 1,000 mIU/mL human thyroid stimulating hormone (hTSH) Dose hook effect: no dose hook effect was observed for hCG at concentrations up to 500,000 mIU/mL in urine specimens Interference: No interference was seen with 35 biological and chemical analytes commonly found in OTC, prescriptions or abuse drugs in urine or serum/plasma specimens, as well as pH 4-9 (see detail in the package insert) Shelf life: 24 month Individually sealed foil pouches containi a. One cassette device b. One plastic dropper c. One desiccant One package insert (instruction for use) CTK Products at a Glance Drugs.com: Overview of Human Chorionic Gonadotropin Inserts CATALOG # PRODUCT QUANTITY SPECIMEN R1001C hCG Combo Rapid Test CE 30/kit S/Urine OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT QUANTITY SPECIMEN R1001S hCG Combo Rapid Test (Strip) CE 50/kit, 100/kit S/Urine

Send Message
product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message
product image
Instruments

CLIAlyzer is an intuitive bench-top chemiluminescent analyzer allowing for quick operation and use. CLIAlyzer delivers results when paired with our RapidLight tests. Laboratories can run multiple specimen options and six tests simultaneously, providing up to 24 test results per hour. The CLIAlyzer is an in vitro diagnostic device used for the quantitative determination of concentrations of various analytes found in serum, whole blood, or plasma specimens. Compact size Automated walkaway system Easy operation with 7-inch touchscreen Barcode reader reduces manual entry errors Results on screen, on a printout, or uploaded to database Storage capacity of 100,000 test results Laboratory Information System (LIS) connectivity High accuracy and precision with highly sensitive PMT for signal detection Assay results as quick as 15 minutes (test-specific) Compatibility with whole blood, serum, plasma (test-specific) Six cartridge positions Automatic detection of test parameter through barcode on test strip, thus reducing any user-related errors Low maintenance analyzer due to no storage of buffer System: Automated chemiluminescence system Interface: 7-inch color touch screen Methodology: Magnetic particle-based assay with chemiluminescence detection Reaction mode: Batch mode Sample type: Serum, plasma, whole blood (test specific) Sample positions: 6 Volume: 420mm x 610mm x 321mm Weight: 35kg Connectivity: USB, RS232, LIS connection Barcode Scanner: 1-D & 2-D barcode

Send Message
product image
Glucometer

MICROLET®NEXT Lancing Device NEW SIMPLY IMPROVED The easy-to-use MICROLET®NEXT lancing device is designed to help minimize pain so you can test with confidence. New and Improved Features to Love: Locking endcap helps prevent accidental lancing 5 clearly visible depth settings Smooth-gliding mechanism to minimize noise Easy-to-use lancet ejector Uses silicone-coated MICROLET®lancets for smooth gliding into the skin Uses MICROLET®Lancets Silicone coated for easier, gentler testing Available in Seven (7) vibrant colours to allow colour coded testing Coloured lancets give you visual feedback to remind you to change your lancets more often

Send Message
product image
Glucometer

Contour Plus One Blood Glucose Monitoring System is designed to help measure blood sugar levels in the body. The device helps in diabetes management and gives accurate results within seconds. Moreover, it has a smart light feature that indicates critical cases of high or low blood sugar levels. Uses: It is made to help measure blood sugar levels in the body. Product Specifications and Features: The CONTOUR®PLUS ONE meter and CONTOUR™DIABETES app seamlessly connect via Bluetooth® technology to help manage your diabetes Contains a smart light feature that indicates critical cases of high or low blood sugar levels This diabetes monitor gives fast and easy-to-read results (5-second countdown) Comes with a memory that stores up to 800 results Item Weight: 290 g 1 CR2 batteries required (included) 1 vial of 25 strips along with the pack The kit includes: the meter, carrying case, microlet next lancing device/ 5 colored microlet lancets, quick reference guide, user guide, and warranty card Directions For Use: Insert a test strip, apply a small blood sample, and read your blood glucose result on the large display. Safety Information: Read the label carefully before use Store in a cool dry place away from direct sunlight Keep away from children For Expiry of this product click here or call on 8287254760. Make an enquiry for this product

Send Message
product image
Rapid Test

Buy AccuTest Vitamin D Rapid Card Test (10 Tests) Online from Accurex. The Vitamin D test kit consists of 25 AccuTest Vitamin D individually packed test, devices in foil pouches, 25 pipettes for collecting 10 ul of whole blood, 25 lancets, 1 Buffer Vial (Buffer 5 mL) with stabilizers and, thimerosal, 1 Package Insert. Vitamin D Fast test kit is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This Vitamin D test provides a preliminary screening test result. INTENDED USE AccuTest Vitamin D is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This assay provides only a preliminary screening test result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. The performance characteristics of this assay have not been established in a pediatric population. PRINCIPLE AccuTest Vitamin D is based on the principle of a competitive enzyme immunoassay. The assay is based on the competition for 25-OH Vitamin D present in blood/serum sample and Vitamin D present on the test line for fixed number of antibody-gold conjugate. Depending upon the concentration of Vitamin D in blood/serum, there will be free antibody-gold conjugate molecules that will bind to Vitamin D on the test strip and will show a colored line in the test line zone. A control line is present in the test window to work as procedural control. PRECAUTIONS 1. For in vitro diagnostic use only. 2. The test is designed for use with human blood/serum only. 3. Reagents must be at room temperature (8⁰C – 30 ⁰C). 4. Do not use if test device packaging is open or damaged. 5. Do not use the product beyond expiration date. 6. Handle all specimens as potentially infectious. Proper handling and disposal methods should be used according to good laboratory practices. 7. Read test results for 10 minutes as required. Results may deteriorate and may not be consistent after 10 minutes. 8. In order to avoid variable results, mix the blood sample thoroughly. 9. A serum sample subjected to repeated freeze thaw cycles may give variable results Direction for Use PROCEDURE 1. Remove the cassette from the sealed pouch and place it on a hard flat surface with the view window facing up (use the cassette as soon as possible). 2. Using a micropipette, add 10 µl of whole blood or 5ul of serum sample directly into the rectangular specimen well (marked with Red drop) of the cassette. 3. Add 3 full drops of Buffer into the square buffer well of the cassette (Do not move the cassette after addition of buffer). 4. Let the cassette sit for 10 minutes and read your results immediately. Results may deteriorate after the 10 minute mark. Other Info STORAGE AND STABILITY The test device should be stored at 8 ⁰C – 30 ⁰C and will be stable until the expiration date stated on the package. The product is humidity sensitive and should be used immediately after being open. INTERPRETATION OF RESULTS Match the color of the test line with the chart provided.

Send Message

Still searching for
oscar preg sign test device?